Feasibility and speed of insertion of seven supraglottic airway devices under simulated airway conditions

被引:20
作者
Robak, Oliver [1 ]
Leonardelli, Marco
Zedtwitz-Liebenstein, Konstantin [2 ]
Ruetzler, Kurt [3 ]
Schuster, Ernst [4 ]
Vaida, Sonia [5 ]
Salem, Ramez [6 ]
Frass, Michael
机构
[1] Med Univ Vienna, Dept Med 1, Intens Care Unit, A-1090 Vienna, Austria
[2] Vienna Hosp Assoc, Head Off, Vienna, Austria
[3] Med Univ Vienna, Dept Anesthesiol & Gen Intens Care, A-1090 Vienna, Austria
[4] Med Univ Vienna, Ctr Med Stat Informat & Intelligent Syst, A-1090 Vienna, Austria
[5] Penn State Milton S Hershey Med Ctr, Dept Anesthesiol, Hershey, PA USA
[6] Advocate Illinois Masonic Med Ctr, Dept Anesthesiol, Chicago, IL USA
关键词
emergency medicine; manikin; supraglottic airway; ESOPHAGEAL-TRACHEAL COMBITUBE(TM); RESUSCITATION-COUNCIL GUIDELINES; ACUTELY ILL PATIENT; HEALTH-CARE; MANAGEMENT; MANNEQUIN; INTUBATION; PARAMEDICS; SKILLS;
D O I
10.2310/8000.2012.120658
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: Endotracheal intubation (ETI) is considered the gold standard for protecting the airway. Alternative devices for airway protection have been developed that can be used by untrained personnel, by those with less experience, and for when ETI is not possible. The main goals of our study were to evaluate the success rate and speed of insertion of different supraglottic airway devices and to determine whether the devices could be properly inserted under simulated critical conditions. Methods: Fifty medical students used an airway simulation trainer (Laerdal SimMan 3G) to assess the success rate and time used to insert seven different supraglottic airway devices under simulated physiologic and pathologic conditions in two different runs. Results: Although all airway devices could be inserted without problems, only the Combitube and the EasyTube could be successfully inserted in simulations of trismus, limited mobility of the cervical spine, or a combination of pathologic conditions such as trismus plus limited mobility of the spine and trismus plus tongue edema. The insertion time was significantly longer with LMA Unique, Fastrach, and I-Gel devices in both the first and second runs. Conclusion: The Combitube and the EasyTube were most easily inserted under simulated conditions such as trismus, limited mobility of the cervical spine, and combined pathologic conditions. Although all devices are useful for establishing an airway by nontrained medical students in standard simulations, we suggest that the Combitube and the EasyTube may offer advantages in difficult airway situations.
引用
收藏
页码:330 / 334
页数:5
相关论文
共 20 条
[1]   A comparison of the proseal laryngeal mask airway™, the laryngeal tube S®o and the oesophageal-tracheal combitube™ during routine surgical procedures [J].
Bein, B ;
Carstensen, S ;
Gleim, M ;
Claus, L ;
Tonner, PH ;
Steinfath, M ;
Scholz, J ;
Dörges, V .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2005, 22 (05) :341-346
[2]   Airway management by paramedics using endotracheal intubation with a laryngoscope versus the oesophageal tracheal Combitube™ and EasyTube™ on manikins:: A randomised experimental trial [J].
Bollig, Georg ;
Lovhaug, Sigurd Waage ;
Sagen, Oystein ;
Svendsen, Martin Veel ;
Steen, Petter Andreas ;
Wik, Lars .
RESUSCITATION, 2006, 71 (01) :107-111
[3]   ADVERSE RESPIRATORY EVENTS IN ANESTHESIA - A CLOSED CLAIMS ANALYSIS [J].
CAPLAN, RA ;
POSNER, KL ;
WARD, RJ ;
CHENEY, FW .
ANESTHESIOLOGY, 1990, 72 (05) :828-833
[4]   Prehospital advanced airway management by ambulance technicians and paramedics: is clinical practice sufficient to maintain skills? [J].
Deakin, C. D. ;
King, P. ;
Thompson, F. .
EMERGENCY MEDICINE JOURNAL, 2009, 26 (12) :888-891
[5]   Performance of supraglottic airway devices and 12 month skill retention: A randomized controlled study with manikins [J].
Fischer, Henrik ;
Hochbrugger, Eva ;
Fast, Andrea ;
Hager, Helmut ;
Steinlechner, Barbara ;
Koinig, Herbert ;
Eisenburger, Philip ;
Frantal, Sophie ;
Greif, Robert .
RESUSCITATION, 2011, 82 (03) :326-331
[6]   Students insert the laryngeal tube quicker and more often successful than the esophageal-tracheal combitube in a manikin [J].
Hueter, Lars ;
Schwarzkopf, Konrad ;
Roediger, Joerg ;
Preussler, Niels P. ;
Schreiber, Torsten .
RESUSCITATION, 2009, 80 (08) :930-934
[7]   Evaluation of four airway training manikins as patient simulators for the insertion of eight types of supraglottic airway devices [J].
Jackson, K. M. ;
Cook, T. M. .
ANAESTHESIA, 2007, 62 (04) :388-393
[8]   Emergency intubation for acutely ill and injured patients [J].
Lecky, F. ;
Bryden, D. ;
Little, R. ;
Tong, N. ;
Moulton, C. .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2008, (02)
[9]   Use of the intubating laryngeal mask airway by medical and nonmedical personnel [J].
Levitan, RM ;
Ochroch, EA ;
Stuart, S ;
Hollander, JE .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2000, 18 (01) :12-16
[10]   The assessment and treatment of the acutely ill patient - the role of the patient simulator as a teaching tool in the undergraduate programme [J].
MacDowall, Jennifer .
MEDICAL TEACHER, 2006, 28 (04) :326-329