Uncertainty of determination of palladium in road dust sample by inductively coupled plasma mass spectrometry

被引:8
作者
Polák, J [1 ]
Mestek, O [1 ]
Suchánek, M [1 ]
机构
[1] Inst Chem Technol, CR-16628 Prague 6, Czech Republic
关键词
palladium; isotope dilution; mass spectrometry; soils; uncertainty;
D O I
10.1007/s00769-005-0057-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of palladium in a road dust sample taken close to the highway (w (Pd)=450 ng g(-1)) was carried out by the ICP-MS method after sample decomposition by aqua-regia. Analyses were evaluated by two methods: external calibration accompanied with mathematical correction of spectral interferences (EC) and isotope dilution measurement after separation of Pd by extraction to dibutyl sulfide solution (ID). In both cases, the uncertainties and accuracy of results were investigated. Although in the case of ideally homogeneous sample the repeatability of EC results (11 ng g(-1)Pd) was somewhat lower than those of ID results (16 ng g(-1)Pd), the uncertainties of results of both techniques were almost the same and they reached the level of 19 ng g(-1)Pd. The main uncertainty source of the EC method is represented by the correction of spectral interferences. In case of real non-homogeneous sample, the main uncertainty component represents the soil sampling. The uncertainty of results (approx. 75 ng g(-1)Pd) only slightly exceeded the repeatability (approx. 70 ng g(-1)Pd). The accuracy of results was proven by analyses of CRM TDB-1 Diabas Rock (in case of ID) and by the standard addition method (in case of EC).
引用
收藏
页码:627 / 632
页数:6
相关论文
共 12 条
[1]  
AMBROSETTI P, 1979, ATOM ABSORPT NEWSL, V18, P38
[2]  
[Anonymous], QUANTIFYING UNCERTAI
[3]   Atomic weights of the elements 1999 [J].
Coplen, TB .
PURE AND APPLIED CHEMISTRY, 2001, 73 (04) :667-683
[4]  
JARVIS KE, 1995, HDB INDUCTIVELY COUP
[5]   Impact of automobile emissions on the levels of platinum and lead in Accra, Ghana [J].
Kylander, ME ;
Rauch, S ;
Morrison, GM ;
Andam, K .
JOURNAL OF ENVIRONMENTAL MONITORING, 2003, 5 (01) :91-95
[6]   Computer simulation of the uncertainty of analytical results [J].
Mestek, O ;
Suchánek, M ;
Koplík, R ;
Fingerová, H ;
Curdová, E .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (03) :203-207
[7]   Bioaccumulation of palladium, platinum and rhodium from urban particulates and sediments by the freshwater isopod Asellus aquaticus [J].
Moldovan, M ;
Rauch, S ;
Gómez, M ;
Palacios, MA ;
Morrison, GM .
WATER RESEARCH, 2001, 35 (17) :4175-4183
[8]  
PRIHODA J, 1982, JAD ENERG, V28, P90
[9]   Critical assessment of platinum group element determination in road and urban river sediments using ultrasonic nebulisation and high resolution ICP-MS [J].
Rauch, S ;
Motelica-Heino, M ;
Morrison, GM ;
Donard, OFX .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (04) :329-334
[10]   Isotopic compositions of the elements 1997 [J].
Rosman, KJR ;
Taylor, PDP .
PURE AND APPLIED CHEMISTRY, 1998, 70 (01) :217-235