Note: Magnetic noise from the inner wall of a magnetically shielded room

被引:8
|
作者
Khan, Sheraz [1 ,2 ]
Cohen, David [2 ,3 ,4 ]
机构
[1] Harvard Univ, Sch Med, Massachusetts Gen Hosp, Dept Neurol, Boston, MA 02129 USA
[2] Harvard Univ, MIT, Massachusetts Gen Hosp, AA Martinos Ctr Biomed Imaging, Boston, MA 02129 USA
[3] Harvard Univ, Sch Med, Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02129 USA
[4] MIT, Francis Bitter Magnet Lab, Cambridge, MA 02139 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2013年 / 84卷 / 05期
关键词
MAGNETOENCEPHALOGRAPHY;
D O I
10.1063/1.4802845
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We measured the thermal magnetic noise generated by the inner high-permeability wall of a magnetically shielded room. This room houses a magnetoencephalogram (MEG), which contains 102 "small" identical magnetometers. For the measurement, we created two large magnetometers by summing the outputs of 46 magnetometers equally on the helmet's left and right side, to look at the summed noise of the right and left vertical walls. From these summed outputs, we calculated the rms noise amplitude due to all six walls at the MEG location to be similar to 0.5 f T/root Hz at 100 Hz, only slowly rising with lower frequency. This is well below the system noise of each small MEG magnetometer, hence is negligible for the MEG. (C) 2013 Author(s). All article content, except where otherwise noted, is licensed under a Creative Commons Attribution 3.0 Unported License.
引用
收藏
页数:3
相关论文
共 50 条
  • [41] Study of Spatial Filter for Magnetocardiography Measurements without a Magnetically Shielded Room
    Ogata, Yuji
    Tanaka, Takeshi
    Hata, Yoshiyuki
    Kakinuma, Bunichi
    Ueda, Tomoaki
    Kobayashi, Koichiro
    ADVANCED BIOMEDICAL ENGINEERING, 2019, 8 : 170 - 176
  • [42] Active Compensation Method for Magnetic Interference in Magnetically Shielded Room Based on Improved Linear Extended State Observer
    Tian, Pengtao
    Le, Yun
    Zhao, Fengwen
    Tian, Kangqi
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
  • [43] Design Method for Realization of Open-Type Magnetically Shielded Room Composed of Magnetic Square Cylinders for MRI
    Hirosato, Shigetaka
    Yamazaki, Keita
    Haraguchi, Yu
    Gao, Yanhui
    Muramatsu, Kazuhiro
    Haga, Akira
    Kamata, Kiyotaka
    Sasaki, Hitomi
    Kobayashi, Koichiro
    IEEE TRANSACTIONS ON MAGNETICS, 2011, 47 (05) : 954 - 957
  • [44] Open-Type Magnetically Shielded Room Combined With Square Cylinders Made of Magnetic and Conductive Materials for MRIs
    Yamazaki, Keita
    Hirosato, Shigetaka
    Kamata, Kiyotaka
    Muramatsu, Kazuhiro
    Kobayashi, Koichiro
    Haga, Akira
    IEEE TRANSACTIONS ON MAGNETICS, 2008, 44 (11) : 4183 - 4186
  • [45] Design and Construction Method of an Open-Type Magnetically Shielded Room for MRI Composed of Magnetic Square Cylinders
    Hirosato, Shigetaka
    Yamazaki, Keita
    Haraguchi, Yu
    Muramatsu, Kazuhiro
    Haga, Akira
    Kamata, Kiyotaka
    Kobayashi, Koichiro
    Matsuura, Atsuo
    Sasaki, Hitomi
    IEEE TRANSACTIONS ON MAGNETICS, 2009, 45 (10) : 4636 - 4639
  • [46] Generating a highly uniform magnetic field inside the magnetically shielded room of the n2EDM experiment
    Abel, C.
    Ayres, N. J.
    Ban, G.
    Bison, G.
    Bodek, K.
    Bondar, V.
    Bouillaud, T.
    Bowles, D. C.
    Caratsch, G. L.
    Chanel, E.
    Chen, W.
    Chiu, P. -j.
    Crawford, C.
    Dechenaux, B.
    Doorenbos, C. B.
    Emmenegger, S.
    Ferraris-Bouchez, L.
    Fertl, M.
    Flaux, P.
    Fratangelo, A.
    Goupilliere, D.
    Griffith, W. C.
    Grujic, Z.
    Hoehl, D.
    Kasprzak, M.
    Kirch, K.
    Kletzl, V.
    Komposch, S. V.
    Koss, P. A.
    Krempel, J.
    Lauss, B.
    Lefort, T.
    Lejuez, A.
    Li, R.
    Meier, M.
    Menu, J.
    Michielsen, K.
    Mullan, P.
    Mullins, A.
    Naviliat-Cuncic, O.
    Pais, D.
    Piegsa, F. M.
    Pignol, G.
    Quemener, G.
    Rawlik, M.
    Rebreyend, D.
    Rienaecker, I.
    Ries, D.
    Roccia, S.
    Rozpedzik, D.
    EUROPEAN PHYSICAL JOURNAL C, 2025, 85 (02):
  • [47] Evaluation of a high-performance magnetically shielded room for biomagnetic measurement
    Harakawa, K
    Kajiwara, G
    Kazami, K
    Ogata, H
    Kado, H
    IEEE TRANSACTIONS ON MAGNETICS, 1996, 32 (06) : 5256 - 5260
  • [48] Design and Optimization of Biplanar Coils for Active Magnetic Compensation System Inside the MINI-Magnetically Shielded Room
    Tian, Kangqi
    Zhang, Xu
    Shi, Minxia
    Yang, Jianzhi
    Cao, Fuzhi
    Wang, Fulong
    Shi, Ziyang
    Wang, Kun
    Zheng, Shiqiang
    Liu, Gang
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2025, 72 (01) : 1065 - 1075
  • [50] Non-uniform dynamic magnetic field compensation for a lightweight magnetically shielded room based on distributed differential coils
    Zhao, Jiye
    Liu, Jiawen
    Zhou, Jiqiang
    Zhang, Lu
    Sun, Jinji
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2025, 58 (02)