Note: Magnetic noise from the inner wall of a magnetically shielded room

被引:8
|
作者
Khan, Sheraz [1 ,2 ]
Cohen, David [2 ,3 ,4 ]
机构
[1] Harvard Univ, Sch Med, Massachusetts Gen Hosp, Dept Neurol, Boston, MA 02129 USA
[2] Harvard Univ, MIT, Massachusetts Gen Hosp, AA Martinos Ctr Biomed Imaging, Boston, MA 02129 USA
[3] Harvard Univ, Sch Med, Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02129 USA
[4] MIT, Francis Bitter Magnet Lab, Cambridge, MA 02139 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2013年 / 84卷 / 05期
关键词
MAGNETOENCEPHALOGRAPHY;
D O I
10.1063/1.4802845
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We measured the thermal magnetic noise generated by the inner high-permeability wall of a magnetically shielded room. This room houses a magnetoencephalogram (MEG), which contains 102 "small" identical magnetometers. For the measurement, we created two large magnetometers by summing the outputs of 46 magnetometers equally on the helmet's left and right side, to look at the summed noise of the right and left vertical walls. From these summed outputs, we calculated the rms noise amplitude due to all six walls at the MEG location to be similar to 0.5 f T/root Hz at 100 Hz, only slowly rising with lower frequency. This is well below the system noise of each small MEG magnetometer, hence is negligible for the MEG. (C) 2013 Author(s). All article content, except where otherwise noted, is licensed under a Creative Commons Attribution 3.0 Unported License.
引用
收藏
页数:3
相关论文
共 50 条
  • [31] Modeling of Leakage Magnetic Field of Electric Machines Using Blocks With Magnetizations for Design of Magnetically Shielded Room
    Muramatsu, Kazuhiro
    Gao, Yanhui
    Moriyama, Yusuke
    Dozono, Hiroshi
    Nishino, Takaaki
    Miura, Kazuyuki
    IEEE TRANSACTIONS ON MAGNETICS, 2017, 53 (06)
  • [32] Hybrid MEG-MRI: Geometry and Time Course of Magnetic Fields Inside a Magnetically Shielded Room
    Vesanen, P. T.
    Nieminen, J. O.
    Dabek, J.
    Ilmoniemi, R. J.
    17TH INTERNATIONAL CONFERENCE ON BIOMAGNETISM ADVANCES IN BIOMAGNETISM - BIOMAG2010, 2010, 28 : 78 - 81
  • [33] Dynamic stabilisation of magnetic fields measured inside a magnetically shielded room using an external coil system
    Zhao, Jiye
    Tian, Pengtao
    Sun, Jinji
    Zhang, Haifeng
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2024, 57 (23)
  • [34] Design and Test of a Magnetic-Field Compensation Coil Without Interference With the Door of a Magnetically Shielded Room
    Liu, Xikai
    Wu, Chen
    Zhang, Lu
    Wen, Tong
    Zheng, Shiqiang
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [35] A MAGNETIC SHIELDED ROOM DESIGNED FOR MAGNETOENCEPHALOGRAPHY
    SULLIVAN, GW
    LEWIS, PS
    GEORGE, JS
    FLYNN, ER
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (04): : 765 - 770
  • [36] NEW RESULTS IN ACTIVE NOISE COMPENSATION FOR MAGNETICALLY SHIELDED ROOMS
    TERBRAKE, HJM
    HUONKER, R
    ROGALLA, H
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1993, 4 (12) : 1370 - 1375
  • [37] Magnetic Characterization of Spacecraft Equipment in a Magnetic Shielded Room
    Jin, Yinxi
    Yao, Chengzhi
    Li, Liyi
    Pan, Donghua
    Li, Junzhong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 9
  • [38] DEVELOPMENT OF A MAGNETICALLY SHIELDED ROOM EQUIPPED WITH AN AUTOMATIC DOOR FOR BIOMAGNETIC MEASUREMENTS
    Odawara S.
    Sakakibara M.
    Sakurai J.
    Adachi Y.
    AIJ Journal of Technology and Design, 2022, 28 (69) : 727 - 732
  • [39] Design of a magnetically shielded room for development of HTS SQUID systems for magnetocardiography
    Davidson, CR
    Griffin, RH
    Best, KJ
    Maltin, L
    Wolf, W
    Zhang, Y
    Bousack, H
    Soltner, H
    BIOMAG 96: PROCEEDINGS OF THE TENTH INTERNATIONAL CONFERENCE ON BIOMAGNETISM, VOLS I & II, 2000, : 35 - 38
  • [40] Numerical Modeling and Material Characterization for Multilayer Magnetically Shielded Room Design
    Canova, A.
    Freschi, F.
    Giaccone, L.
    Repetto, M.
    IEEE TRANSACTIONS ON MAGNETICS, 2018, 54 (03)