A comparison of the growth of open-set speech perception between the Nucleus 22 and Nucleus 24 cochlear implant systems

被引:0
|
作者
Waltzman, SB [1 ]
Cohen, NL [1 ]
Roland, JT [1 ]
机构
[1] NYU, Sch Med, Dept Otolaryngol, New York, NY 10016 USA
关键词
open-set speech perception; cochlear implants; deafness;
D O I
暂无
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective: To compare the short-term development of open-set speech perception between implementations of the spectral peak (SPEAK) strategy in adults using the Nucleus 22 (N22) Spectra processor and the Nucleus 24 (N24) system with the SPrint processor. Study Design: Two sets of patients with a follow-up period of 3 months were compared. Setting: This study was conducted at the New York University (NYU) Medical Center. Patients: Thirty-six profoundly hearing-impaired adults were included in this study. Intervention: Sixteen adults received the N22 cochlear implant with the Spectra speech processor and twenty adults received the N24 cochlear implant with the SPrint speech processor. Main Outcome Measures: Open-set speech perception for the patients with N22 implants was evaluated preoperatively and postoperatively using the following measures: NU-6 monosyllabic words, Iowa sentences, and CID sentences. CNC words, CUNY sentences, and HINT sentences were used to assess the patients with N24 implants. Results: Results revealed that the N22 and N24 cochlear implant recipients had significant open-set speech recognition 3 and 6 months after implantation. The apparent favorable absolute scores for the patients with N24 implants were equalized when a multivariate analysis was performed to account for their younger age at time of implantation and shorter length of deafness. Conclusions: The growth of open-set word and sentence recognition in similar between the N22 and N24 cochlear implants. Longitudinal studies are needed to determine if higher ceiling scores are present in the N24. Further exploration of monopolar versus bipolar stimulation is warranted.
引用
收藏
页码:435 / 441
页数:7
相关论文
共 9 条
  • [1] Comparison of speech perception performance between the Nucleus 24 and Nucleus 24 Contour cochlear implant systems
    Bacciu, A
    Pasanisi, E
    Vincenti, V
    Guida, M
    Barbot, A
    Berghenti, M
    Forli, F
    Berrettini, S
    Bacciu, S
    ACTA OTO-LARYNGOLOGICA, 2004, 124 (10) : 1155 - 1158
  • [2] Factors contributing to limited open-set speech perception in children who use a cochlear implant
    Gordon, KA
    Daya, H
    Harrison, RV
    Papsin, BC
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2000, 56 (02) : 101 - 111
  • [3] Open-set speech perception in congenitally deaf children using cochlear implants
    Waltzman, SB
    Cohen, NL
    Gomolin, RH
    Green, JE
    Shapiro, WH
    Hoffman, RA
    Roland, JT
    AMERICAN JOURNAL OF OTOLOGY, 1997, 18 (03) : 342 - 349
  • [4] Effects of Threshold Adjustment on Speech Perception in Nucleus Cochlear Implant Recipients
    Busby, Peter A.
    Arora, Komal
    EAR AND HEARING, 2016, 37 (03) : 303 - 311
  • [5] Speech perception performance in experienced cochlear-implant patients receiving the SPEAK processing strategy in the Nucleus Spectra-22 cochlear implant
    Parkinson, AJ
    Parkinson, WS
    Tyler, RS
    Lowder, MW
    Gantz, BJ
    JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 1998, 41 (05): : 1073 - 1087
  • [6] Speech perception with the ACE and the SPEAK speech coding strategies for children implanted with the Nucleus® cochlear implant
    Manrique, M
    Huarte, A
    Morera, C
    Caballé, L
    Ramos, A
    Castillo, C
    García-Ibáñez, L
    Estrada, E
    Juan, E
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2005, 69 (12) : 1667 - 1674
  • [7] Evaluation of bilaterally implanted adult subjects with the nucleus 24 cochlear implant systems
    Ramsden, R
    Greenham, P
    O'Driscoll, M
    Mawman, D
    Proops, D
    Craddock, L
    Fielden, C
    Graham, J
    Meerton, L
    Verschuur, C
    Toner, J
    McAnallen, T
    Osborne, J
    Doran, M
    Gray, R
    Pickerill, M
    OTOLOGY & NEUROTOLOGY, 2005, 26 (05) : 988 - 998
  • [8] Use of neural response telemetry measures to objectively set the comfort levels in the nucleus 24 cochlear implant
    King, John E.
    Polak, Marek
    Hodges, Annelle V.
    Payne, Stacy
    Telischi, Fred F.
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2006, 17 (06) : 413 - 431
  • [9] Speech perception in nucleus C124M cochlear implant users with processor settings based on electrically evoked compound action potential thresholds
    Smoorenburg, GF
    Willeboer, C
    van Dijk, JE
    AUDIOLOGY AND NEURO-OTOLOGY, 2002, 7 (06) : 335 - 347