A comparison of engineered cementitious composites versus normal concrete in beam-column joints under reversed cyclic loading

被引:129
作者
Yuan, Fang [1 ]
Pan, Jinlong [1 ]
Xu, Zhun [1 ]
Leung, C. K. Y. [2 ]
机构
[1] Southeast Univ, Key Lab Concrete & Prestressed Concrete Struct, Minist Educ, Sch Civil Engn, Nanjing 210096, Jiangsu, Peoples R China
[2] Hong Kong Univ Sci & Technol, Dept Civil & Environm Engn, Hong Kong, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
ECC; Ductility; Multiple cracking; Beam-column joints; Seismic resistance; PERFORMANCE;
D O I
10.1617/s11527-012-9890-6
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Engineered cementitious composites (ECC) are a class of high-performance fiber reinforced cementitious composite with strain hardening and multiple cracking properties. For a reinforced concrete member, substitution of conventional concrete with ECC can significantly improve the deformation characteristics in terms of reinforced composite tensile or shear strength and energy dissipation ability. In this paper, a number of RC/ECC composite beam-column joints have been tested under reversed cyclic loading to study the effect of substitution of concrete with ECC in the joint zone on the seismic behaviors of composite members. The experimental parameters include shear reinforcement ratio in the joint zone, axial load level on the column and substitution of concrete with ECC or not. According to the test results, for the specimens without shear reinforcement in the joint zone, substitution of concrete with ECC in the joint zone cannot change the brittle shear failure in the joint zone, but can significantly increase the load capacity and ductility of the beam-column joint specimens, as well as the energy dissipation ability due to high ductility and shear strength of ECC material. For the specimens with insufficient or proper shear reinforcement ratio, substitution of concrete with ECC in the joint zone can lead to failure mode change from brittle shear failure in the joint zone to a more ductile failure mode, i.e. flexural failure at the base of the beam, with increased load capacity, ductility and energy dissipation ability. Increase of axial load on column and shear reinforcement in the joint zone have little effect on seismic behaviors of the members when they failed by flexural failure at the base of beam. In a word, the substitution of concrete with ECC in the joint zone was experimentally proved to be an effective method to increase the seismic resistance of beam-column joint specimens.
引用
收藏
页码:145 / 159
页数:15
相关论文
共 20 条
  • [1] [Anonymous], EARTHQUAKE RESISTANC
  • [2] Cheung Y.N., 2004, Ph.D. Thesis
  • [3] Fischer G, 2003, ACI STRUCT J, V100, P166
  • [4] Fischer G, 2002, ACI STRUCT J, V99, P781
  • [5] Fischer G, 2002, ACI STRUCT J, V99, P104
  • [6] Fukuyama H, 1999, RILEM PROC, V6, P531
  • [7] Shear strengthening of beam-column joints
    Ghobarah, A
    Said, A
    [J]. ENGINEERING STRUCTURES, 2002, 24 (07) : 881 - 888
  • [8] Kanda T., 1998, AEDIFICATIO PUBLISHE, V3, P1477
  • [9] FRC-encased steel joist composite reams under reversed cyclic loading
    Khuntia, M
    Goel, SC
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1998, 124 (10): : 1115 - 1124
  • [10] Kim YY, 2004, ACI STRUCT J, V101, P792