Optimal reactive power dispatch of a full-scale converter based wind farm considering loss minimization

被引:45
作者
Wang, Ni [1 ]
Li, Jian [1 ]
Hu, Weihao [1 ]
Zhang, Baohua [2 ]
Huang, Qi [1 ]
Chen, Zhe [3 ]
机构
[1] Univ Elect Sci & Technol China, Sch Mech & Elect Engn, Chengdu, Sichuan, Peoples R China
[2] Envision, Shanghai, Peoples R China
[3] Aalborg Univ, Dept Energy Technol, Aalborg, Denmark
基金
中国国家自然科学基金;
关键词
Reactive power dispatch; Permanent magnet synchronous generator (PMSG); Loss minimization; Particle swarm optimization (PSO) algorithm;
D O I
10.1016/j.renene.2019.02.037
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
With the development of wind power, wind farms are required to provide reactive power to the power system. For permanent magnet synchronous generator (PMSG) based large wind farms (WF), it may be an economical way to generate reactive power using the power electronic devices inside each wind turbine (INT). In this paper, an optimal reactive power dispatch of PMSG WF is proposed to minimize the power loss. Both the losses inside WTs and the losses of transmission system are all considered. Particle swarm optimization (PSO) algorithm is adopted to find the reactive power references of each WT which makes the total loss of WF minimal. A WF with 25 5 MW PMSG WTs arranged in 5 rows and 5 columns is used in the case study. And two traditional reactive power dispatch strategies are compared comprehensively with the proposed strategy at different scenarios, the results have shown that the proposed strategy obtains lower power loss than the other two traditional strategies in all the studied cases. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:292 / 301
页数:10
相关论文
共 30 条
[1]   Differential evolution algorithm for optimal reactive power dispatch [J].
Abou El Ela, A. A. ;
Abido, M. A. ;
Spea, S. R. .
ELECTRIC POWER SYSTEMS RESEARCH, 2011, 81 (02) :458-464
[2]  
[Anonymous], 2016, GLOBAL STATUS WIND P
[3]  
[Anonymous], GEAFOL CAST RESIN TR
[4]  
[Anonymous], 2013, 5SNA 2000K451300
[5]  
[Anonymous], 2012, SIEMENS ENERGY SECTO
[6]  
[Anonymous], XLPE SUBM CABL SYST
[7]   Advanced control system of DFIG based wind generators for reactive power production and integration in a wind farm dispatching [J].
Ghennam, T. ;
Aliouane, K. ;
Akel, F. ;
Francois, B. ;
Berkouk, E. M. .
ENERGY CONVERSION AND MANAGEMENT, 2015, 105 :240-250
[8]  
Jonkman J., 2009, Report No. NREL/TP-500-38060, DOI [DOI 10.2172/947422, 10.2172/947422]
[9]   A Loss Minimization Method on a Reactive Power Supply Process for Wind Farm [J].
Jung, Seungmin ;
Jang, Gilsoo .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2017, 32 (04) :3060-3068
[10]   Towards reactive power dispatch within a wind farm using hybrid PSO [J].
Kanna, Bhaskar ;
Singh, Niwas .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2015, 69 :232-240