Heat transfer augmentation in a rectangular channel with slit rib-turbulators on two opposite walls

被引:18
|
作者
Hwang, JJ [1 ]
Liou, TM [1 ]
机构
[1] NATL TSING HUA UNIV, DEPT POWER MECH ENGN, HSINCHU 30043, TAIWAN
来源
关键词
D O I
10.1115/1.2841167
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The effect of slit ribs on heat transfer and friction in a rectangular channel is investigated experimentally. The slit ribs are arranged in-line on two opposite walls of the channel. Three rib open-area ratios (beta = 24, 37, and 46 percent), three rib pitch-to-height ratios (Pi/H = 10, 20, and 30), and two rib height-to-channel hydraulic diameter ratios (H/De = 0.081, and 0.162) are examined. The Reynolds number ranges from 10,000 to 50,000. Laser holographic interferometry is employed to measure the local heat transfer coefficients of the ribbed wall quantitatively, and observe the flow over the ribbed wall qualitatively. The results show that the slit rib has an advantage of avoiding ''hot spots.'' In addition, the heat transfer performance of the slit-ribbed channel is much better than that of the solid-ribbed channel. Semi-empirical correlations for friction and heat transfer are developed to account for rib spacings and open-area ratios. These correlations may be used in the design of turbine blade cooling passages.
引用
收藏
页码:617 / 623
页数:7
相关论文
共 50 条
  • [1] Heat transfer augmentation in a rectangular channel with slit rib-turbulators on two opposite walls
    Department of Mechanical Engineering, Chung-Hua Polytechnic Institute, Hsinchu, 30067, Taiwan
    不详
    Journal of Turbomachinery, 1997, 119 (03): : 617 - 623
  • [2] Influence of channel height on heat transfer augmentation in rectangular channels with two opposite rib-roughened walls
    Chang, SW
    Liou, TM
    Juan, WC
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2005, 48 (13) : 2806 - 2813
  • [3] Effect of rib spacing on heat transfer and friction in a rectangular channel with 45° angled rib turbulators on one/two walls
    Tanda, Giovanni
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2011, 54 (5-6) : 1081 - 1090
  • [4] Heat Transfer and Pressure Loss Characteristics Of Zig-Zag Channel with Rib-Turbulators
    Siw, Sin Chien
    Chyu, Minking K.
    Alvin, Mary Anne
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2013, VOL 3A, 2013,
  • [5] Investigation of flow and heat transfer in a rectangular channel with discrete rib-mounted heat sources on two opposite walls
    Saleh, Mohamed Ahmed
    PROCEEDINGS OF THE 5TH WSEAS INTERNATIONAL CONFERENCE ON HEAT AND MASS TRANSFER (HMT '08), 2008, : 89 - 103
  • [6] Heat Transfer in Narrow Rectangular Channels with Rib Turbulators
    Liu, Jiazeng
    Gao, Jianmin
    Gao, Tieyu
    Shi, Jiaojun
    PROGRESS IN POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2012, 354-355 : 1245 - +
  • [7] Heat transfer of rectangular narrow channel with two opposite scale-roughened walls
    Chang, SW
    Liou, TM
    Lu, MH
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2005, 48 (19-20) : 3921 - 3931
  • [8] Heat transfer in a two-pass rectangular rotating channel with 45-deg angled rib turbulators
    Azad, GS
    Uddin, MJ
    Han, JC
    Moon, HK
    Glezer, B
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2002, 124 (02): : 251 - 259
  • [9] DEVELOPING HEAT-TRANSFER IN RECTANGULAR CHANNELS WITH RIB TURBULATORS
    HAN, JC
    PARK, JS
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1988, 31 (01) : 183 - 195
  • [10] Liquid crystal heat transfer measurements in a rectangular channel with solid and slit rib
    P. K. Panigrahi
    A. Tariq
    Journal of Visualization, 2003, 6 : 407 - 416