Pulse pressure variation does not reflect stroke volume variation in mechanically ventilated rats with lipopolysaccharide-induced pneumonia

被引:7
作者
Cherpanath, Thomas G. V. [1 ]
Smeding, Lonneke [2 ]
Lagrand, Wim K. [1 ]
Hirsch, Alexander [3 ]
Schultz, Marcus J. [4 ]
Groeneveld, Johan A. B. [5 ]
机构
[1] Vrije Univ Amsterdam Med Ctr, Acad Med Ctr, Dept Intens Care Med, Amsterdam, Netherlands
[2] Vrije Univ Amsterdam Med Ctr, Inst Cardiovasc Res VU Univ Med Ctr, Amsterdam, Netherlands
[3] Vrije Univ Amsterdam Med Ctr, Dept Cardiol, Amsterdam, Netherlands
[4] Vrije Univ Amsterdam Med Ctr, Acad Med Ctr, LEICA, Amsterdam, Netherlands
[5] Vrije Univ Amsterdam Med Ctr, Dept Intens Care Med, Amsterdam, Netherlands
来源
CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY | 2014年 / 41卷 / 01期
关键词
arterial compliance; haemodynamic parameters; hypovolaemia; lipopolysaccharide; mechanical ventilation; pulse pressure; sepsis; stroke volume; TOTAL ARTERIAL COMPLIANCE; AORTIC BLOOD-FLOW; ACUTE LUNG INJURY; FLUID RESPONSIVENESS; SEPTIC SHOCK; CONTOUR ANALYSIS; TIDAL VOLUME; MODEL; DYSFUNCTION; PREDICTION;
D O I
10.1111/1440-1681.12187
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The present study examined the relationship between centrally measured stroke volume variation (SVV) and peripherally derived pulse pressure variation (PPV) in the setting of increased total arterial compliance (C-Art). Ten male Wistar rats were anaesthetized, paralysed and mechanically ventilated before being randomized to receive intrapulmonary lipopolysaccharide (LPS) or no LPS. Pulse pressure (PP) was derived from the left carotid artery, whereas stroke volume (SV) was measured directly in the left ventricle. Values of SVV and PPV were calculated over three breaths. Balloon inflation of a catheter positioned in the inferior vena cava was used, for a maximum of 30s, to decrease preload while the SVV and PPV measurements were repeated. Values of C-Art were calculated as SV/PP. Intrapulmonary LPS increased C-Art and SV. Values of SVV and PPV increased in both LPS-treated and untreated rats during balloon inflation. There was a correlation between SVV and PPV in untreated rats before (r=0.55; P=0.005) and during (r=0.69; P<0.001) occlusion of the vena cava. There was no such correlation in LPS-treated rats either before (r=-0.08; P=0.70) or during (r=0.36; P=0.08) vena cava occlusion. In conclusion, under normovolaemic and hypovolaemic conditions, PPV does not reflect SVV during an increase in C-Art following LPS-induced pneumonia in mechanically ventilated rats. Our data caution against their interchangeability in human sepsis.
引用
收藏
页码:98 / 104
页数:7
相关论文
共 50 条
  • [41] Influence of increased intra-abdominal pressure on fluid responsiveness predicted by pulse pressure variation and stroke volume variation in a porcine model
    Renner, Jochen
    Gruenewald, Matthias
    Quaden, Rene
    Hanss, Robert
    Meybohm, Patrick
    Steinfath, Markus
    Scholz, Jens
    Bein, Berthold
    CRITICAL CARE MEDICINE, 2009, 37 (02) : 650 - 658
  • [42] Correlation between Carotid and Brachial Artery Velocity Time Integral and Their Comparison to Pulse Pressure Variation and Stroke Volume Variation for Assessing Fluid Responsiveness
    Joshi, Malini
    Dhakane, Praveen
    Bhosale, Shilpushp J.
    Phulambrikar, Rutuja
    Kulkarni, Atul P.
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2022, 26 (02) : 179 - 184
  • [43] Stroke volume variation does not predict fluid responsiveness in patients with septic shock on pressure support ventilation
    Perner, A.
    Faber, T.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2006, 50 (09) : 1068 - 1073
  • [44] Pulse pressure variation as a predictor of fluid responsiveness in mechanically ventilated patients with spontaneous breathing activity: a pragmatic observational study
    Grassi, P.
    Lo Nigro, L.
    Battaglia, K.
    Barone, M.
    Testa, F.
    Berlot, G.
    HEART LUNG AND VESSELS, 2013, 5 (02) : 98 - 109
  • [45] Efficacy of using tidal volume challenge to improve the reliability of pulse pressure variation reduced in low tidal volume ventilated critically ill patients with decreased respiratory system compliance
    Xu, Yujun
    Guo, Jun
    Wu, Qin
    Chen, Junjun
    BMC ANESTHESIOLOGY, 2022, 22 (01)
  • [46] The Changes in Pulse Pressure Variation or Stroke Volume Variation After a "Tidal Volume Challenge" Reliably Predict Fluid Responsiveness During Low Tidal Volume Ventilation
    Myatra, Sheila Nainan
    Prabu, Natesh R.
    Vasishtha, Jigeeshu
    Monnet, Xavier
    Kulkarni, Atul Prabhakar
    Teboul, Jean-Louis
    CRITICAL CARE MEDICINE, 2017, 45 (03) : 415 - 421
  • [47] Meta-analysis of pulse pressure variation (PPV) and stroke volume variation (SVV) studies: a few rotten apples can spoil the whole barrel
    Frederic Michard
    Denis Chemla
    Jean-Louis Teboul
    Critical Care, 27
  • [48] Pulse pressure variation and stroke volume variation under different inhaled concentrations of isoflurane, sevoflurane and desflurane in pigs undergoing hemorrhage
    Oshiro, Alexandre Hideaki
    Otsuki, Denise Aya
    Hamaji, Marcelo Waldir M.
    Rosa, Kaleizu T.
    Ida, Keila Kazue
    Fantoni, Denise T.
    Costa Auler, Jose Otavio, Jr.
    CLINICS, 2015, 70 (12) : 804 - 809
  • [49] Meta-analysis of pulse pressure variation (PPV) and stroke volume variation (SVV) studies: a few rotten apples can spoil the whole barrel
    Michard, Frederic
    Chemla, Denis
    Teboul, Jean-Louis
    CRITICAL CARE, 2023, 27 (01)
  • [50] Comparative evaluation of stroke volume variation and inferior vena cava distensibility index for prediction of fluid responsiveness in mechanically ventilated patients
    Kaur, Kaminder Bir
    Nakra, Monish
    Mangal, Vishal
    Singh, Shalendra
    Taank, Priya
    Marwah, Vikas
    ANNALS OF CARDIAC ANAESTHESIA, 2021, 24 (03) : 327 - 332