Pulse pressure variation does not reflect stroke volume variation in mechanically ventilated rats with lipopolysaccharide-induced pneumonia

被引:7
作者
Cherpanath, Thomas G. V. [1 ]
Smeding, Lonneke [2 ]
Lagrand, Wim K. [1 ]
Hirsch, Alexander [3 ]
Schultz, Marcus J. [4 ]
Groeneveld, Johan A. B. [5 ]
机构
[1] Vrije Univ Amsterdam Med Ctr, Acad Med Ctr, Dept Intens Care Med, Amsterdam, Netherlands
[2] Vrije Univ Amsterdam Med Ctr, Inst Cardiovasc Res VU Univ Med Ctr, Amsterdam, Netherlands
[3] Vrije Univ Amsterdam Med Ctr, Dept Cardiol, Amsterdam, Netherlands
[4] Vrije Univ Amsterdam Med Ctr, Acad Med Ctr, LEICA, Amsterdam, Netherlands
[5] Vrije Univ Amsterdam Med Ctr, Dept Intens Care Med, Amsterdam, Netherlands
来源
CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY | 2014年 / 41卷 / 01期
关键词
arterial compliance; haemodynamic parameters; hypovolaemia; lipopolysaccharide; mechanical ventilation; pulse pressure; sepsis; stroke volume; TOTAL ARTERIAL COMPLIANCE; AORTIC BLOOD-FLOW; ACUTE LUNG INJURY; FLUID RESPONSIVENESS; SEPTIC SHOCK; CONTOUR ANALYSIS; TIDAL VOLUME; MODEL; DYSFUNCTION; PREDICTION;
D O I
10.1111/1440-1681.12187
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The present study examined the relationship between centrally measured stroke volume variation (SVV) and peripherally derived pulse pressure variation (PPV) in the setting of increased total arterial compliance (C-Art). Ten male Wistar rats were anaesthetized, paralysed and mechanically ventilated before being randomized to receive intrapulmonary lipopolysaccharide (LPS) or no LPS. Pulse pressure (PP) was derived from the left carotid artery, whereas stroke volume (SV) was measured directly in the left ventricle. Values of SVV and PPV were calculated over three breaths. Balloon inflation of a catheter positioned in the inferior vena cava was used, for a maximum of 30s, to decrease preload while the SVV and PPV measurements were repeated. Values of C-Art were calculated as SV/PP. Intrapulmonary LPS increased C-Art and SV. Values of SVV and PPV increased in both LPS-treated and untreated rats during balloon inflation. There was a correlation between SVV and PPV in untreated rats before (r=0.55; P=0.005) and during (r=0.69; P<0.001) occlusion of the vena cava. There was no such correlation in LPS-treated rats either before (r=-0.08; P=0.70) or during (r=0.36; P=0.08) vena cava occlusion. In conclusion, under normovolaemic and hypovolaemic conditions, PPV does not reflect SVV during an increase in C-Art following LPS-induced pneumonia in mechanically ventilated rats. Our data caution against their interchangeability in human sepsis.
引用
收藏
页码:98 / 104
页数:7
相关论文
共 50 条
  • [31] Pulse pressure variation and stroke volume variation during different loading conditions in a paediatric animal model
    Renner, J.
    Cavus, E.
    Meybohm, P.
    Gruenewald, M.
    Steinfath, M.
    Scholz, J.
    Boening, A.
    Bein, B.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2008, 52 (03) : 374 - 380
  • [32] Use of Pulse Pressure Variation as Predictor of Fluid Responsiveness in Patients Ventilated With Low Tidal Volume: A Systematic Review and Meta-Analysis
    Alvarado Sanchez, Jorge Ivan
    Caicedo Ruiz, Juan Daniel
    Diaztagle Fernandez, Juan Jose
    Adolfo Ospina-Tascon, Gustavo
    Cruz Martinez, Luis Eduardo
    CLINICAL MEDICINE INSIGHTS-CIRCULATORY RESPIRATORY AND PULMONARY MEDICINE, 2020, 14
  • [33] Relationship of stroke volume variation, pulse pressure variation and global end-diastolic volume in patients undergoing brain surgery
    A Rieß
    S Wolf
    C Lumenta
    L Schürer
    P Friederich
    Critical Care, 14 (Suppl 1):
  • [34] l Pulse pressure variation and stroke volume variation to predict fluid responsiveness in patients undergoing carotid endarterectomy
    Kim, Kyung Mi
    Gwak, Mi Sook
    Choi, Soo Joo
    Kim, Myung Hee
    Park, Mi Hye
    Heo, Burn Young
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2013, 65 (03) : 237 - 243
  • [35] Automated stroke volume and pulse pressure variations predict fluid responsiveness in mechanically ventilated patients with obstructive jaundice
    Zhao, Feng
    Wang, Peng
    Pei, Shujun
    Mi, Weidong
    Fu, Qiang
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (11): : 20751 - 20759
  • [36] N-Acetylcysteine in Mechanically Ventilated Rats with Lipopolysaccharide-Induced Acute Respiratory Distress Syndrome: The Effect of Intravenous Dose on Oxidative Damage and Inflammation
    Kolomaznik, Maros
    Mikolka, Pavol
    Hanusrichterova, Juliana
    Kosutova, Petra
    Matasova, Katarina, Jr.
    Mokra, Daniela
    Calkovska, Andrea
    BIOMEDICINES, 2021, 9 (12)
  • [37] Reliability of pulse pressure and stroke volume variation in assessing fluid responsiveness in the operating room: a metanalysis and a metaregression
    Messina, Antonio
    Caporale, Mariagiovanna
    Calabro, Lorenzo
    Lionetti, Giulia
    Bono, Daniele
    Matronola, Guia Margherita
    Brunati, Andrea
    Frassanito, Luciano
    Morenghi, Emanuela
    Antonelli, Massimo
    Chew, Michelle S.
    Cecconi, Maurizio
    CRITICAL CARE, 2023, 27 (01)
  • [38] The Ability of Stroke Volume Variation Measured by a Noninvasive Cardiac Output Monitor to Predict Fluid Responsiveness in Mechanically Ventilated Children
    Ji Yeon Lee
    Ji Young Kim
    Chang Hyu Choi
    Hong Soon Kim
    Kyung Cheon Lee
    Hyun Jeong Kwak
    Pediatric Cardiology, 2014, 35 : 289 - 294
  • [39] The Ability of Stroke Volume Variation Measured by a Noninvasive Cardiac Output Monitor to Predict Fluid Responsiveness in Mechanically Ventilated Children
    Lee, Ji Yeon
    Kim, Ji Young
    Choi, Chang Hyu
    Kim, Hong Soon
    Lee, Kyung Cheon
    Kwak, Hyun Jeong
    PEDIATRIC CARDIOLOGY, 2014, 35 (02) : 289 - 294
  • [40] A systematic review of pulse pressure variation and stroke volume variation to predict fluid responsiveness during cardiac and thoracic surgery
    Piccioni, Federico
    Bernasconi, Filippo
    Tramontano, Giulia T. A.
    Langer, Martin
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (04) : 677 - 684