Novel creatine biosensors based on all solid-state contact ammonium-selective membrane electrodes

被引:4
作者
Altikatoglu, Melda [1 ]
Karakus, Emine [1 ]
Erci, Vildan [2 ]
Pekyardimci, Sule [3 ]
Isildak, Ibrahim [2 ]
机构
[1] Yildiz Tech Univ, Fac Arts & Sci, Dept Chem, TR-34210 Istanbul, Turkey
[2] Yildiz Tech Univ, Fac Chem & Met Engn, Dept Bioengn, TR-34210 Istanbul, Turkey
[3] Ankara Univ, Fac Sci, Dept Chem, TR-06100 Ankara, Turkey
关键词
Creatine; all solid-state biosensors; potentiometry; carboxylated PVC; palmitic acid; POTENTIOMETRIC BIOSENSORS; FLOW-INJECTION; PVC MEMBRANE; URIC-ACID; UREA; SYSTEM; PH;
D O I
10.3109/10731199.2012.696066
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Novel creatine bienzymatic potentiometric biosensors were prepared by immobilizing urease and creatinase on all solid-state contact PVC-containing palmitic acid and carboxylated PVC matrix membrane ammonium-selective electrodes without inner reference solution. Potentiometric characteristics of biosensors were examined in physiological model solutions at different creatine concentrations. The linear working range and long-term sensitivity of the biosensors were also determined. The creatine biosensors prepared by using the carboxylated PVC membrane electrodes showed more effective performance than those of the PVC containing palmitic acid membrane electrodes. Creatine assay in serum samples was successfully carried out by using the standard addition method.
引用
收藏
页码:131 / 136
页数:6
相关论文
共 44 条
[1]   Polypyrrole-based amperometric flow injection biosensor for urea [J].
Adeloju, SB ;
Shaw, SJ ;
Wallace, GG .
ANALYTICA CHIMICA ACTA, 1996, 323 (1-3) :107-113
[2]   BIOSENSORS BASED ON CONDUCTING FILLED POLYMER ALL-SOLID-STATE PVC MATRIX MEMBRANE ELECTRODES [J].
ALEGRET, S ;
MARTINEZFABREGAS, E .
BIOSENSORS, 1989, 4 (05) :287-297
[3]  
[Anonymous], 1886, physiol. Chem., DOI DOI 10.1515/BCHM1.1886.10.5.391
[4]   MINIATURIZED DISPOSABLE BIOSENSORS [J].
BILITEWSKI, U ;
CHEMNITIUS, GC ;
RUGER, P ;
SCHMID, RD .
SENSORS AND ACTUATORS B-CHEMICAL, 1992, 7 (1-3) :351-355
[5]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536
[6]   ION SELECTIVE ELECTRODES, POTENTIOMETRY, AND POTENTIOMETRIC TITRATIONS [J].
BUCK, RP .
ANALYTICAL CHEMISTRY, 1972, 44 (05) :R270-+
[7]   Analysis of creatine and creatinine in urine by capillary electrophoresis [J].
Burke, DG ;
MacLean, PG ;
Walker, RA ;
Dewar, PJ ;
Smith-Palmer, T .
JOURNAL OF CHROMATOGRAPHY B, 1999, 732 (02) :479-485
[8]   All Solid-State Potentiometric Biosensors for Creatinine Determination Based on pH and Ammonium Electrodes [J].
Chou, Nien-Hsuan ;
Chou, Jung-Chuan ;
Sun, Tai-Ping ;
Hsiung, Shen-Kan .
IEEE SENSORS JOURNAL, 2009, 9 (5-6) :665-672
[9]   High-throughput multi-analyte screening for renal disease using capillary electrophoresis [J].
Clark, EA ;
Fanguy, JC ;
Henry, CS .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 25 (5-6) :795-801
[10]   SPECTROPHOTOMETRIC SIMULTANEOUS DETERMINATION OF CREATININE AND CREATINE BY FLOW-INJECTION WITH REAGENT INJECTION [J].
DELCAMPO, G ;
IRASTORZA, A ;
CASADO, JA .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 352 (06) :557-561