Improved liquid-liquid extraction with inter-well volume replacement dilution workflow and its application to quantify BMS-927711 in rat dried blood spots by UHPLC-MS/MS

被引:8
作者
Zheng, Naiyu [1 ]
Zeng, Jianing [1 ]
Ji, Qin C. [1 ]
Angeles, Aida [1 ]
Buzescu, Adela [1 ]
Basdeo, Shenita [1 ]
Aubry, Anne-Francoise [1 ]
Trouba, Kevin [2 ]
Patrone, Laura M. [3 ]
Peng, Qianping [3 ]
Arnold, Mark E. [1 ]
机构
[1] Bristol Myers Squibb Co, Analyt & Bioanalyt Dev, Princeton, NJ 08543 USA
[2] Bristol Myers Squibb Co, Drug Safety Evaluat, Mt Vernon, IN 47620 USA
[3] Bristol Myers Squibb Co, Drug Safety Evaluat, New Brunswick, NJ 08903 USA
关键词
Dried blood spot (DBS); Sample dilution; Quantitation; Liquid-liquid extraction; UHPLC-MS/MS; ROBOTIC SAMPLE PREPARATION; DRUG DISCOVERY; LC-MS/MS; ASSAYS; DBS; BIOANALYSIS; VALIDATION; ANTAGONIST; MIGRAINE; PLASMA;
D O I
10.1016/j.jpba.2013.11.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An UHPLC-MS/MS method was developed and validated to quantify BMS-927711, a drug candidate to treat migraine, in rat dried blood spots (DBS). The DBS samples were extracted using an improved liquid-liquid extraction (LLE) strategy involving in the sonication of DBS punches in 20% MeOH aqueous solution containing the internal standard, [C-13(2), D-4]-BMS-927711, and then with a 100 mM NH4OAc buffer solution, followed by an automated LLE with EtOAc-hexane (70:30, v/v). The presence of 20% MeOH as an organic modifier in the elution solution significantly improved the analyte elution efficiency and assay performance. A novel inter-well volume replacement dilution workflow was introduced for DBS sample dilution before LLE step. This was a simple two-step process, firstly a small portion of the DBS blank solution was discarded, and then the same volume of a concentrated DBS sample solution was spiked into the leftover blank solution to achieve a desired dilution. Chromatographic separation was achieved on an Acuity UPLC (R) BEH C-18 column (2.1 mm x 50 mm, 1.7 mu m) and the analyte was detected by selected reaction monitoring (SRM) with positive electrospray ionization on an AB Sciex Triple Quad 5500 mass spectrometer. The standard curve was linear from 5.00 to 5000 ng/mL with assay precision <= 4.9% CV, and assay accuracy within +/- 3.1%Dev of the nominal values. Accurate sample dilution was achieved by using inter-well volume replacement with a precision of <= 4.2% CV and an accuracy of +/- 3.3% for dilution QC at 50,000 ng/mL with 100-fold dilution (n = 18). This robust UHPLC-MS/MS assay has been successfully applied to the non-clinical studies in rats. By using inter-well volume replacement workflow, accurate dilution was demonstrated using only one DBS blank sample for a typical dilution of <50-fold, and using only two blank DBS samples for a dilution of up to 625-fold. Moreover, this new workflow makes it easier to automate DBS sample dilution. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:240 / 250
页数:11
相关论文
共 2 条
  • [1] A UHPLC-MS/MS method coupled with liquid-liquid extraction for the quantitation of phenacetin, omeprazole, metoprolol, midazolam and their metabolites in rat plasma and its application to the study of four CYP450 activities
    Wang, Zhe
    Sun, Wei
    Lin, Zheng-Feng
    Sun, Rui
    Huang, Cheng-Ke
    Ye, Wei-Jian
    Dong, Yao-Yao
    Zhang, Xiao-Dan
    Chen, Rui-Jie
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 163 : 204 - 210
  • [2] Development of two step liquid-liquid extraction tandem UHPLC-MS/MS method for the simultaneous determination of Ginkgo flavonoids, terpene lactones and nimodipine in rat plasma: Application to the pharmacokinetic study of the combination of Ginkgo biloba dispersible tablets and Nimodipine tablets
    Xiao, Jie
    Wang, Tianyang
    Li, Pei
    Liu, Ran
    Li, Qing
    Bi, Kaishun
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1028 : 33 - 41