Development of a fast-switching dual (ESI/APCI) ionization source for liquid chromatography/mass spectrometry

被引:17
作者
Brecht, Dominik [1 ]
Uteschil, Florian [1 ]
Schmitz, Oliver J. [1 ]
机构
[1] Univ Duisburg Essen, Appl Analyt Chem, Univ Str 5, D-45141 Essen, Germany
关键词
ATMOSPHERIC-PRESSURE PHOTOIONIZATION; MASS-SPECTROMETRY; ION-SOURCE; LC-MS; ELECTROSPRAY;
D O I
10.1002/rcm.8845
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rationale High-throughput liquid chromatography/mass spectrometry (LC/MS) is an increasing topic in analytical chemistry. Especially the idle time of a mass spectrometer should be reduced for an efficient and cost-saving use. Therefore, a fast-switching dual ion source was developed, which uses the most important ionization techniques at atmospheric pressure, electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI), with one or more LC systems. Methods The performance of the developed ion source is shown by infusion experiments and chromatographic analyses of different standard substances. A high-throughput method is demonstrated by coupling two UHPLC systems to the dual ion source with a triple quadrupole mass spectrometer. Results No decrease in the ion abundance and a stable performance of the mass spectrometer are presented while using the dual ion source. Instrumental limits of detection are 30 ng L(-1)for testosterone using ESI and 1 mu g L(-1)for vitamin D(3)using APCI. A fast switching between two UHPLC systems and the dual ion source leads to a high sample throughput of 50 samples in 75 min with relative standard deviations for testosterone and vitamin D(3)of 1.5% and 3.8%, respectively. Conclusions This work presents the development of a dual ESI and APCI ion source operating simultaneously or in switched mode. The results show sensitive and reliable performance as well as the hyphenation to one or more HPLC systems.
引用
收藏
页数:9
相关论文
共 31 条
[1]   Thermogravimetry coupled to an atmospheric pressure photo ionization quadrupole mass spectrometry for the product control of pharmaceutical formulations and the analysis of plasticizers in polymers [J].
Brecht, Dominik ;
Uteschil, Florian ;
Schmitz, Oliver J. .
TALANTA, 2019, 198 :440-446
[2]  
Cappiello A, 2006, ADV LC MS INSTRUMENT, V72
[3]   ATMOSPHERIC-PRESSURE IONIZATION MASS-SPECTROMETRY - CORONA DISCHARGE ION-SOURCE FOR USE IN LIQUID CHROMATOGRAPH MASS SPECTROMETER-COMPUTER ANALYTICAL SYSTEM [J].
CARROLL, DI ;
DZIDIC, I ;
STILLWELL, RN ;
HAEGELE, KD ;
HORNING, EC .
ANALYTICAL CHEMISTRY, 1975, 47 (14) :2369-2373
[4]   Atmospheric-pressure laser ionization:: a novel ionization method for liquid chromatography/mass spectrometry [J].
Constapel, M ;
Schellenträger, M ;
Schmitz, OJ ;
Gäb, S ;
Brockmann, KJ ;
Giese, R ;
Benter, T .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (03) :326-336
[5]   Mass spectrometry in drug metabolism and pharmacokinetics: Current trends and future perspectives [J].
Cuyckens, Filip .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2019, 33 :90-95
[6]   MOLECULAR BEAMS OF MACROIONS [J].
DOLE, M ;
MACK, LL ;
HINES, RL .
JOURNAL OF CHEMICAL PHYSICS, 1968, 49 (05) :2240-&
[7]   Combined electrospray ionization-atmospheric pressure chemical ionization source for use in high-throughput LC-MS applications [J].
Gallagher, RT ;
Balogh, MP ;
Davey, P ;
Jackson, MR ;
Sinclair, I ;
Southern, LJ .
ANALYTICAL CHEMISTRY, 2003, 75 (04) :973-977
[8]  
Gross JH, 2011, MASS SPECTROMETRY PR, V100, P223
[9]  
Gross ML, 2003, ENCY MASS SPECTROMET
[10]  
Hitachi High Technologies Corporation, 2018, US Patent, Patent No. [0269049 A1.10.07, 0269049]