Long-term right ventricular implantable cardioverter-defibrillator lead performance in arrhythmogenic right ventricular cardiomyopathy

被引:8
作者
Herman, Adam R. M. [1 ]
Gardner, Martin [2 ]
Steinberg, Christian [1 ]
Yeung-Lai-Wah, John A. [1 ]
Healey, Jeff S. [3 ]
Leong-Sit, Peter [4 ]
Krahn, Andrew D. [1 ]
Chakrabarti, Santabhanu [1 ]
机构
[1] Univ British Columbia, Vancouver, BC, Canada
[2] QEII Hlth Sci Ctr, Halifax, NS, Canada
[3] Populat Hlth Res Inst, Hamilton, ON, Canada
[4] Western Univ, London, ON, Canada
关键词
Sensing; Implantation; Ventricular tachycardia; Lead performance; Cardiomyopathy; Genetics; OUTFLOW TRACT; FOLLOW-UP; TRICUSPID REGURGITATION; ATRIAL-FIBRILLATION; SINGLE-BLIND; SUDDEN-DEATH; THERAPY; COMPLICATIONS; DISEASE; VALIDATION;
D O I
10.1016/j.hrthm.2016.06.021
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a progressive disease characterized by replacement of normal myocardium by fibrofatty tissue. The right ventricular (RV) apex is the typical target for implantable cardioverter-defibrillator (ICD) lead placement, raising concerns for suboptimal lead performance in medium- to long-term follow-up. OBJECTIVE The purpose of this study was to determine whether placement of ICD leads at the RV apex was associated with performance deterioration of medium-term leads in ARVC patients compared to non-ARVC patients. METHODS In this multicenter, retrospective, case-control study, ICD lead performance measures of R-wave, impedance, and pacing thresholds were compared at baseline and between 1-year and 5-year postimplantation follow-up using mixed-effect models adjusted for age and sex. RESULTS One hundred one ARVC patients (49 women, age 50.6 +/- 14.5 years) were compared to 56 control patients (37 women, age 48.2 +/- 14.2 years). The mean difference in R wave between years 1 and 2 was -0.85 mV (P = .16) compared to a mean difference at years 5 and 6 of -1.85 mV (P = .02). There was no difference in impedance or pacing threshold or in lead lifetime between the 2 groups over 6-year follow-up (5.91 +/- 3.89 years vs 5.48 +/- 3.70 years, P = .239). CONCLUSION In ARVC patients with ICD leads implanted in the RV apex, ventricular sensing deteriorates significantly during medium term follow-up. Septal RV lead placement should be explored as the first choice at implantation.
引用
收藏
页码:1964 / 1970
页数:7
相关论文
共 50 条
  • [1] Long-Term Performance of Right Ventricular Implantable Cardioverter-Defibrillator Leads in Arrhythmogenic Right Ventricular Cardiomyopathy and Hypertrophic Cardiomyopathy
    Sagawa, Yuichiro
    Nagata, Yasutoshi
    Yamaguchi, Tetsuo
    Mitsui, Kentaro
    Nagamine, Tatsuhiro
    Yamaguchi, Junji
    Hijikata, Sadahiro
    Watanabe, Keita
    Masuda, Ryo
    Miyazaki, Ryoichi
    Kaneko, Masakazu
    Miwa, Naoyuki
    Sekigawa, Masahiro
    Hara, Nobuhiro
    Nozato, Toshihiro
    Ashikaga, Takashi
    Goya, Masahiko
    Sasano, Tetsuo
    Hirao, Kenzo
    INTERNATIONAL HEART JOURNAL, 2020, 61 (01) : 39 - 45
  • [2] Complications of implantable cardioverter-defibrillator treatment in arrhythmogenic right ventricular cardiomyopathy
    Christensen, Alex Horby
    Platonov, Pyotr G.
    Svensson, Anneli
    Jensen, Henrik K.
    Rootwelt-Norberg, Christine
    Dahlberg, Pia
    Madsen, Trine
    Frederiksen, Tanja Charlotte
    Helio, Tiina
    Haugaa, Kristina H.
    Bundgaard, Henning
    Svendsen, Jesper H.
    EUROPACE, 2022, 24 (02): : 306 - 312
  • [3] Implantable Cardioverter-Defibrillator Therapy in Arrhythmogenic Right Ventricular Cardiomyopathy: long-term single centre experience
    Blandino, Alessandro
    Gallo, Cristina
    Anselmino, Matteo
    Giustetto, Carla
    Morello, Mara
    Toso, Elisabetta
    Miceli, Salvatore
    Garberoglio, Lucia
    Gaita, Fiorenzo
    CIRCULATION, 2010, 122 (21)
  • [4] Long-term follow-up of arrhythmogenic right ventricular cardiomyopathy patients with an implantable cardioverter-defibrillator for prevention of sudden cardiac death
    Yin, Kang
    Ding, Ligang
    Li, Yuqiu
    Hua, Wei
    CLINICAL CARDIOLOGY, 2017, 40 (04) : 216 - 221
  • [5] Long-term prognosis of patients with arrhythmogenic right ventricular cardiomyopathy and implantable defibrillator
    Ruiz-Salas, Amalio
    Cabrera-Bueno, Fernando
    Manuel Garcia-Pinilla, Jose
    Barrera-Cordero, Alberto
    Pena-Hernandez, Jose
    Fernandez-Pastor, Julia
    Medina-Palomo, Carmen
    Alzueta-Rodriguez, Javier
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 174 (03) : 794 - 796
  • [6] Very Long-Term Follow-up in Patients With Arrhythmogenic Right Ventricular Cardiomyopathy and an Implantable Cardioverter/Defibrillator
    Paul, Matthias
    Koebe, Julia
    Loeher, Andreas
    Scheld, Hans H.
    Breithardt, Guenter
    Wichter, Thomas
    Eckardt, Lars
    CIRCULATION, 2010, 122 (21)
  • [7] Outcome of cardioverter-defibrillator implant in patients with arrhythmogenic right ventricular cardiomyopathy
    Boriani, Giuseppe
    Artale, Paolo
    Biffi, Mauro
    Martignani, Cristian
    Frabetti, Lorenzo
    Valzania, Cinzia
    Diemberger, Igor
    Ziacchi, Matteo
    Bertini, Matteo
    Rapezzi, Claudio
    Parlapiano, Mario
    Branzi, Angelo
    HEART AND VESSELS, 2007, 22 (03) : 184 - 192
  • [8] Subcutaneous Implantable Cardioverter-Defibrillator in Patients With Arrhythmogenic Right Ventricular Cardiomyopathy/Dysplasia: A Transatlantic Experience
    Orgeron, Gabriela M.
    Bhonsale, Aditya
    Migliore, Federico
    James, Cynthia A.
    Tichnell, Crystal
    Murray, Brittney
    Bertaglia, Emanuele
    Cadrin-Tourigny, Julia
    De Franceschi, Pietro
    Crosson, Jane
    Tandri, Harikrishna
    Corrado, Domenico
    Calkins, Hugh
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2018, 7 (21):
  • [9] Incidence and Predictors of Implantable Cardioverter-Defibrillator Therapy in Patients With Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy Undergoing Implantable Cardioverter-Defibrillator Implantation for Primary Prevention
    Bhonsale, Aditya
    James, Cynthia A.
    Tichnell, Crystal
    Murray, Brittney
    Gagarin, Dmitri
    Philips, Binu
    Dalal, Darshan
    Tedford, Ryan
    Russell, Stuart D.
    Abraham, Theodore
    Tandri, Harikrishna
    Judge, Daniel P.
    Calkins, Hugh
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (14) : 1485 - 1496
  • [10] Implantable Cardioverter defibrillator in arrhythmogenic right ventricular cardiomyopathies
    Fontaine, G
    Prost-Squarcioni, C
    CIRCULATION, 2004, 109 (12) : 1445 - 1447