Axial compression-bending interaction behavior of severely damaged RC columns rapid repaired and strengthened using hybrid FRP composites

被引:34
作者
Chellapandian, M. [1 ]
Prakash, S. Suriya [1 ]
Sharma, Akanshu [2 ]
机构
[1] Indian Inst Technol Hyderabad, Struct Engn Div, Hyderabad, Telangana, India
[2] Univ Stuttgart, IWB, Stuttgart, Germany
关键词
Hybrid FRP technique; P-M interaction; NSM; Rapid repair; Severe damage; REINFORCED-CONCRETE COLUMNS; SEISMIC BEHAVIOR; BEAMS; CONFINEMENT; FLEXURE;
D O I
10.1016/j.conbuildmat.2018.11.090
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper investigates the axial compression and bending interaction behavior of reinforced concrete (RC) columns repaired and strengthened with different FRP (Fiber Reinforced Polymer) techniques after severe damage. The columns were initially damaged under different axial compression to bending load ratios. The loads were applied at different eccentricity (e) to depth (h) ratios to have (i) pure compression (e/h = 0), (ii) eccentric compression (e/h = 0.63) and (iii) pure flexure (e/h = infinity). After initial damage, the specimens underwent severe concrete core degradation with the main steel reinforcement reaching its yield strain. Later, the specimens were repaired using high strength cement grout (HSCG) and further strengthened using (i) near surface mounting (NSM) of carbon FRP (CFRP) laminates and (ii) hybrid FRP technique with a combination of NSM laminates and external bonded (EB) fabrics. After that, the columns were loaded again until failure. An axial compression (P) - bending moment (M) interaction diagram was developed experimentally for the severely damaged columns. Also, the interaction curves were developed analytically using strain compatibility procedure with the modified constitutive models. Experimental results reveal that the specimens repaired and strengthened using hybrid FRP technique can effectively restore the original capacity under different eccentric load levels. The analytical predictions showed a close match when compared to the experimental observations. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:390 / 404
页数:15
相关论文
共 55 条
  • [1] AAHSTO, 2017, LFRD BRIDG DES SPEC
  • [2] Experimental and numerical study of the behaviour of heat-damaged RC circular columns confined with CFRP fabric
    Al-Kamaki, Yaman S. S.
    Al-Mahaidi, Riadh
    Bennetts, Ian
    [J]. COMPOSITE STRUCTURES, 2015, 133 : 679 - 690
  • [3] Active Confinement of Reinforced Concrete Bridge Columns Using Shape Memory Alloys
    Andrawes, Bassem
    Shin, Moochul
    Wierschem, Nicholas
    [J]. JOURNAL OF BRIDGE ENGINEERING, 2010, 15 (01) : 81 - 89
  • [4] [Anonymous], 2017, 4402R17 ACI, P45
  • [5] [Anonymous], 2014, 1893 IS
  • [6] [Anonymous], D6864M14 ASTM
  • [7] ASTM, 2017, D3039M17 ASTM
  • [8] Near surface mounted CFRP strips for the flexural strengthening of RC columns: Experimental and numerical research
    Barros, Joaquim A. O.
    Varma, Rajendra K.
    Sena-Cruz, Jose M.
    Azevedo, Alvaro F. M.
    [J]. ENGINEERING STRUCTURES, 2008, 30 (12) : 3412 - 3425
  • [9] Bournas DA, 2009, ACI STRUCT J, V106, P495
  • [10] Rapid repair of severely damaged reinforced concrete columns under combined axial compression and flexure: An experimental study
    Chellapandian, M.
    Prakash, S. Suriya
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2018, 173 : 368 - 380