Cervical Spine Movement During Awake Orotracheal Intubation With Fiberoptic Scope and McGrath Videolaryngoscope in Patients Undergoing Surgery for Cervical Spine Instability: A Randomized Control Trial

被引:18
作者
Dutta, Kaustuv [1 ]
Sriganesh, Kamath [1 ]
Chakrabarti, Dhritiman [1 ]
Pruthi, Nupur [2 ]
Reddy, Madhusudan [1 ]
机构
[1] Natl Inst Mental Hlth & Neurosci NIMHANS, Dept Neuroanaesthesia & Neurocrit Care, Bengaluru, Karnataka, India
[2] Natl Inst Mental Hlth & Neurosci NIMHANS, Dept Neurosurg, Bengaluru, Karnataka, India
关键词
McGrath videolaryngoscope; fiberoptic scope; cervical spine instability; intubation; cervical spine movement; neurological deficit; TRACHEAL INTUBATION; VIDEO LARYNGOSCOPE; AIRWAY MANAGEMENT; SERIES; 5; ENDOTRACHEAL INTUBATION; MACINTOSH LARYNGOSCOPE; MCCOY LARYNGOSCOPE; MOTION;
D O I
10.1097/ANA.0000000000000595
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Cervical spine movement during intubation with direct laryngoscopy can predispose to new-onset neurological deficits in patients with cervical spine instability. While fiberoptic-guided intubation (FGI) is mostly preferred in such patients, this is not always possible. Videolaryngoscopy results in less cervical spine movement than direct laryngoscopy and may be an alternative to FGI in patients with cervical spine instability. The objective of this study was to compare cervical spine movement during awake FGI with those during awake McGrath videolaryngoscope-guided intubation (VGI) in patients undergoing surgery for cervical spine instability. Methods: Forty-six adult patients with upper cervical spine instability scheduled for stabilization surgery were randomized to awake FGI or awake VGI. Cervical spine movement during intubation was assessed by changes in lateral fluoroscopic-measured angles (alpha and beta at C1/C2 and C3 levels, respectively) at 3 time points: T1, preintubation; T2, during intubation; T3, postintubation. Motor power was assessed before and after intubation. Results: Patient demographics and airway characteristics were similar between the 2 groups. Cervical spine motion (in degrees) during intubation was significantly greater with VGI than FGI at C1/C2 (T3-T1, -8.02 +/- 8.11 vs. -1.47 +/- 3.31;P<0.001) but not at C3 (T3-T1, -2.17 +/- 5.16 vs. -1.85 +/- 3.29;P=0.960). No patient developed new-onset motor deficits following intubation in either group. Conclusions: Compared with FGI, VGI results in a greater degree of cervical spine movement at C1/C2 but not at C3.
引用
收藏
页码:249 / 255
页数:7
相关论文
共 33 条
  • [21] A comparison of Disposcope endoscope and Fiberoptic bronchoscope during awake orotracheal intubation in obese patients with anticipated difficult airway: a prospective, randomized and controlled clinical trial
    Liu, Zhuo
    Zhao, Li
    Jia, Qianqian
    Liang, Shujuan
    Yang, Xiaochun
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (09): : 9654 - 9661
  • [22] A comparative evaluation of Airtraq and Hansraj Video laryngoscopes in patients undergoing tracheal intubation with cervical spine immobilization - A randomized prospective study
    Varshney, Poojangi
    Ahmed, Syed M.
    Siddiqui, Obaid A.
    Abu Nadeem
    Ajmal, P. M.
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2021, 37 (03) : 336 - 341
  • [23] Effects of External Laryngeal Manipulation on Cervical Spine Motion during Videolaryngoscopic Intubation under Manual In-Line Stabilization: A Randomized Crossover Trial
    Kim, Yoon Jung
    Hur, Chahnmee
    Yoon, Hyun-Kyu
    Lee, Hyung-Chul
    Park, Hee-Pyoung
    Oh, Hyongmin
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (13)
  • [24] Shikani Optical Stylet versus Macintosh Laryngoscope for Intubation in Patients Undergoing Surgery for Cervical Spondylosis: A Randomized Controlled Trial
    Xu, Mao
    Li, Xiao-Xi
    Guo, Xiang-Yang
    Wang, Jun
    CHINESE MEDICAL JOURNAL, 2017, 130 (03) : 297 - 302
  • [25] Direct versus indirect epiglottis elevation in cervical spine movement during videolaryngoscopic intubation under manual in-line stabilization: a randomized controlled trial
    Seungeun Choi
    Dong Ju Lee
    Kyung Won Shin
    Yoon Jung Kim
    Hee-Pyoung Park
    Hyongmin Oh
    BMC Anesthesiology, 23
  • [26] A comparative study of the C-MAC D-blade videolaryngoscope and McCoy laryngoscope for oro-tracheal intubation with manual in-line stabilization of neck in patients undergoing cervical spine surgery
    Kumari, Astha
    Choudhuri, Pratiti
    Agrawal, Nidhi
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2023, 39 (03) : 435 - 443
  • [27] Cervical spine motion during videolaryngoscopic intubation using a Macintosh-style blade with and without the anterior piece of a cervical collar: a randomized controlled trial
    Jo, Woo-Young
    Choi, Jae-Hyun
    Kim, Jay
    Shin, Kyung
    Choi, Seungeun
    Park, Hee-Pyoung
    Oh, Hyongmin
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2025, 72 (01): : 142 - 151
  • [28] Shikani Optical Stylet versus Macintosh Laryngoscope for Intubation in Patients Undergoing Surgery for Cervical Spondylosis: A Randomized Controlled Trial
    Xu Mao
    Li Xiao-Xi
    Guo Xiang-Yang
    Wang Jun
    中华医学杂志英文版, 2017, 130 (03) : 297 - 302
  • [29] Comparison of the paediatric blade of the Pentax-AWS and Ovassapian airway in fibreoptic tracheal intubation in patients with limited mouth opening and cervical spine immobilization by a semi-rigid neck collar: a randomized controlled trial
    Kim, D. H.
    Yoo, J. Y.
    Ha, S. Y.
    Chae, Y. J.
    BRITISH JOURNAL OF ANAESTHESIA, 2017, 119 (05) : 993 - 999
  • [30] Comparison of C-MAC D-Blade with macintosh laryngoscope for endotracheal intubation in patients with cervical spine immobilization: A randomized controlled trial
    Agrawal, Nidhi
    Saini, Suman
    Gupta, Anju
    Kabi, Ankita
    Girdhar, K. K.
    TRENDS IN ANAESTHESIA AND CRITICAL CARE, 2021, 37 : 35 - 41