APSIC guidelines for disinfection and sterilization of instruments in health care facilities

被引:84
作者
Ling, Moi Lin [1 ]
Ching, Patricia [2 ]
Widitaputra, Ammar [3 ]
Stewart, Alison [4 ]
Sirijindadirat, Nanthipha [5 ]
Le Thi Anh Thu [6 ]
机构
[1] Singapore Gen Hosp, Infect Prevent & Control, Singapore 169608, Singapore
[2] HKICNA, Hong Kong, Hong Kong, Peoples R China
[3] Himpunan Sterilasi Sentral Indonesia HISSI, Jakarta, Indonesia
[4] NZSSA, Waikiwi, New Zealand
[5] Cent Sterilizing Serv Assoc, Bangkok, Thailand
[6] Ho Chi Minh City Infect Control Soc HICS, Ho Chi Minh City, Vietnam
来源
ANTIMICROBIAL RESISTANCE AND INFECTION CONTROL | 2018年 / 7卷
关键词
Cleaning; Disinfection; Sterilization; Endoscopes; Reprocessing; CARBAPENEM-RESISTANT ENTEROBACTERIACEAE; GASTROINTESTINAL ENDOSCOPES; OUTBREAK; DUODENOSCOPES; TRANSMISSION; INFECTIONS; SUPERBUGS; RISK;
D O I
10.1186/s13756-018-0308-2
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: The Asia Pacific Society of Infection Control launched its revised Guidelines for Disinfection and Sterilization of Instruments in Health Care Facilities in February 2017. This document describes the guidelines and recommendations for the reprocessing of instruments in healthcare setting. It aims to highlight practical recommendations in a concise format designed to assist healthcare facilities at Asia Pacific region in achieving high standards in sterilization and disinfection. Method: The guidelines were revised by an appointed workgroup comprising experts in the Asia Pacific region, following reviews of previously published guidelines and recommendations relevant to each section. Results: It recommends the centralization of reprocessing, training of all staff with annual competency assessment, verification of cleaning, continual monitoring of reprocessing procedures to ensure their quality and a corporate strategy for dealing with single-use and single-patient use medical equipment/devices. Detailed recommendations are also given with respect to reprocessing of endoscopes. Close working with the Infection Prevention & Control department is also recommended where decisions related to reprocessing medical equipment/devices are to be made. Conclusions: Sterilization facilities should aim for excellence in practices as this is part of patient safety. The guidelines that come with a checklist help service providers identify gaps for improvement to reach this goal.
引用
收藏
页数:11
相关论文
共 52 条
[1]  
American Society for Healthcare Central Service Professionals of the American Hospital Association, 2006, TRAIN MAN HLTH CAR C
[2]  
[Anonymous], 2014, REC PRACT STER PER S, P575
[3]  
[Anonymous], 2008, Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008
[4]  
[Anonymous], 2011, INF PREV CONTR GUID
[5]  
[Anonymous], 2011, 176642004 EN ISO
[6]  
[Anonymous], 2014, DESIGN CONSTRUCTION
[7]  
AORN Recommended Practices for Cleaning and Care of Surgical Instruments and Powered Equipment, 2010, AORN REC PRACT SEL U, P421
[8]  
Association for the Advancement of Medical Instrumentation, 2014, ST792010A42013 ANSIA
[9]  
Association for the Advancement of Medical Instrumentation (AMMI), ST5820131154 ANSIAAM
[10]  
Association for the Advancement of Medical Instrumentation (AMMI), ST792010A220111230 A