Transapical aortic valve implantation using a new self-expandable bioprosthesis (ACURATE TA™): 6-month outcomes†

被引:55
|
作者
Kempfert, Joerg [1 ]
Treede, Hendrik [2 ]
Rastan, Ardawan J. [3 ]
Schoenburg, Markus [1 ]
Thielmann, Matthias [4 ]
Sorg, Stefan [5 ]
Mohr, Friedrich-W. [3 ]
Walther, Thomas [1 ]
机构
[1] Kerckhoff Clin Bad Nauheim, Dept Cardiac Surg, D-61231 Bad Nauheim, Germany
[2] Univ Hamburg, Dept Cardiac Surg, Heartctr, Hamburg, Germany
[3] Univ Leipzig, Dept Cardiac Surg, Heartctr, Leipzig, Germany
[4] Univ Duisburg Essen, West German Heart Ctr Essen, Dept Cardiac Surg, Essen, Germany
[5] Univ Freiburg, Dept Cardiac Surg, Clin Cardiac Surg, D-79106 Freiburg, Germany
关键词
Aortic valve implantation; Minimally invasive; Transapical; HIGH-RISK PATIENTS; OUTCOME SOURCE REGISTRY; EDWARDS SAPIEN VALVE; EUROPEAN REGISTRY; TRANSCATHETER; REPLACEMENT; EXPERIENCE; STENOSIS; PROSTHESIS; PREDICTORS;
D O I
10.1093/ejcts/ezs139
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The ACURATE TA((TM)) Aortic Bioprosthesis and Delivery System (Symetis S.A., Ecublens, Switzerland) is a new transcatheter aortic valve designed for transapical implantation. The six-month results from the completed first-in-man study are reported. The Symetis ACURATE TA((TM)) is composed of a porcine biological tissue valve attached to a self-expandable nitinol stent. It allows for anatomical orientation and facilitates intuitive implantation providing tactile feedback. Since November 2009, a total of 40 high-risk elderly patients have been treated. The mean age of enrolled patients was 83.2 +/- 4.0; 60.0% were female, with a mean logistic EuroSCORE of 21.2 +/- 10.8% and a mean Society of Thoracic Surgeons (STS) score of 9.0 +/- 4.7%. All implants were delivered successfully in the intra-annular and subcoronary position. One patient was converted to conventional surgery due to coronary impingement (after valve-in-valve implantation). One additional patient received valve-in-valve treatment (SAPIEN THV TA((TM))). Five patients expired within 30 days and two additional patients expired during the 6-month follow-up due to non-valve-related causes resulting in a mid-term survival rate of 82.5%. Two patients suffered a stroke and another three required new onset pacemaker implantation. The mean aortic gradient significantly improved and remained stable throughout the follow-up (baseline: 51.9 +/- 14.3 mmHg, 30 days: 12.3 +/- 5.1 mmHg, 6 months: 11.9 +/- 5.8 mmHg). At the 6-month follow-up, 96.7% of patients demonstrated either none/trace or mild (1+/4) paravalvular leakage only. According to the Valve Academic Research Council the device's success rate was 92.5%, with a 30-day safety profile of 25%. At the 6-month follow-up, the ACURATE TA((TM)) device showed stable valve function with low rates of paravalvular leakages. The cohort of high-risk patients demonstrated good clinical outcomes and 6-month survival.
引用
收藏
页码:52 / 57
页数:6
相关论文
共 50 条
  • [21] Incidence, Predictors, and Outcome of Conduction Disorders After Transcatheter Self-Expandable Aortic Valve Implantation
    Fraccaro, Chiara
    Buja, Gianfranco
    Tarantini, Giuseppe
    Gasparetto, Valeria
    Leoni, Loira
    Razzolini, Renato
    Corrado, Domenico
    Bonato, Raffaele
    Basso, Cristina
    Thiene, Gaetano
    Gerosa, Gino
    Isabella, Giambattista
    Iliceto, Sabin
    Napodano, Massimo
    AMERICAN JOURNAL OF CARDIOLOGY, 2011, 107 (05) : 747 - 754
  • [22] Twelve-month outcomes of transapical transcatheter aortic valve implantation in patients with severe aortic valve stenosis
    Wiewiorka, Lukasz
    Sobczynski, Robert
    Trebacz, Jaroslaw
    Sadowski, Jerzy
    Dudek, Dariusz
    Stapor, Maciej
    Konstanty-Kalandyk, Janusz
    Musial, Robert
    Gackowski, Andrzej
    Malinowski, Krzystof
    Kleczynski, Pawel
    Zmudka, Krzysztof
    Kapelak, Boguslaw
    Legutko, Jacek
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2021, 17 (01): : 68 - 74
  • [23] Transcathether aortic valve implantation with the new repositionable self-expandable Evolut R versus CoreValve system: A case-matched comparison
    Giannini, Cristina
    De Carlo, Marco
    Tamburino, Corrado
    Ettori, Federica
    Latib, Azeem M.
    Bedogni, Francesco
    Bruschi, Giuseppe
    Presbitero, Patrizia
    Poli, Arnaldo
    Fabbiocchi, Franco
    Violini, Roberto
    Trani, Carlo
    Giudice, Pietro
    Barbanti, Marco
    Adamo, Marianna
    Colombo, Paola
    Benincasa, Susanna
    Agnifili, Mauro
    Petronio, A. Sonia
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 243 : 126 - 131
  • [24] Occurrence and prognostic impact of systemic inflammatory response syndrome in transfemoral and transapical aortic valve implantation with balloon- and self-expandable valves
    Schwietz, Thomas
    Behjati, Sohil
    Gafoor, Sameer
    Seeger, Florian
    Doss, Mirko
    Sievert, Horst
    Zeiher, Andreas M.
    Fichtlscherer, Stephan
    Lehmann, Ralf
    EUROINTERVENTION, 2015, 10 (12) : 1468 - 1473
  • [25] Transcatheter aortic valve implantation using the ACURATE TA and ACURATE neo valves: a four-year single-centre experience
    Hammy, Karsten
    Reents, Wilko
    Zacher, Michael
    Kerber, Sebastian
    Diegeler, Anno
    Schleifer, Bernhard
    Barth, Sebastian
    EUROINTERVENTION, 2017, 13 (01) : 53 - 59
  • [26] Transapical implantation of a self-expanding aortic valve bioprosthesis - animal feasibility study
    Kappetein, Arie-Pieter
    Piazza, Nicolo
    Laborde, Jean-Claude
    de Jaegere, Peter P.
    Serruys, Patrick W.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2009, 36 (05) : 813 - 817
  • [27] Coronary Angioplasty After Self-Expandable Transcatheter Aortic Valve Implantation
    Greenberg, Gabriel
    Kornowski, Ran
    JOURNAL OF INVASIVE CARDIOLOGY, 2013, 25 (07) : 361 - 363
  • [28] Aortic Angulation Does Not Impact Outcomes in Self-Expandable or Balloon-Expandable Transcatheter Aortic Valve Replacement
    Elmously, Adham
    Gray, Katherine D.
    Truong, Quynh A.
    Burshtein, Aaron
    Wong, S. Chiu
    de Biasi, Andreas R.
    Worku, Berhane
    Salemi, Arash
    CARDIOLOGY, 2018, 140 (02) : 96 - 102
  • [29] Percutaneous implantation of self-expandable aortic valve in high risk patients with severe aortic stenosis: The first experiences in Serbia
    Nedeljkovic, Milan A.
    Beleslin, Branko
    Tesic, Milorad
    Vukcevic, Vladan
    Stankovic, Goran
    Stojkovic, Sinisa
    Orlic, Dejan
    Bilbija, Ilija
    Matkovic, Milos
    Simic, Tijana
    Menkovic, Nemanja
    Mrdovic, Igor
    Ussia, Gian Paolo
    Perisic, Zoran
    Babic, Momcilo
    VOJNOSANITETSKI PREGLED, 2016, 73 (02) : 192 - 197
  • [30] Self-Expandable Transcatheter Aortic Valve Implantation Outcomes: Findings From the Western Region of Saudi Arabia
    Albugami, Saad
    Al-Husayni, Faisal
    Alfouti, Mawaddah
    Algahtani, Mohammed
    Alansari, Wasna
    Hanawi, Maha
    Albokhari, Ammar
    Alkashkari, Wail
    Mufti, Hani N.
    Krimly, Ahmed
    Alameen, Wail
    Albawardy, Rasha
    Alsaiedi, Abdullah
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (09)