Transapical aortic valve implantation using a new self-expandable bioprosthesis (ACURATE TA™): 6-month outcomes†

被引:55
作者
Kempfert, Joerg [1 ]
Treede, Hendrik [2 ]
Rastan, Ardawan J. [3 ]
Schoenburg, Markus [1 ]
Thielmann, Matthias [4 ]
Sorg, Stefan [5 ]
Mohr, Friedrich-W. [3 ]
Walther, Thomas [1 ]
机构
[1] Kerckhoff Clin Bad Nauheim, Dept Cardiac Surg, D-61231 Bad Nauheim, Germany
[2] Univ Hamburg, Dept Cardiac Surg, Heartctr, Hamburg, Germany
[3] Univ Leipzig, Dept Cardiac Surg, Heartctr, Leipzig, Germany
[4] Univ Duisburg Essen, West German Heart Ctr Essen, Dept Cardiac Surg, Essen, Germany
[5] Univ Freiburg, Dept Cardiac Surg, Clin Cardiac Surg, D-79106 Freiburg, Germany
关键词
Aortic valve implantation; Minimally invasive; Transapical; HIGH-RISK PATIENTS; OUTCOME SOURCE REGISTRY; EDWARDS SAPIEN VALVE; EUROPEAN REGISTRY; TRANSCATHETER; REPLACEMENT; EXPERIENCE; STENOSIS; PROSTHESIS; PREDICTORS;
D O I
10.1093/ejcts/ezs139
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The ACURATE TA((TM)) Aortic Bioprosthesis and Delivery System (Symetis S.A., Ecublens, Switzerland) is a new transcatheter aortic valve designed for transapical implantation. The six-month results from the completed first-in-man study are reported. The Symetis ACURATE TA((TM)) is composed of a porcine biological tissue valve attached to a self-expandable nitinol stent. It allows for anatomical orientation and facilitates intuitive implantation providing tactile feedback. Since November 2009, a total of 40 high-risk elderly patients have been treated. The mean age of enrolled patients was 83.2 +/- 4.0; 60.0% were female, with a mean logistic EuroSCORE of 21.2 +/- 10.8% and a mean Society of Thoracic Surgeons (STS) score of 9.0 +/- 4.7%. All implants were delivered successfully in the intra-annular and subcoronary position. One patient was converted to conventional surgery due to coronary impingement (after valve-in-valve implantation). One additional patient received valve-in-valve treatment (SAPIEN THV TA((TM))). Five patients expired within 30 days and two additional patients expired during the 6-month follow-up due to non-valve-related causes resulting in a mid-term survival rate of 82.5%. Two patients suffered a stroke and another three required new onset pacemaker implantation. The mean aortic gradient significantly improved and remained stable throughout the follow-up (baseline: 51.9 +/- 14.3 mmHg, 30 days: 12.3 +/- 5.1 mmHg, 6 months: 11.9 +/- 5.8 mmHg). At the 6-month follow-up, 96.7% of patients demonstrated either none/trace or mild (1+/4) paravalvular leakage only. According to the Valve Academic Research Council the device's success rate was 92.5%, with a 30-day safety profile of 25%. At the 6-month follow-up, the ACURATE TA((TM)) device showed stable valve function with low rates of paravalvular leakages. The cohort of high-risk patients demonstrated good clinical outcomes and 6-month survival.
引用
收藏
页码:52 / 57
页数:6
相关论文
共 19 条
[11]   Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery. [J].
Leon, Martin B. ;
Smith, Craig R. ;
Mack, Michael ;
Miller, D. Craig ;
Moses, Jeffrey W. ;
Svensson, Lars G. ;
Tuzcu, E. Murat ;
Webb, John G. ;
Fontana, Gregory P. ;
Makkar, Raj R. ;
Brown, David L. ;
Block, Peter C. ;
Guyton, Robert A. ;
Pichard, Augusto D. ;
Bavaria, Joseph E. ;
Herrmann, Howard C. ;
Douglas, Pamela S. ;
Petersen, John L. ;
Akin, Jodi J. ;
Anderson, William N. ;
Wang, Duolao ;
Pocock, Stuart .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (17) :1597-1607
[12]   Effect of Experience on Results of Transcatheter Aortic Valve Implantation Using a Medtronic Core Valve System [J].
Nuis, Rutger-Jan ;
van Mieghem, Nicolas M. ;
van der Boon, Robert M. ;
van Geuns, Robert-Jan ;
Schultz, Carl J. ;
Oei, Frans B. ;
Galema, Tjebbe W. ;
Raap, Goris Bol ;
Koudstaal, Peter J. ;
Geleijnse, Marcel L. ;
Kappetein, Arie Pieter ;
Serruys, Patrick W. ;
de Jaegere, Peter P. .
AMERICAN JOURNAL OF CARDIOLOGY, 2011, 107 (12) :1824-1829
[13]  
Piazza Nicolo, 2008, EuroIntervention, V4, P242, DOI 10.4244/EIJV4I2A43
[14]   Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients [J].
Smith, Craig R. ;
Leon, Martin B. ;
Mack, Michael J. ;
Miller, Craig ;
Moses, Jeffrey W. ;
Svensson, Lars G. ;
Tuzcu, E. Murat ;
Webb, John G. ;
Fontana, Gregory P. ;
Makkar, Raj R. ;
Williams, Mathew ;
Dewey, Todd ;
Kapadia, Samir ;
Babaliaros, Vasilis ;
Thourani, Vinod H. ;
Corso, Paul ;
Pichard, Augusto D. ;
Bavaria, Joseph E. ;
Herrmann, Howard C. ;
Akin, Jodi J. ;
Anderson, William N. ;
Wang, Duolao ;
Pocock, Stuart J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2011, 364 (23) :2187-2198
[15]   One-Year Outcomes of Cohort 1 in the Edwards SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry The European Registry of Transcatheter Aortic Valve Implantation Using the Edwards SAPIEN Valve [J].
Thomas, Martyn ;
Schymik, Gerhard ;
Walther, Thomas ;
Himbert, Dominique ;
Lefevre, Thierry ;
Treede, Hendrik ;
Eggebrecht, Holger ;
Rubino, Paolo ;
Colombo, Antonio ;
Lange, Ruediger ;
Schwarz, Rebecca R. ;
Wendler, Olaf .
CIRCULATION, 2011, 124 (04) :425-433
[16]   Thirty-Day Results of the SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry A European Registry of Transcatheter Aortic Valve Implantation Using the Edwards SAPIEN Valve [J].
Thomas, Martyn ;
Schymik, Gerhard ;
Walther, Thomas ;
Himbert, Dominique ;
Lefevre, Thierry ;
Treede, Hendrik ;
Eggebrecht, Holger ;
Rubino, Paolo ;
Michev, Iassen ;
Lange, Ruediger ;
Anderson, William N. ;
Wendler, Olaf .
CIRCULATION, 2010, 122 (01) :62-U130
[17]   Transapical minimally invasive aortic valve implantation - Multicenter experience [J].
Walther, Thomas ;
Simon, Paul ;
Dewey, Todd ;
Wimmer-Greinecker, Gerhard ;
Falk, Volkmar ;
Kasimir, Marie T. ;
Doss, Mirko ;
Borger, Michael A. ;
Schuler, Gerhard ;
Glogar, Dietmar ;
Fehske, Wolfgang ;
Wolner, Ernst ;
Mohr, Friedrich W. ;
Mack, Michael .
CIRCULATION, 2007, 116 (11) :I240-I245
[18]   Percutaneous transarterial aortic valve replacement in selected high-risk patients with aortic stenosis [J].
Webb, John G. ;
Pasupati, Sanjeevan ;
Humphries, Karin ;
Thompson, Christopher ;
Altwegg, Lukas ;
Moss, Robert ;
Sinhal, Ajay ;
Carere, Ronald G. ;
Munt, Brad ;
Ricci, Donald ;
Ye, Jian ;
Cheung, Anson ;
Lichtenstein, Sam V. .
CIRCULATION, 2007, 116 (07) :755-763
[19]   Transcatheter Aortic Valve Implantation Impact on Clinical and Valve-Related Outcomes [J].
Webb, John G. ;
Altwegg, Lukas ;
Boone, Robert H. ;
Cheung, Anson ;
Ye, Jian ;
Lichtenstein, Samuel ;
Lee, May ;
Masson, Jean Bernard ;
Thompson, Christopher ;
Moss, Robert ;
Carere, Ron ;
Munt, Brad ;
Nietlispach, Fabian ;
Humphries, Karin .
CIRCULATION, 2009, 119 (23) :3009-3016