Assessment of Automatically Exported Clinical Data from a Hospital Information System for Clinical Research in Multiple Myeloma

被引:2
作者
Torres, Viviana [1 ]
Cerda, Mauricio [2 ]
Knaup, Petra [3 ]
Loepprich, Martin [3 ,4 ]
机构
[1] Univ Chile, Fac Med, Program Master Med Informat, Santiago, Chile
[2] Univ Chile, Program Anat & Dev Biol, Ctr Med Informat & Telemed CIMT, BNI,ICBM,Fac Med, Santiago, Chile
[3] Heidelberg Univ, Inst Med Biometry & Informat, D-69115 Heidelberg, Germany
[4] Univ Heidelberg Hosp, Div Hematol Oncol Rheumatol, Dept Internal Med, Heidelberg, Germany
来源
EXPLORING COMPLEXITY IN HEALTH: AN INTERDISCIPLINARY SYSTEMS APPROACH | 2016年 / 228卷
关键词
electronic data capturing; automatic process; data collection; hospital information system;
D O I
10.3233/978-1-61499-678-1-332
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Purpose: An important part of the electronic information available in Hospital Information System (HIS) has the potential to be automatically exported to Electronic Data Capture (EDC) platforms for improving clinical research. This automation has the advantage of reducing manual data transcription, a time consuming and prone to errors process. However, quantitative evaluations of the process of exporting data from a HIS to an EDC system have not been reported extensively, in particular comparing with manual transcription. In this work an assessment to study the quality of an automatic export process, focused in laboratory data from a HIS is presented. Methods: Quality of the laboratory data was assessed in two types of processes: (1) a manual process of data transcription, and (2) an automatic process of data transference. The automatic transference was implemented as an Extract, Transform and Load (ETL) process. Then, a comparison was carried out between manual and automatic data collection methods. The criteria to measure data quality were correctness and completeness. Results: The manual process had a general error rate of 2.6% to 7.1%, obtaining the lowest error rate if data fields with a not clear definition were removed from the analysis (p < 10E-3). In the case of automatic process, the general error rate was 1.9% to 12.1%, where lowest error rate is obtained when excluding information missing in the HIS but transcribed to the EDC from other physical sources. Conclusion: The automatic ETL process can be used to collect laboratory data for clinical research if data in the HIS as well as physical documentation not included in HIS, are identified previously and follows a standardized data collection protocol.
引用
收藏
页码:332 / 336
页数:5
相关论文
共 11 条
  • [1] Defining and improving data quality in medical registries: A literature review, case study, and generic framework
    Arts, DGT
    de Keizer, NF
    Scheffer, GJ
    [J]. JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2002, 9 (06) : 600 - 611
  • [2] Bae CJ, 2015, EGEMS GENERATING EVI, V3, P1
  • [3] Benson T., 2012, Principles of Health Interoperability HL7 and SNOMED
  • [4] CPMP/ ICH, 1996, GOOD CLIN PRACT
  • [5] El Fadly AbdenNaji, 2011, J Biomed Inform, V44 Suppl 1, pS94, DOI 10.1016/j.jbi.2011.07.007
  • [6] Goldberg Saveli I, 2008, AMIA Annu Symp Proc, P242
  • [7] Hildebrand K., 2015, DATEN INFORMATIONSQU
  • [8] Secondary use of routinely collected patient data in a clinical trial: An evaluation of the effects on patient recruitment and data acquisition
    Koepcke, Felix
    Kraus, Stefan
    Scholler, Axel
    Nau, Carla
    Schuettler, Juergen
    Prokosch, Hans-Ulrich
    Ganslandt, Thomas
    [J]. INTERNATIONAL JOURNAL OF MEDICAL INFORMATICS, 2013, 82 (03) : 185 - 192
  • [9] Data management in clinical research: An overview
    Krishnankutty, Binny
    Bellary, Shantala
    Kumar, Naveen B. R.
    Moodahadu, Latha S.
    [J]. INDIAN JOURNAL OF PHARMACOLOGY, 2012, 44 (02) : 168 - 172
  • [10] Nahm ML, 2015, QUANTIFYING DATA QUA, V3