Comparative analysis of system performance of thermally integrated pumped thermal energy storage systems based on organic flash cycle and organic Rankine cycle

被引:34
|
作者
Wang, Penglai [1 ]
Li, Qibin [1 ]
Liu, Chao [1 ]
Wang, Ruiqiong [2 ]
Luo, Zhang [2 ]
Zou, Peng [2 ]
Wang, Shukun [3 ]
机构
[1] Chongqing Univ, Sch Energy & Power Engn, Key Lab Low Grade Energy Utilizat Technol & Syst, Minist Educ, Chongqing 400044, Peoples R China
[2] PowerChina Chongqing Engn Co Ltd, Chongqing 400060, Peoples R China
[3] Southwest Univ, Coll Engn & Technol, Chongqing 400715, Peoples R China
基金
中国国家自然科学基金;
关键词
Thermally integrated pumped thermal energy storage; Organic Rankine cycle; Organic flash cycle; Thermo-economic analysis; Multi-objective optimization; EXERGOECONOMIC ANALYSIS; THERMODYNAMIC ANALYSIS; ELECTRICAL ENERGY; EFFICIENCY;
D O I
10.1016/j.enconman.2022.116416
中图分类号
O414.1 [热力学];
学科分类号
摘要
Pumped thermal energy storage (PTES) technology has become an increasingly attractive research field because of its low cost, long lifetime, and lack of geographical restrictions. However, thermally integrated PTES (TIPTES) systems that integrate low-grade heat sources are more promising because they can significantly improve system performance. In this study, TIPTES systems driven by geothermal water employ the organic flash cycle (OFC-TIPTES) and organic Rankine cycle (ORC-TIPTES) as discharge cycles. Five different working fluids, including R123, Butane, Cyclohexane, R1233zd(E), and Butene, are selected as candidates. Parametric study is performed to analyze the effects of main parameters on system thermodynamic and thermo-economic performance. Then, comparative study is conducted based on the multi-objective optimization resutls to search out the optimal cycle structure and working fluid. Results indicate that when the thermal storage temperature increases, the variation trends of the exergy efficiency and levelized cost of storage (LCOS) are identical, but the variation trends of the power-to-power efficiency are different for two systems. And a higher evaporation temperature increases the thermodynamic efficiency of both systems. For the OFC-TIPTES system, a maximal thermodynamic efficiency exists at an optimal flash temperature. The multi-objective optimization results indicate that the ORC-TIPTES has higher power-to-power efficiency, exergy efficiency, and lower LCOS than the OFC-TIPTES. Butane and Cyclo-hexane yield the final solutions for power-to-power efficiency and LCOS for the OFC-TIPTES (33.55 % and 0.83 $.kWh(-1)) and the ORC-TIPTES (68.42 % and 0.34 $.kWh(-1)), respectively. The exergy destructions of the throttle valve before the flash tank and condenser of the heat-pump cycle are maximal, that is, 232 kW and 692 kW for the OFC-TIPTES and ORC-TIPTES systems, respectively. The costs of the condenser of the OFC/ORC subsystem, turbine, and compressor are higher for all components of both systems. A comparative analysis shows that the ORC-TIPTES system exhibits better performance than the OFC-TIPTES system in terms of thermodynamics and economics.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Thermal analysis of solar energy based organic Rankine cycle cascaded with vapor compression refrigeration cycle
    Qureshi, Mohammad Faizan
    Chandio, Mohammad Waqas
    Memon, Abdul Aleem
    Kumar, Laveet
    Awad, Mohamed M.
    ENERGY NEXUS, 2024, 14
  • [22] Energy analysis of cyclic parameters of organic Rankine cycle system
    Yan, Jinglu
    Jia, Wenguang
    Li, Kunling
    Yu, Hang
    Guo, Xianpei
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2021, 16 (02) : 341 - 350
  • [23] Analysis of Liquid Air Energy Storage System with Organic Rankine Cycle and Heat Regeneration System
    Umyshev, Dias Raybekovich
    Osipov, Eduard Vladislavovich
    Kibarin, Andrey Anatolievich
    Korobkov, Maxim Sergeyevich
    Petukhov, Yuriy Viktorovich
    SUSTAINABILITY, 2024, 16 (13)
  • [24] Exergoeconomic analysis of an integrated electric power generation system based on biomass energy and Organic Rankine cycle
    Azish, Ehsan
    Assareh, Ehsanolah
    Azizimehr, Behzad
    Lee, Moonyong
    AUSTRALIAN JOURNAL OF MECHANICAL ENGINEERING, 2025, 23 (01) : 149 - 160
  • [25] Thermal energy storage for solar-powered organic Rankine cycle engines
    Casati, E.
    Galli, A.
    Colonna, P.
    SOLAR ENERGY, 2013, 96 : 205 - 219
  • [26] Cold Energy Utilization in LNG Regasification System Using Organic Rankine Cycle and Trilateral Flash Cycle
    Daniarta, Sindu
    Imre, Attila R.
    PERIODICA POLYTECHNICA-MECHANICAL ENGINEERING, 2020, 64 (04): : 342 - 349
  • [27] Thermodynamic and economic analysis of organic Rankine cycle combined with flash cycle and ejector
    Niu, Jintao
    Wang, Jiansheng
    Liu, Xueling
    ENERGY, 2023, 282
  • [28] Thermodynamic analysis of a High Temperature Pumped Thermal Electricity Storage (HT-PTES) integrated with a parallel organic Rankine cycle (ORC)
    Chen, Long Xiang
    Hu, Peng
    Zhao, Pan Pan
    Xie, Mei Na
    Wang, Feng Xiang
    ENERGY CONVERSION AND MANAGEMENT, 2018, 177 : 150 - 160
  • [29] Performance analysis of transcritical organic rankine cycle
    Gao, Hong
    Liu, Chao
    He, Chao
    Xu, Xiaoxiao
    Chongqing Daxue Xuebao/Journal of Chongqing University, 2012, 35 (12): : 57 - 61
  • [30] Evaluation on energy performance in a low temperature district heating system integrated with organic Rankine cycle
    Wang, Hai
    Wang, Hai-ying
    Zhu, Tong
    Gao, Nai-ping
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2018, 19 (06): : 461 - 478