Shape of the anterior cornea: Comparison of height data from 4 corneal topographers

被引:30
作者
de Jong, Tim [1 ]
Sheehan, Matthew T. [3 ]
Dubbelman, Michiel [2 ]
Koopmans, Steven A. [1 ]
Jansonius, Nomdo M. [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Ophthalmol, Groningen, Netherlands
[2] Vrije Univ Amsterdam Med Ctr, Dept Phys & Med Technol, Amsterdam, Netherlands
[3] Natl Univ Ireland Galway, Galway, Ireland
关键词
OPTICAL ABERRATIONS; ACCURACY; MODEL; AGREEMENT; SURFACE; EYE;
D O I
10.1016/j.jcrs.2013.04.032
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the ability of clinical corneal topographers to describe the shape of the anterior cornea for optical modeling. SETTING: University Medical Center Groningen, Groningen, Netherlands. DESIGN: Cross-sectional study. METHODS: The anterior corneal shape of healthy subjects was assessed with 4 topographers (Atlas Placido disk, Galilei dual Scheimpflug, Orbscan scanning slit, Pentacam single Scheimpflug). Exported height data were fit with Zernike polynomials. Mean values with the standard deviation, interdevice variability, and test-retest variability were determined for the defocus Z(2,0), astigmatism Z(2,-2) and Z(2,2), coma Z(3,-1) and Z(3,1), and spherical aberration Z(4,0) coefficients for 5.5 mm and 8.0 mm diameters. RESULTS: At 5.5 mm, the single Scheimpflug topographer showed the smallest coefficient of repeatability; 0.31 mu m for Z(2,0); 0.40 and 0.34 mu m for Z(2,-2) and Z(2,2), respectively; 0.15 and 0.11 mu m for Z(3,-1) and Z(3,1), respectively; and 0.08 mu m for Z(4,0); the other topographers showed up to 10 times larger coefficients of repeatability. The (unsigned) mean differences between the topographers were in the range of 0.20 to 1.21 mu m for Z(2,0); 0.02 to 0.31 mu m and 0.06 to 0.42 mu m for Z(2,-2) and Z(2,2), respectively; 0.03 to 0.18 mu m and 0.03 to 0.35 mu m for Z(3,-1) and Z(3,1), respectively; and 0.00 to 0.14 mu m for Z(4,0). The Placido-disk topographer and single Scheimpflug topographer data corresponded best. Similar trends were found at 8.0 mm. CONCLUSION: Test-retest variability hampered a detailed description of the anterior corneal shape at the level of individual subjects; interdevice variability compromises the exchangeability of the devices.
引用
收藏
页码:1570 / 1580
页数:11
相关论文
共 32 条
[1]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]   Contributions of the cornea and the lens to the aberrations of the human eye [J].
Artal, P ;
Guirao, A .
OPTICS LETTERS, 1998, 23 (21) :1713-1715
[3]  
Atchison DA, 2000, Optics of the human eye, V35, DOI DOI 10.1016/B978-0-7506-3775-6.50022-5
[4]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Accuracy of Zernike polynomials in characterizing optical aberrations and the corneal surface of the eye [J].
Carvalho, LA .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (06) :1915-1926
[7]  
Doménech B, 2009, OPT PURA APL, V42, P51
[8]   The shape of the anterior and posterior surface of the aging human cornea [J].
Dubbelman, M ;
Sicarn, VADP ;
Van der Heijde, GL .
VISION RESEARCH, 2006, 46 (6-7) :993-1001
[9]   Corneal wave aberration from videokeratography: accuracy and limitations of the procedure [J].
Guirao, A ;
Artal, P .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2000, 17 (06) :955-965
[10]  
Gullstrand A, 1962, HELMHOLTZS TREATISE, V1, p[301, 382]