Reusable gold nanoparticle enhanced QCM immunosensor for detecting C-reactive protein

被引:30
作者
Ding, Pengfei [1 ]
Liu, Ruxiu [1 ]
Liu, Shihui [1 ]
Mao, Xueyin [1 ]
Hu, Ruifen [1 ]
Li, Guang [1 ]
机构
[1] Zhejiang Univ, Inst Cyber Syst & Control, Natl Lab Ind Control Technol, Hangzhou 310027, Zhejiang, Peoples R China
关键词
QCM; CRP; AuNP; Sensitivity enhancement; QUARTZ-CRYSTAL MICROBALANCE; CRP; IMMUNOASSAY; MARKERS; ASSAY;
D O I
10.1016/j.snb.2013.07.099
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This report describes a novel method to realize high sensitive C-reactive protein (hs-CRP) by using a quartz crystal microbalance (QCM) immunosensor based on 20 nm gold nanoparticles conjugated anti-CRP antibodies. A sandwich-type assay was established: CRP was firstly recognized by the anti-CRP antibody which was immobilized on the gold electrode of the QCM and the sensitivity was enhanced further by binding AuNP conjugated anti-CRP antibody secondly. The response of the QCM is observed to be linearly relative to the CRP concentration in the range of 20 ng/mL to 30 mu g/mL and the detection limit is enhanced to a great extend by the amplification procedure. The sensor was regenerated online by the solution of 3 mol/L Urea while preserving the activity of the immunosensor. (C) 2013 Elsevier B. V. All rights reserved.
引用
收藏
页码:1277 / 1283
页数:7
相关论文
共 30 条
[1]   FORMATION OF MONOLAYER FILMS BY THE SPONTANEOUS ASSEMBLY OF ORGANIC THIOLS FROM SOLUTION ONTO GOLD [J].
BAIN, CD ;
TROUGHTON, EB ;
TAO, YT ;
EVALL, J ;
WHITESIDES, GM ;
NUZZO, RG .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1989, 111 (01) :321-335
[2]   High-sensitivity C-reactive protein: Clinical importance [J].
Bassuk, SS ;
Rifai, N ;
Ridker, PM .
CURRENT PROBLEMS IN CARDIOLOGY, 2004, 29 (08) :439-493
[3]   C-reactive protein [J].
Black, S ;
Kushner, I ;
Samols, D .
JOURNAL OF BIOLOGICAL CHEMISTRY, 2004, 279 (47) :48487-48490
[4]   Electrochemical impedance immunosensor based on three-dimensionally ordered macroporous gold film [J].
Chen, Xiaojun ;
Wang, Yuanyuan ;
Zhou, Jinjun ;
Yan, Wei ;
Li, Xinghua ;
Zhu, Jun-Jie .
ANALYTICAL CHEMISTRY, 2008, 80 (06) :2133-2140
[5]   Quartz crystal microbalance immunoassay with dendritic amplification using colloidal gold immunocomplex [J].
Chu, X ;
Zhao, ZL ;
Shen, GL ;
Yu, RQ .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 114 (02) :696-704
[6]   Human chorionic gonadotropin interactions with immobilized anti-hCG studied by quartz-crystal microbalance with dissipation monitoring [J].
Chung, Natalie N. ;
Hamlin, Rebecca E. ;
Zwang, Theodore J. ;
Johal, Malkiat S. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2012, 100A (06) :1600-1604
[7]   A Nanostructured Piezoelectric Immunosensor for Detection of Human Cardiac Troponin T [J].
Fonseca, Rosana A. S. ;
Ramos-Jesus, Joilson ;
Kubota, Lauro T. ;
Dutra, Rosa F. .
SENSORS, 2011, 11 (11) :10785-10797
[8]   Electrochemical investigations of the interaction of C-reactive protein (CRP) with a CRP antibody chemically immobilized on a gold surface [J].
Hennessey, Hooman ;
Afara, Nadia ;
Omanovic, Sasha ;
Padjen, Ante L. .
ANALYTICA CHIMICA ACTA, 2009, 643 (1-2) :45-53
[9]   "Macromolecules to PDMS transfer" as a general route for PDMS biochips [J].
Heyries, Kevin A. ;
Mandon, Celine A. ;
Ceriotti, Laura ;
Ponti, Jessica ;
Colpo, Pascal ;
Blum, Loic J. ;
Marquette, Christophe A. .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (05) :1146-1152
[10]   Immunodetection of pentamer and modified C-reactive protein using surface plasmon resonance biosensing [J].
Hu, WP ;
Hsu, HY ;
Chiou, A ;
Tseng, KY ;
Lin, HY ;
Chang, GL ;
Chen, SJ .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (08) :1631-1637