Cobalt(II) ion-selective electrode with solid contact

被引:9
作者
Wardak, Cecylia [1 ]
机构
[1] Marie Curie Sklodowska Univ, Fac Chem, Dept Analyt Chem & Instrumental Anal, PL-20031 Lublin, Poland
来源
CENTRAL EUROPEAN JOURNAL OF CHEMISTRY | 2008年 / 6卷 / 04期
关键词
Cobalt-selective electrode; Potentiometry; Chelating agent; Flow injection analysis;
D O I
10.2478/s11532-008-0060-1
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A new all plastic sensor for Co2+ ions based on 2-amino-5 (hydroxynaphtyloazo-1')-1,3,4 thiadiazole (ATIDAN) as ionophore was prepared. The electrode exhibits a low detection limit of 1.5 x 10(-6) mol L-1 and almost theoretical Nernstian slope in the activity range 4.0 x 10(-6)- 1 x 10(-1) mol L-1 of cobalt ions. The response time of the sensor is less than 10 s and it can be used over a period of 6 months without any measurable divergence in potential. The proposed sensor shows a fairly good selectivity for Co(II) over other metal ions. The electrode was successfully applied for determination of Co2+ in real samples and as an indicator electrode in potentiometric titration of Co2+ ions with EDTA.
引用
收藏
页码:607 / 612
页数:6
相关论文
共 50 条
[41]   Potentiometric determination of diazepam, bromazepam and clonazepam using solid contact ion-selective electrodes [J].
Salem, AA ;
Barsoum, BN ;
Izake, EL .
ANALYTICA CHIMICA ACTA, 2003, 498 (1-2) :79-91
[42]   Gold nanoparticles solid contact for ion-selective electrodes of highly stable potential readings [J].
Jaworska, Ewa ;
Wojcik, Michal ;
Kisiel, Anna ;
Mieczkowski, Jozef ;
Michalska, Agata .
TALANTA, 2011, 85 (04) :1986-1989
[43]   Ionic Liquids Improve Analytical Parameters of Cadmium Ion-Selective Electrodes with Solid Contact [J].
Wardak, Cecylia .
SENSOR LETTERS, 2012, 10 (3-4) :1000-1006
[44]   Determination of Thiocyanate Ion by Ion-selective Electrode Using Schiff Base Complex of Cu(II) as an Ionophore [J].
Singh, Sanjay ;
Singh, Aishwarya ;
Yadav, Kalash Chandra ;
Singh, Arpit ;
Singh, Gyanendra .
ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2012, 4 (02) :163-177
[45]   Using of hydrogen ion-selective poly(vinyl chloride) membrane electrode based on calix[4]arene as thiocyanate ion-selective electrode [J].
Erden, S ;
Demirel, A ;
Memon, S ;
Yilmaz, M ;
Canel, E ;
Kiliç, E .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 113 (01) :290-296
[46]   CONSTRUCTION AND EVALUATION OF A NOVEL GLAFENINE ION-SELECTIVE ELECTRODE [J].
AHMED, MA ;
ABBAS, AB .
ANALYTICAL LETTERS, 1995, 28 (01) :13-26
[47]   Wireless Ion-Selective Electrode Autonomous Sensing System [J].
Fay, Cormac ;
Anastasova, Salzitsa ;
Slater, Conor ;
Buda, Sandra Teodora ;
Shepherd, Roderick ;
Corcoran, Brian ;
O'Connor, Noel E. ;
Wallace, Gordon G. ;
Radu, Aleksandar ;
Diamond, Dermot .
IEEE SENSORS JOURNAL, 2011, 11 (10) :2374-2382
[48]   Ion-selective electrode for bismuth(III) in ethylenediamintetraacetate medium [J].
Teixeira, MFD ;
Pinto, AZ ;
Fatibello, O .
TALANTA, 1997, 45 (02) :249-255
[49]   POTENTIOMETRIC DETERMINATION OF DIAZEPAM WITH A DIAZEPAM ION-SELECTIVE ELECTRODE [J].
NIE, LH ;
LIU, DZ ;
YAO, SZ .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1990, 8 (04) :379-383
[50]   Dopamine ion-selective electrode for potentiometry in pharmaceutical preparations [J].
Lima, JLFC ;
Montenegro, MCBSM .
MIKROCHIMICA ACTA, 1999, 131 (3-4) :187-190