Cobalt(II) ion-selective electrode with solid contact

被引:9
作者
Wardak, Cecylia [1 ]
机构
[1] Marie Curie Sklodowska Univ, Fac Chem, Dept Analyt Chem & Instrumental Anal, PL-20031 Lublin, Poland
来源
CENTRAL EUROPEAN JOURNAL OF CHEMISTRY | 2008年 / 6卷 / 04期
关键词
Cobalt-selective electrode; Potentiometry; Chelating agent; Flow injection analysis;
D O I
10.2478/s11532-008-0060-1
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A new all plastic sensor for Co2+ ions based on 2-amino-5 (hydroxynaphtyloazo-1')-1,3,4 thiadiazole (ATIDAN) as ionophore was prepared. The electrode exhibits a low detection limit of 1.5 x 10(-6) mol L-1 and almost theoretical Nernstian slope in the activity range 4.0 x 10(-6)- 1 x 10(-1) mol L-1 of cobalt ions. The response time of the sensor is less than 10 s and it can be used over a period of 6 months without any measurable divergence in potential. The proposed sensor shows a fairly good selectivity for Co(II) over other metal ions. The electrode was successfully applied for determination of Co2+ in real samples and as an indicator electrode in potentiometric titration of Co2+ ions with EDTA.
引用
收藏
页码:607 / 612
页数:6
相关论文
共 50 条
[31]   A new ion-selective electrode for anionic surfactants [J].
Segui, Ma Jesus ;
Lizondo-Sabater, Josefa ;
Benito, Angel ;
Martinez-Manez, Ramon ;
Pardo, Teresa ;
Sancenon, Fix ;
Soto, Juan .
TALANTA, 2007, 71 (01) :333-338
[32]   DEVELOPMENT OF A GRAPHENE PAPER-BASED FLEXIBLE SOLID-CONTACT LEAD ION-SELECTIVE ELECTRODE AND ITS APPLICATION IN WATER [J].
Yao, Y. ;
Ying, Y. ;
Ping, J. .
TRANSACTIONS OF THE ASABE, 2019, 62 (02) :245-252
[33]   Stable Pb(II) ion-selective electrodes with a low detection limit using silver nanoparticles/polyaniline as the solid contact [J].
Zeng, Xianghua ;
Jiang, Wenwen ;
Waterhouse, Geoffrey I. N. ;
Jiang, Xiaohui ;
Zhang, Zhiming ;
Yu, Liangmin .
MICROCHIMICA ACTA, 2021, 188 (11)
[34]   A hydrogen ion-selective poly(vinyl chloride) membrane electrode based on calix[4]arene as a perchlorate ion-selective electrode [J].
Canel, Esin ;
Erden, Sevcan ;
Ozel, Ayca Demirel ;
Memon, Sahahabuddin ;
Yilmaz, Mustafa ;
Kilic, Esma .
TURKISH JOURNAL OF CHEMISTRY, 2008, 32 (03) :323-332
[35]   Stable Pb(II) ion-selective electrodes with a low detection limit using silver nanoparticles/polyaniline as the solid contact [J].
Xianghua Zeng ;
Wenwen Jiang ;
Geoffrey I. N. Waterhouse ;
Xiaohui Jiang ;
Zhiming Zhang ;
Liangmin Yu .
Microchimica Acta, 2021, 188
[36]   Preparation of a solid-state ion-selective electrode based on polypyrrole conducting polymer for magnesium ion [J].
Zahra Mosayebzadeh ;
Reza Ansari ;
Majid Arvand .
Journal of the Iranian Chemical Society, 2014, 11 :447-456
[37]   Preparation of a solid-state ion-selective electrode based on polypyrrole conducting polymer for magnesium ion [J].
Mosayebzadeh, Zahra ;
Ansari, Reza ;
Arvand, Majid .
JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2014, 11 (02) :447-456
[38]   Cobalt(II) ion detection in electroplating wastewater by a new cobalt ion-selective electrode based on N'-[1-(2-thienyl)ethylidene]-2-furohydrazide [J].
Zamani, Hassan Ali ;
Ganjali, Mohammad Reza ;
Norouzi, Parviz ;
Adib, Mahdi .
SENSOR LETTERS, 2007, 5 (3-4) :522-527
[39]   Calibration-free potentiometric sensing with solid-contact ion-selective electrodes [J].
Rousseau, Celeste R. ;
Buhlmann, Philippe .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2021, 140
[40]   Metal oxide nanoparticles as solid contact in ion-selective electrodes sensitive to potassium ions [J].
Pietrzak, Karolina ;
Krstulovic, Niksa ;
Blazeka, Damjan ;
Car, Julio ;
Malinowski, Szymon ;
Wardak, Cecylia .
TALANTA, 2022, 243