摘要
A new all plastic sensor for Co2+ ions based on 2-amino-5 (hydroxynaphtyloazo-1')-1,3,4 thiadiazole (ATIDAN) as ionophore was prepared. The electrode exhibits a low detection limit of 1.5 x 10(-6) mol L-1 and almost theoretical Nernstian slope in the activity range 4.0 x 10(-6)- 1 x 10(-1) mol L-1 of cobalt ions. The response time of the sensor is less than 10 s and it can be used over a period of 6 months without any measurable divergence in potential. The proposed sensor shows a fairly good selectivity for Co(II) over other metal ions. The electrode was successfully applied for determination of Co2+ in real samples and as an indicator electrode in potentiometric titration of Co2+ ions with EDTA.
引用
收藏
页码:607 / 612
页数:6
相关论文
共 50 条
[21]   Recent Developments and Challenges in Solid-Contact Ion-Selective Electrodes [J].
Gao, Lili ;
Tian, Ye ;
Gao, Wenyue ;
Xu, Guobao .
SENSORS, 2024, 24 (13)
[22]   Novel usage of perinone polymer as solid contact in ion-selective electrodes [J].
Morawskaa, Klaudia ;
Czichyb, Malgorzata ;
Janasikb, Patryk ;
Lapkowskib, Mieczyslaw ;
Wardak, Cecylia .
SENSORS AND ACTUATORS B-CHEMICAL, 2025, 422
[23]   Ion-Selective Electrodes with Solid Contact Based on Composite Materials: A Review [J].
Wardak, Cecylia ;
Pietrzak, Karolina ;
Morawska, Klaudia ;
Grabarczyk, Malgorzata .
SENSORS, 2023, 23 (13)
[24]   A mercury(II) ion-selective electrode based on neutral salicylaldehyde thiosemicarbazone [J].
Mahajan, RK ;
Kaur, I ;
Lobana, TS .
TALANTA, 2003, 59 (01) :101-105
[25]   A Solid-Contact Ion Selective Electrode for Copper(II) Using a Succinimide Derivative as Ionophore [J].
Tutulea-Anastasiu, Mihaela Dana ;
Wilson, Deivy ;
del Valle, Manel ;
Schreiner, Cristina Mihaela ;
Cretescu, Igor .
SENSORS, 2013, 13 (04) :4367-4377
[26]   Novel solid-contact ion-selective electrode based on a polyaniline transducer layer for determination of alcaftadine in biological fluid [J].
Hussein, Ola G. G. ;
Ahmed, Dina A. A. ;
Abdelkawy, Mohamed ;
Rezk, Mamdouh R. R. ;
Mahmoud, Amr M. M. ;
Rostom, Yasmin .
RSC ADVANCES, 2023, 13 (11) :7645-7655
[27]   Direct Potentiometry of Polyacrylate with Solid-Membrane Cadmium Ion-Selective Electrode [J].
Ichikawa, Takanori ;
Yasui, Takashi ;
Takada, Kazutake ;
Yuchi, Akio .
BUNSEKI KAGAKU, 2009, 58 (08) :749-752
[28]   DETERMINATION OF SULFUR IN SOLID AND LIQUID SAMPLES BY POTENTIOMETRIC TITRATION WITH ION-SELECTIVE ELECTRODE [J].
DEMEDINA, HL ;
GONZALEZ, G ;
DURAN, J .
ANALYTICAL LETTERS, 1994, 27 (03) :625-641
[29]   A Comparative Study of Cadmium Ion-Selective Electrodes with Solid and Liquid Inner Contact [J].
Wardak, Cecylia .
ELECTROANALYSIS, 2012, 24 (01) :85-90
[30]   A Novel Ion-Selective Electrode for Determination of the Mercury(II) Ion Based on Schiff Base as a Carrier [J].
Zhang, M. ;
Wu, X. ;
Chai, Y. Q. ;
Yuan, R. ;
Ye, G. R. .
JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2008, 55 (06) :1345-1350