Experimental investigation of adjacent buildings connected by fluid damper

被引:0
|
作者
Xu, YL [1 ]
Zhan, S [1 ]
Ko, JM [1 ]
Zhang, WS [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Civil & Struct Engn, Kowloon, Peoples R China
来源
关键词
experimental investigation; adjacent buildings; fluid damper; dynamic characteristic; harmonic response;
D O I
10.1002/(SICI)1096-9845(199906)28:6<609::AID-EQE831>3.0.CO;2-S
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Dynamic characteristic and harmonic response of adjacent buildings connected by fluid damper were experimentally investigated using model buildings and fluid damper. Two building models were constructed as two three-storey shear buildings of different natural frequencies. Model fluid damper connecting the two buildings was designed as linear viscous damper of which damping coefficient could be adjusted. The two buildings without fluid dampers connected were first tested to obtain their individual dynamic characteristics and responses to harmonic excitation, The tests were then carried out to determine modal damping ratios of the adjacent buildings connected by the fluid damper of different damping coefficients and at different locations. Optimal damper damping coefficient and location for achieving the maximum modal damping ratio were thus found. The measured modal damping ratios and harmonic responses of the building-fluid damper system were finally compared with those from the individual buildings. The comparison showed that the fluid damper of proper parameter could significantly increase the modal damping ratio and tremendously reduce the dynamic response of both buildings. Copyright (C) 1999 John Wiley & Sons, Ltd.
引用
收藏
页码:609 / 631
页数:23
相关论文
共 50 条
  • [1] Experimental investigation of adjacent buildings connected by fluid damper
    Xu, Y.L.
    Zhan, S.
    Ko, J.M.
    Zhang, W.S.
    Earthquake Engineering and Structural Dynamics, 1999, 28 (06): : 609 - 631
  • [2] Dynamic response of damper-connected adjacent buildings under earthquake excitation
    Xu, YL
    He, Q
    Ko, JM
    ENGINEERING STRUCTURES, 1999, 21 (02) : 135 - 148
  • [3] Dynamic analyses of adjacent buildings connected by fluid viscous dampers
    Uz, M. E.
    Hadi, M. N. S.
    EARTHQUAKE RESISTANT ENGINEERING STRUCTURES VII, 2009, 104 : 139 - 150
  • [4] Optimizing damper connectors for adjacent buildings
    Bigdeli, K.
    Hare, W.
    Nutini, J.
    Tesfamariam, S.
    OPTIMIZATION AND ENGINEERING, 2016, 17 (01) : 47 - 75
  • [5] Optimizing damper connectors for adjacent buildings
    K. Bigdeli
    W. Hare
    J. Nutini
    S. Tesfamariam
    Optimization and Engineering, 2016, 17 : 47 - 75
  • [6] Experimental seismic study of adjacent buildings with fluid dampers
    Yang, Z
    Xu, YL
    Lu, XL
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2003, 129 (02): : 197 - 205
  • [7] Damping reduction factors for adjacent buildings connected by fluid-viscous dampers
    Palermo, Michele
    Silvestri, Stefano
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2020, 138
  • [8] Modeling and experimental investigation of a controllable rotary fluid damper
    Cao, X.
    Zhou, J.
    Yu, M.
    Wang, Y.
    ARCHIVES OF MECHANICS, 2023, 75 (04): : 493 - 516
  • [9] Fluid flow modeling and experimental investigation on automobile damper
    Jugulkar, Lalitkumar Maikulal
    Singh, Shankar
    Sawant, Suresh M.
    CONSTRUCTION AND BUILDING MATERIALS, 2016, 121 : 760 - 772
  • [10] Experimental Investigation of Nonlinear Characteristics of a Smart Fluid Damper
    Rahman, Mahmudur
    Ong, Zhi Chao
    Chong, Wen Tong
    Julai, Sabariah
    Ahamed, Raju
    3RD INTERNATIONAL CONFERENCE ON THE SCIENCE AND ENGINEERING OF MATERIALS (ICOSEM 2017), 2018, 1958