Long-term stability of parameters of antioxidant status in human serum

被引:25
|
作者
Jansen, E. H. J. M. [1 ]
Beekhof, P. K. [1 ]
Cremers, J. W. J. M. [1 ]
Viezeliene, D. [2 ]
Muzakova, V. [3 ]
Skalicky, J. [4 ]
机构
[1] Natl Inst Publ Hlth & Environm, Ctr Hlth Protect, NL-3720 BA Bilthoven, Netherlands
[2] Lithuanian Univ Hlth Sci, Med Acad, Dept Biochem, Kaunas, Lithuania
[3] Univ Pardubice, Fac Chem Technol, Dept Biol & Biochem Sci, Pardubice, Czech Republic
[4] Reg Hosp Pardubice, Dept Clin Biochem & Diagnost, Pardubice, Czech Republic
关键词
total antioxidant status; storage; uric acid; creatinine; bilirubin; OXIDATIVE STRESS; CAPACITY; CAROTENOIDS; MARKERS; STORAGE; CANCER; RISK;
D O I
10.3109/10715762.2013.797969
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The antioxidant status of serum or plasma can be determined using several commercially available assays. Here, four different assays, total antioxidant status (TAS), its second-generation assay (TAS2), biological antioxidant potential (BAP), and enzymatic assay using horseradish peroxidase (EAOC), were applied on human serum samples to test the temperature stability of antioxidants, upon storage of serum for 12 months. The two or three most commonly used temperatures for storage, that is, -20, -70 (or -80), and -196 degrees C, were selected. The general conclusion is that all assays were stable at the temperatures tested. In addition, there were almost no statistically significant differences between the samples stored at different temperatures. Only the rank order of the EAOC assay was not very good in samples stored at -20 degrees C. Also three components contributing to the total antioxidant capacity, uric acid, creatinine and bilirubin, showed no statistically significant differences between the temperatures. Therefore, storage at -20 degrees C is sufficient to maintain a proper assay outcome of most of the total antioxidant assays, although storage at -70/80 degrees C is to be preferred for longer storage times.
引用
收藏
页码:535 / 540
页数:6
相关论文
共 50 条
  • [1] Long-term stability of biomarkers of the iron status in human serum and plasma
    Jansen, Eugene H. J. M.
    Beekhof, Piet K.
    Schenk, Erna
    BIOMARKERS, 2013, 18 (04) : 365 - 368
  • [2] Very long-term stability of lipid biomarkers in human serum
    Muzakova, Vladimira
    Beekhof, Piet K.
    Jansen, Eugene H. J. M.
    ANALYTICAL BIOCHEMISTRY, 2020, 597
  • [3] Long-term stability of oxidative stress biomarkers in human serum
    Jansen, Eugene H. J. M.
    Beekhof, Piet K.
    Viezeliene, Dale
    Muzakova, Vladimira
    Skalicky, Jiri
    FREE RADICAL RESEARCH, 2017, 51 (11-12) : 970 - 977
  • [4] LONG-TERM STABILITY OF HORMONES IN SERUM
    VASILIADES, J
    HILGERS, T
    GENTRUP, B
    CLINICAL CHEMISTRY, 1995, 41 (06) : S59 - S59
  • [5] Long-term Stability of Circulating Nucleosomes in Serum
    Holdenrieder, Stefan
    Von Pawel, Joachim
    Nagel, Dorothea
    Stieber, Petra
    ANTICANCER RESEARCH, 2010, 30 (05) : 1613 - 1615
  • [6] STABILITY OF THE ESTIMATES OF THE PARAMETERS OF THE LONG-TERM STRENGTH
    LOGINOV, EA
    TRUNIN, II
    INDUSTRIAL LABORATORY, 1987, 53 (07): : 661 - 664
  • [7] Long-term stability of serum components in the Janus Serum Bank
    Gislefoss, Randi E.
    Grimsrud, Tom K.
    Morkrid, Lars
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2008, 68 (05): : 402 - 409
  • [8] Long-term (in)stability of folate and vitamin B12 in human serum
    Jansen, Eugene H. J. M.
    Beekhof, Piet K.
    Cremers, Johannes W. J. M.
    Schenk, Erna
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2012, 50 (10) : 1761 - 1763
  • [9] The impact of chronic untreated hyperglycaemia on the long-term stability of paraoxonase 1 (PON1) and antioxidant status in human sera
    Macharia, Muiruri
    Kengne, Andre P.
    Blackhurst, Diane M.
    Erasmus, Rajiv T.
    Matsha, Tandi E.
    JOURNAL OF CLINICAL PATHOLOGY, 2014, 67 (01) : 55 - 59
  • [10] Serum mineral status of long-term cigarette smokers
    Meral, Ismail
    Akdemir, Fazile Nur Ekinci
    TOXICOLOGY AND INDUSTRIAL HEALTH, 2015, 31 (01) : 92 - 96