Comparative study of image quality between axial T2-weighted BLADE and turbo spin-echo MRI of the upper abdomen on 3.0 T

被引:21
作者
Zhang, Lin [1 ,2 ]
Tian, ChunMei [3 ]
Wang, PeiYuan [2 ]
Chen, Liang [2 ]
Mao, Xijin [2 ]
Wang, ShanShan [2 ]
Wang, Xu [2 ]
Dong, JingMin [2 ]
Wang, Bin [4 ]
机构
[1] Shandong Univ, Shandong Med Imaging Res Inst, Jinan 250021, Shandong, Peoples R China
[2] Binzhou Med Univ, Affiliated Hosp, Dept Radiol, Binzhou 256603, Shandong, Peoples R China
[3] Binzhou Med Univ, Affiliated Hosp, Dept Pediat, Binzhou 256603, Shandong, Peoples R China
[4] Binzhou Med Univ, Yantai 264003, Shandong, Peoples R China
关键词
MRI; BLADE; PROPELLER; Image artifact; MOTION CORRECTION; FEMALE PELVIS; PROPELLER; ARTIFACT;
D O I
10.1007/s11604-015-0463-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare image quality of turbo spin-echo (TSE) with BLADE [which is also named periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER)] on magnetic resonance imaging (MRI) for upper abdomen. This study involved the retrospective evaluation of 103 patients (63 males, 40 females; age range 19-76 years; median age 53.8 years) who underwent 3.0 T MRI with both conventional TSE T2-weighted imaging (T2WI) and BLADE TSE T2WI. Two radiologists assessed respiratory motion, gastrointestinal peristalsis, and vascular pulsation artifacts, as well as the sharpness of the liver and pancreas edges. Scores for all magnetic resonance (MR) images were recorded. Wilcoxon's rank test was used to compare hierarchical data. Cohen's kappa coefficient was adopted to analyze interobserver consistency. Compared to TSE T2WI, BLADE TSE T2WI reduced all of the examined motion artifacts and increased the sharpness of the liver and pancreas edges (all P < 0.05). Medium to good interobserver consistency was obtained for evaluating these indicators. The scanning time of BLADE TSE T2WI was 4-16 s shorter than that of conventional TSE T2WI. Compared to TSE sequence, the BLADE technique can reduce the respiratory motion, gastrointestinal peristalsis, and vascular pulsation artifacts, while decreasing the scanning time and improving the anatomic detail and image quality.
引用
收藏
页码:585 / 590
页数:6
相关论文
共 22 条
  • [11] GESFIDE-PROPELLER Approach for Simultaneous R2 and R2* Measurements in the Abdomen
    Jin, Ning
    Guo, Yang
    Zhang, Zhuoli
    Zhang, Longjiang
    Lu, Guangming
    Larson, Andrew C.
    [J]. MAGNETIC RESONANCE IMAGING, 2013, 31 (10) : 1760 - 1765
  • [12] Comparison of Sagittal T2-Weighted BLADE and Fast Spin-Echo MRI of the Female Pelvis for Motion Artifact and Lesion Detection
    Lane, Barton F.
    Vandermeer, Fauzia Q.
    Oz, Rasim C.
    Irwin, Eric W.
    McMillan, Alan B.
    Wong-You-Cheong, Jade J.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (02) : W307 - W313
  • [13] Comparison of PD BLADE with fat saturation (FS), PD FS and T2 3D DESS with water excitation (WE) in detecting articular knee cartilage defects
    Lavdas, Eleftherios
    Topalzikis, Theofilos
    Mavroidis, Panayiotis
    Kyriakis, Ioannis
    Roka, Violeta
    Kostopoulos, Spiros
    Glotsos, Dimitrios
    Zilidis, Christos
    Stathakis, Sotiris
    Tsagkalis, Antonios
    Papanikolaou, Nikos
    Batsikas, Georgios
    Arvanitis, Dimitrios L.
    Vassiou, Katerina
    [J]. MAGNETIC RESONANCE IMAGING, 2013, 31 (08) : 1255 - 1262
  • [14] The role of diffusion-weighted magnetic resonance imaging in cholesteatoma diagnosis and follow-up. Study with the diffusion PROPELLER technique
    Mateos-Fernandez, Manuel
    Mas-Estelles, Fernando
    de Paula-Vernetta, Carlos
    Guzman-Calvete, Abel
    Villanueva-Marti, Ricardo
    Morera-Perez, Constantino
    [J]. ACTA OTORRINOLARINGOLOGICA ESPANOLA, 2012, 63 (06): : 436 - 442
  • [15] Renal T2-weighted turbo-spin-echo imaging with BLADE at 3.0 Tesla: Initial experience
    Michaely, Henrik J.
    Kramer, Harald
    Weckbach, Sabine
    Dietrich, Olaf
    Reiser, Maximilian F.
    Schoenberg, Stefan O.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (01) : 148 - 153
  • [16] Diagnostic pitfalls and artifacts in abdominal MR imaging: A review
    Mirowitz, SA
    [J]. RADIOLOGY, 1998, 208 (03) : 577 - 589
  • [17] Pipe JG, 1999, MAGNET RESON MED, V42, P963, DOI 10.1002/(SICI)1522-2594(199911)42:5<963::AID-MRM17>3.0.CO
  • [18] 2-L
  • [19] Rofsky Neil M, 2014, Top Magn Reson Imaging, V23, P71, DOI 10.1097/RMR.0000000000000020
  • [20] 3D GRASE PROPELLER: Improved Image Acquisition Technique for Arterial Spin Labeling Perfusion Imaging
    Tan, Huan
    Hoge, W. Scott
    Hamilton, Craig A.
    Guenther, Matthias
    Kraft, Robert A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (01) : 168 - 173