Image resolution of the Lunar Expert-XL

被引:11
作者
Thorpe, JA [1 ]
Steel, SA [1 ]
机构
[1] Hull Royal Infirm, Ctr Metab Bone Dis, Hull HU3 2RW, N Humberside, England
关键词
expert-XL; densitometry; DXA; quality assurance; resolution;
D O I
10.1007/s001980050201
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The Lunar Expert-XL is an example of the latest generation of fan beam densitometers, with the X-ray source and detector array mounted on a C-arm to enable supine lateral imaging. Image resolution for anteroposterior (AP) spine, femur, hand, forearm and lateral morphometry on the Expert-XL were assessed in vitro with the 07-541 Nuclear Associates line pair test pattern. Each scan type was investigated at all available tube currents and scan speeds, and at the maximum, minimum and default bed heights. The effect of soft tissue thickness on resolution was investigated by using varying amounts of Perspex attenuator. The in vitro median lateral (x-axis) resolutions at the default bed height for the default scan types were 0.9 line pairs (lps)/mm for the 5 mA fast AP spine and femur scans, and 1.0 lps/mm for 1 mA fast hand, forearm and 5 mA fast morphometry scans. This equates to a resolution of about 1 mm. The best resolution achieved was 1.2 lps/mm (0.83 mm), obtainable on all scan modes with the bed at maximum elevation, but only consistently with the forearm mode. Lower tube current did not affect resolution but did change the range of soft tissue thickness over which an image could be resolved. Turbo scan modes greatly reduced longitudinal (y-axis) resolution but had little effect on lateral resolution. This study demonstrates the importance of including an assessment of resolution when validating new equipment, especially if morphometric investigations are to be conducted.
引用
收藏
页码:95 / 101
页数:7
相关论文
共 10 条
[1]  
BARENHOLDT O, 1996, CURRENT RES OSTEOPOR, V4, P56
[2]   DUAL X-RAY ABSORPTIOMETRY - A COMPARISON BETWEEN FAN-BEAM AND PENCIL BEAM SCANS [J].
BLAKE, GM ;
PARKER, JC ;
BUXTON, FMA ;
FOGELMAN, I .
BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (790) :902-906
[3]   RECENT DEVELOPMENTS IN DXA - QUALITY OF NEW DXA/MXA-DEVICES FOR DENSITOMETRY AND MORPHOMETRY [J].
FELSENBERG, D ;
GOWIN, W ;
DIESSEL, E ;
ARMBRUST, S ;
MEWS, J .
EUROPEAN JOURNAL OF RADIOLOGY, 1995, 20 (03) :179-184
[4]   Correcting the magnification error of fan beam densitometers [J].
Griffiths, MR ;
Noakes, KA ;
Pocock, NA .
JOURNAL OF BONE AND MINERAL RESEARCH, 1997, 12 (01) :119-123
[5]   A preliminary evaluation of the Lunar Expert-XL for bone densitometry and vertebral morphometry [J].
Lang, T ;
Takada, M ;
Gee, R ;
Wu, C ;
Li, J ;
HayashiClark, C ;
Schoen, S ;
March, V ;
Genant, HK .
JOURNAL OF BONE AND MINERAL RESEARCH, 1997, 12 (01) :136-143
[6]  
PEEL NFA, 1995, J BONE MINER RES, V10, P1796
[7]   Morphometric X-ray absorptiometry: Reference data for vertebral dimensions [J].
Rea, JA ;
Steiger, P ;
Blake, GM ;
Potts, E ;
Smith, IG ;
Fogelman, I .
JOURNAL OF BONE AND MINERAL RESEARCH, 1998, 13 (03) :464-474
[8]   An assessment of the radiation dose to patients and staff from a Lunar Expert-XL fan beam densitometer [J].
Steel, SA ;
Baker, AJ ;
Saunderson, JR .
PHYSIOLOGICAL MEASUREMENT, 1998, 19 (01) :17-26
[9]   Development and evaluation of a phantom for morphometric X-ray absorptiometry [J].
Steel, SA ;
Thorpe, JA ;
Walker, R ;
Howey, S ;
Langton, CM .
OSTEOPOROSIS INTERNATIONAL, 1999, 9 (01) :38-44
[10]   A phantom based study on the effect of subject positioning on morphometric X-ray absorptiometry using the Lunar EXPERT-XL [J].
Thorpe, JA ;
Steel, SA ;
Langton, CM .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (851) :1153-1161