Real-time fouling characteristics of a typical heat exchanger used in the waste heat recovery systems

被引:107
作者
Wang, Fei-Long [1 ]
He, Ya-Ling [1 ]
Tong, Zi-Xiang [1 ]
Tang, Song-Zhen [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Key Lab Thermofluid Sci & Engn, Minist Educ, Xian 710049, Shaanxi, Peoples R China
关键词
Waste heat recovery; H-type finned tube; Fouling; Fouling resistance; Fouling time ratio; FINNED TUBE BANK; DEPOSITION CHARACTERISTICS; REMOVAL MECHANISMS; ASH DEPOSITION; 10; ROWS; PARTICLE; SURFACE; ADHESION; IMPACT; MODEL;
D O I
10.1016/j.ijheatmasstransfer.2016.08.112
中图分类号
O414.1 [热力学];
学科分类号
摘要
A numerical method was developed to investigate the fouling characteristics of a typical heat exchanger. Firstly, an integrated fouling model which consists of a deposition process and a removal process was developed to simulate the fouling characteristics. The deposition criterion was determined by the energy balance during the interaction of particle and surface, and the removal process was based on the local wall shear stress and the fouling thickness. Then, the fluid flow characteristics were calculated and the discrete phase model (DPM) was employed to trace the fly ash particles during the fouling process. Since the simulation time is much smaller in magnitude than the real time in fouling process, a fouling time ratio was proposed to enlarge the simulation time and results to the real time scale. The flow characteristics, real-time fouling characteristics and the effects of inlet velocity, particle diameter on the fouling resistance were investigated. At last, the comparison with experimental results was also conducted. The results show that the particle motion was easily controlled by different vortex structures and the fouling mainly occurred in the flow stagnation region and the recirculation region. The net fouling results shows an asymptotic characteristic of growth and the increase in inlet velocity and particle diameter would lead to a decrease in fouling results. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:774 / 786
页数:13
相关论文
共 37 条
[11]   Numerical calculation of the effect of deposit formation on heat-exchanger efficiency [J].
Bouris, D ;
Bergeles, G .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1997, 40 (17) :4073-4084
[12]   Experimental Investigation of Heat Transfer and Pressure Drop Characteristics of H-type Finned Tube Banks [J].
Chen, Heng ;
Wang, Yungang ;
Zhao, Qinxin ;
Ma, Haidong ;
Li, Yuxin ;
Chen, Zhongya .
ENERGIES, 2014, 7 (11) :7094-7104
[13]  
Gupta A. K., 2004, Part of: Statistics: A Series of Textbooks and Monographs
[14]   A numerical study of the deposition characteristics of sulfuric acid vapor on heat exchanger surfaces [J].
Han, H. ;
He, Y. L. ;
Tao, W. Q. .
CHEMICAL ENGINEERING SCIENCE, 2013, 101 :620-630
[15]   A parameter study of tube bundle heat exchangers for fouling rate reduction [J].
Han, Hui ;
He, Ya-Ling ;
Tao, Wen-Quan ;
Li, Yin-Shi .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 72 :210-221
[16]   Sulfuric acid deposition characteristics of H-type finned tube bank with 10 rows [J].
He, Ya-Ling ;
Han, Hui ;
Tang, Song-Zhen ;
Zhou, Tian .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 81 :137-141
[17]  
[何雅玲 He Yaling], 2016, [科学通报, Chinese Science Bulletin], V61, P1858
[18]   Parametric study and field synergy principle analysis of H-type finned tube bank with 10 rows [J].
Jin, Yu ;
Tang, Gui-Hua ;
He, Ya-Ling ;
Tao, Wen-Quan .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 60 :241-251
[19]  
Kern D.Q., 1959, BRITCHEMENG, V4, P258
[20]   Particle sticking/rebound criteria at oblique impact [J].
Konstandopoulos, AG .
JOURNAL OF AEROSOL SCIENCE, 2006, 37 (03) :292-305