Validity of the polar S810 heart rate monitor to measure R-R intervals at rest

被引:344
作者
Gamelin, Franicois Xavier
Berthoin, Serge
Bosquet, Laurent
机构
[1] Univ Montreal, Dept Kinesiol, Montreal, PQ H3C 3J7, Canada
[2] Univ Lille, Fac Sport Sci, Ronchin, France
关键词
heart rate variability; time domain analysis; frequency domain analysis; Poincare graph analysis;
D O I
10.1249/01.mss.0000218135.79476.9c
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: This study was conducted to compare R-R intervals and the subsequent analysis of heart rate variability (HRV) obtained front the Polar S810 heart rate monitor (HRM) (Polar Electro Oy) with ail electrocardiogram (ECG) (Physiotrace, Estaris. Lille, France) during an orthostatic test. Methods: A total of 18 healthy men (age: 27.1 +/- 1.9 yr; height: 1.82 +/- 0.06 in; mass 77.1 +/- 7.7 kg) performed an active orthostatic test during which R-R intervals were Simultaneously recorded with the HRM and the ECG recorder The two signals were synchronized and corrected before a time domain analysis, the fast Fourier transform (FFT) and a Poincare plot analysis. Bias and limits of agreement (LoA), effect size (ES), and correlation coefficients were calculated. Results: R-R intervals were significantly different in the supine and standing position between the ECG and the FIRM uncorrected and corrected signal (P < 0.05, ES = 0.000 and 0.006, respectively). The bias LoA, however, were 0.9 +/- 12 ms. HRV parameters derived front both signals in both positions were not different (P > 0.05) and well correlated (r > 0.97, P < 0.05). except root mean square of difference (RMSSD) and SDI in standing position (P < 0.05, ES = 0.052 and 0.057; r = 0.99 and 0.98, respectively). Conclusion: Narrow LoA, good correlations, and small effect sizes support the validity of the Polar S810 HRM to measure R-R intervals and make the subsequent HRV analysis in supine position. Caution must be taken in standing position for the parameters sensitive to the short-term variability (i.e., RMSSD and SDI).
引用
收藏
页码:887 / 893
页数:7
相关论文
共 23 条
  • [1] BAUGMARTER T, 1989, MEASUREMENT CONCEPTS, P45
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] Do existing measures of Poincare plot geometry reflect nonlinear features of heart rate variability?
    Brennan, M
    Palaniswami, M
    Kamen, P
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (11) : 1342 - 1347
  • [4] Camm AJ, 1996, CIRCULATION, V93, P1043
  • [5] Cohen J., 1988, STAT POWER ANAL BEHA
  • [6] Heart rate variability, trait anxiety, and perceived stress among physically fit men and women
    Dishman, RK
    Nakamura, Y
    Garcia, ME
    Thompson, RW
    Dunn, AL
    Blair, SN
    [J]. INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 2000, 37 (02) : 121 - 133
  • [7] Autonomic balance revisited: Panic anxiety and heart rate variability
    Friedman, BH
    Thayer, JF
    [J]. JOURNAL OF PSYCHOSOMATIC RESEARCH, 1998, 44 (01) : 133 - 151
  • [8] Short-term overtraining:: effects on performance, circulatory responses, and heart rate variability
    Hedelin, R
    Kenttá, G
    Wiklund, U
    Bjerle, P
    Henriksson-Larsén, K
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (08) : 1480 - 1484
  • [9] Comparison of Polar 810 s and an ambulatory ECG system for RR interval measurement during progressive exercise
    Kingsley, M
    Lewis, MJ
    Marson, RE
    [J]. INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2005, 26 (01) : 39 - 44
  • [10] Kinnunen H., 1998, Journal of Sports Sciences, V16, pS107