Optical Quality Comparison of Conventional and Hole-Visian Implantable Col lamer Lens at Different Degrees of Decentering

被引:48
作者
Perez-Vives, Cari [1 ]
Ferrer-Blasco, Teresa [1 ]
Madrid-Costa, David [1 ]
Garcia-Lazaro, Santiago [1 ]
Montes-Mico, Robert [1 ]
机构
[1] Univ Valencia, Dept Opt, Opt Res Grp, Fac Phys, E-46100 Valencia, Spain
关键词
PHAKIC INTRAOCULAR-LENS; HIGHER-ORDER ABERRATIONS; ADMINISTRATION CLINICAL-TRIAL; IN-SITU KERATOMILEUSIS; HIGH MYOPIA; COLLAMER LENS; FOLLOW-UP; VISUAL PERFORMANCE; CONTACT-LENS; IOL ICL;
D O I
10.1016/j.ajo.2013.01.030
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the optical quality of implantable Collamer lens (ICL) with and without central hole (Hole ICL and conventional ICL) at different degrees of decentering. DESIGN: Experimental laboratory investigation. METHODS: Wavefront aberrations of the -3, -6, and -12 diopter (D) V4b and -3, -6, and -12 D V4c ICLs were measured in 3 conditions centered and decentered 0.3 and 0.6 mm-at 3-mm and 4.5-mm pupils. The root mean square of total higher order aberrations, trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration were evaluated. In addition, point spread function and simulated retinal images of ICLs were calculated from the wavefront aberrations for each ICL and all conditions of decentering at 4.5-mm pupil. RESULTS: No statistically significant differences in any Zernike coefficient terms evaluated were found between conventional and Hole ICLs for any ICL powers and pupils evaluated (P > .05). We could not appreciate differences in the point spread function images and in simulated retinal images. Regarding the effect of the ICL decentration, coma aberration increased significantly with ICL decentration (P < .05), although these differences were not visible in the point spread function images and simulated retinal images. The ICL decentration was affected in the same manner on the conventional and Hole ICLs. CONCLUSIONS: The outcomes showed good and comparable optical quality of the conventional and Hole ICLs for all ICL powers evaluated. Despite that coma aberration increased with ICL decentering, these values were clinically negligible and did not have a significant effect on the simulated visual performance. (C) 2013 by Elsevier Inc. All rights reserved.
引用
收藏
页码:69 / 76
页数:8
相关论文
共 30 条
[1]   Collagen copolymer toric posterior chamber phakic intraocular lenses to correct high myopic astigmatism [J].
Alfonso, Jose F. ;
Baamonde, Begona ;
Madrid-Costa, David ;
Fernandes, Paulo ;
Jorge, Jorge ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (08) :1349-1357
[2]   Collagen copolymer toric posterior chamber phakic intraocular lens for myopic astigmatism One-year follow-up [J].
Alfonso, Jose F. ;
Fernandez-Vega, Luis ;
Fernandes, Paulo ;
Gonzalez-Meijome, Jose M. ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (04) :568-576
[3]  
Davidorf JM, 1998, J REFRACT SURG, V14, P306
[4]   Implantable Collamer Posterior Chamber Intraocular Lenses: A Review of Potential Complications [J].
Fernandes, Paulo ;
Gonzalez-Meijome, Jose M. ;
Madrid-Costa, David ;
Ferrer-Blasco, Teresa ;
Jorge, Jorge ;
Montes-Mico, Robert .
JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (10) :765-776
[5]   Changes in the crystalline lens resulting from insertion of a phakic IOL (ICL) into the porcine eye [J].
Fujisawa, Kunitoshi ;
Shimizu, Kimiya ;
Uga, Shigekazu ;
Suzuki, Masanobu ;
Nagano, Koichi ;
Murakami, Yuuki ;
Goseki, Hiroko .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 245 (01) :114-122
[6]   Implantable contact lens for moderate to high myopia - Relationship of vaulting to cataract formation [J].
Gonvers, M ;
Bornet, C ;
Othenin-Girard, P .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (05) :918-924
[7]   Effect of rotation and translation on the expected benefit of an ideal method to correct the eye's higher-order aberrations [J].
Guirao, A ;
Williams, DR ;
Cox, IG .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2001, 18 (05) :1003-1015
[8]   Visual Performance after Implantable Collamer Lens Implantation and Wavefront-Guided Laser In Situ Keratomileusis for High Myopia [J].
Igarashi, Akihito ;
Kamiya, Kazutaka ;
Shimizu, Kimiya ;
Komatsu, Mari .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 148 (01) :164-170
[9]   Phase-shifting: schlieren high-resolution quantitative schlieren that uses the phase-shifting technique principle [J].
Joannes, L ;
Dubois, F ;
Legros, JC .
APPLIED OPTICS, 2003, 42 (25) :5046-5053
[10]   The reproducibility of a new power mapping instrument based on the phase shifting schlieren method for the measurement of spherical and toric contact lenses [J].
Joannes, Luc ;
Hough, Tony ;
Hutsebaut, Xavier ;
Dubois, Xavier ;
Ligot, Renaud ;
Saoul, Bruno ;
Van Donink, Philip ;
De Coninck, Kris .
CONTACT LENS & ANTERIOR EYE, 2010, 33 (01) :3-8