MR Elastography of the Liver: Defining Thresholds for Detecting Viscoelastic Changes

被引:31
作者
Bohte, Anneloes E. [1 ]
Garteiser, Philippe [3 ]
De Niet, Annikki [2 ]
Groot, Paul F. C. [1 ]
Sinkus, Ralph [3 ]
Stoker, Jaap [1 ]
Nederveen, Aart J. [1 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Radiol, NL-1105 AZ Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Gastroenterol & Hepatol, NL-1105 AZ Amsterdam, Netherlands
[3] Univ Paris Diderot, Dept Radiol, Univ Hosp Paris Nord Val de Seine, Sorbonne Paris Cite,INSERM,UMR 773, Clichy, France
关键词
MAGNETIC-RESONANCE ELASTOGRAPHY; CHRONIC HEPATITIS-C; NONINVASIVE ASSESSMENT; BREAST-LESIONS; FIBROSIS; REPEATABILITY; STIFFNESS; STATE;
D O I
10.1148/radiol.13122669
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To define thresholds for detecting significant change in liver viscoelasticity with magnetic resonance (MR) elastography, both for whole-liver measurements and for voxel-wise measurements in relation to spatial resolution. Materials and Methods: This prospective study was approved by the institutional review board, and all participants provided written informed consent. Thirty participants (16 volunteers and 14 patients with hepatitis B or C; 18 men; median age, 30.4 years; age range, 18.9-58.6 years) underwent imaging twice while in the same position (intraimage reproducibility), after repositioning (within-day reproducibility), and 1-4 weeks later (between-weeks reproducibility). MR elastography parameters comprised elasticity, viscosity, attenuation parameter alpha, and propagation parameter beta. Bland-Altman analysis was used to calculate repeatability indexes for each parameter. Analyses were performed in a region-of-interest and a voxel-by-voxel level. Voxel-wise results were calculated in relation to spatial resolution by applying Gaussian filtering to establish the optimal trade-off point between resolution and reproducibility. Results: For elasticity, alpha, and beta, within-day and between-weeks results were significantly lower than intraimage results (P <= .018 for all). Within-day and between-weeks results did not differ significantly. Over-time changes of more than 22.2% for elasticity, 26.3% for viscosity, 26.8% for alpha, and 10.1% for beta represented thresholds for significant change. The optimal trade-off between spatial resolution and reproducibility was found at a filter size of 8-mm full width at half maximum (FWHM) for elasticity and propagation parameter alpha and at 16-mm FWHM for viscosity and attenuation parameter alpha. Conclusion: Repositioning causes a significant decrease in the reproducibility of MR elastography. The propagation parameter beta is the most reliable parameter, with an over-time threshold for significant change of 10.1% and the ability to reproduce viscoelasticity up to a resolution of 8-mm FWHM. (C)RSNA, 2013
引用
收藏
页码:768 / 776
页数:9
相关论文
共 24 条
[1]   An algorithm for the grading of activity in chronic hepatitis C [J].
Bedossa, P ;
Poynard, T .
HEPATOLOGY, 1996, 24 (02) :289-293
[2]   Sampling variability of liver fibrosis in chronic hepatitis C [J].
Bedossa, P ;
Dargère, D ;
Paradis, V .
HEPATOLOGY, 2003, 38 (06) :1449-1457
[3]   Measurement error [J].
Bland, JM ;
Altman, DG .
BRITISH MEDICAL JOURNAL, 1996, 312 (7047) :1654-1654
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   MR Imaging of Liver Fibrosis: Current State of the Art [J].
Faria, Silvana C. ;
Ganesan, Karthik ;
Mwangi, Irene ;
Shiehmorteza, Masoud ;
Viamonte, Barbara ;
Mazhar, Sameer ;
Peterson, Michael ;
Kono, Yuko ;
Santillan, Cynthia ;
Casola, Giovanna ;
Sirlin, Claude B. .
RADIOGRAPHICS, 2009, 29 (06) :1615-1636
[6]  
Garteiser P, 2012, P 20 M INT SOC MAGN, P3423
[7]   MR elastography of liver tumours: value of viscoelastic properties for tumour characterisation [J].
Garteiser, Philippe ;
Doblas, Sabrina ;
Daire, Jean-Luc ;
Wagner, Mathilde ;
Leitao, Helena ;
Vilgrain, Valerie ;
Sinkus, Ralph ;
Van Beers, Bernard E. .
EUROPEAN RADIOLOGY, 2012, 22 (10) :2169-2177
[8]  
GraphPad software, BLAND ALTM PLOT
[9]   Effects of Postprandial State and Mesenteric Blood Flow on the Repeatability of MR Elastography in Asymptomatic Subjects [J].
Hines, Catherine D. G. ;
Lindstrom, Mary J. ;
Varma, Adarsh K. ;
Reeder, Scott B. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (01) :239-244
[10]   Repeatability of Magnetic Resonance Elastography for Quantification of Hepatic Stiffness [J].
Hines, Catherine D. G. ;
Bley, Thorsten A. ;
Lindstrom, Mary J. ;
Reeder, Scott B. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (03) :725-731