Diagnostic Implications of Soluble Triggering Receptor Expressed on Myeloid Cells-1 in BAL Fluid of Patients With Pulmonary Infiltrates in the ICU
被引:93
作者:
Anand, Nitin J.
论文数: 0引用数: 0
h-index: 0
机构:
Washington Univ, Sch Med, Div Pulm & Crit Care Med, St Louis, MO 63110 USAWashington Univ, Sch Med, Div Pulm & Crit Care Med, St Louis, MO 63110 USA
Anand, Nitin J.
[1
]
Zuick, Scott
论文数: 0引用数: 0
h-index: 0
机构:
Washington Univ, Sch Med, Div Pulm & Crit Care Med, St Louis, MO 63110 USAWashington Univ, Sch Med, Div Pulm & Crit Care Med, St Louis, MO 63110 USA
Zuick, Scott
[1
]
Klesney-Tait, Julia
论文数: 0引用数: 0
h-index: 0
机构:
Univ Iowa Hosp & Clin, Div Pulm Occupat Med & Crit Care, Iowa City, IA 52242 USAWashington Univ, Sch Med, Div Pulm & Crit Care Med, St Louis, MO 63110 USA
Klesney-Tait, Julia
[2
]
Kollef, Marin H.
论文数: 0引用数: 0
h-index: 0
机构:
Washington Univ, Sch Med, Div Pulm & Crit Care Med, St Louis, MO 63110 USAWashington Univ, Sch Med, Div Pulm & Crit Care Med, St Louis, MO 63110 USA
Kollef, Marin H.
[1
]
机构:
[1] Washington Univ, Sch Med, Div Pulm & Crit Care Med, St Louis, MO 63110 USA
[2] Univ Iowa Hosp & Clin, Div Pulm Occupat Med & Crit Care, Iowa City, IA 52242 USA
Objective: Prospective single-center study to determine whether the presence of soluble-triggering receptor expressed on myeloid cells-1 (sTREM-1) has diagnostic utility in patients with pulmonary infiltrates receiving mechanical ventilation and undergoing BAL. Design: Prospective cohort study. Setting: Barnes-Jewish Hospital, a 1,200-bed urban teaching hospital. Patients: Adult patients with acute respiratory failure undergoing BAL for pulmonary infiltrates. Interventions: BAL fluid measurement of sTREM-1 concentration using a Quantikine Human TREM-1 Immunoassay (R&D Systems; Minneapolis, MN). Measurements and main results: A total of 105 consecutive patients receiving mechanical ventilation and undergoing BAL were enrolled. Of those, 19 patients (18.1%) met definite microbiologic criteria for bacterial or fungal ventilator-associated pneumonia (VAP). Though the mean sTREM-1 concentration was greater in patients with definite VAP (n = 19; 171.9 +/- 158.7 pg/mL) than in patients with definite absence of VAP (n = 21; 96.7 +/- 76.2 pg/mL), this difference was not statistically significant (p = 0.06). A cutoff value for sTREM-1 > 200 pg/mL yielded a diagnostic sensitivity of 42.1% and a specificity of 75.6% for definite VAP. Patients with alveolar hemorrhage had the greatest values for sTREM-1 concentration (n = 9; 555 440 pg/mL). Receiver operating curve analysis and multivariate logistic regression analysis demonstrated that measurement of sTREM-1 was inferior to clinical parameters for the diagnosis of VAP. Conclusions: Measurement of sTREM-1 in BAL fluid appears to have minimal diagnostic value for VAP.
机构:
Washington Univ, Sch Med, Div Pulm & Crit Care Med, St Louis, MO 63110 USAWashington Univ, Sch Med, Div Pulm & Crit Care Med, St Louis, MO 63110 USA
Kollef, MH
Kollef, KE
论文数: 0引用数: 0
h-index: 0
机构:
Washington Univ, Sch Med, Div Pulm & Crit Care Med, St Louis, MO 63110 USAWashington Univ, Sch Med, Div Pulm & Crit Care Med, St Louis, MO 63110 USA
机构:
Washington Univ, Sch Med, Div Pulm & Crit Care Med, St Louis, MO 63110 USAWashington Univ, Sch Med, Div Pulm & Crit Care Med, St Louis, MO 63110 USA
Kollef, MH
Kollef, KE
论文数: 0引用数: 0
h-index: 0
机构:
Washington Univ, Sch Med, Div Pulm & Crit Care Med, St Louis, MO 63110 USAWashington Univ, Sch Med, Div Pulm & Crit Care Med, St Louis, MO 63110 USA