Recombinant Peptidomimetic-Nano Luciferase Tracers for Sensitive Single-Step Immunodetection of Small Molecules

被引:28
作者
Ding, Yuan [1 ,2 ]
Hua, Xiude [1 ,2 ]
Chen, He [1 ,2 ]
Liu, Fengquan [1 ,2 ,3 ]
Gonzalez-Sapien, Gualberto [4 ]
Wang, Minghua [1 ,2 ]
机构
[1] Nanjing Agr Univ, Coll Plant Protect, Nanjing 210095, Jiangsu, Peoples R China
[2] State & Local Joint Engn Res Ctr Green Pesticide, Nanjing 210095, Jiangsu, Peoples R China
[3] Jiangsu Acad Agr Sci, Inst Plant Protect, Nanjing 210014, Jiangsu, Peoples R China
[4] Univ Republica, Inst Higiene, Fac Quim, Catedra Inmunol, Montevideo 11600, Uruguay
基金
中国国家自然科学基金;
关键词
DISPLAY PEPTIDE LIBRARIES; ANTI-IMMUNOCOMPLEX ASSAY; NONCOMPETITIVE IMMUNOASSAY; SMALL ANALYTES; PHAGE; NANOPARTICLES;
D O I
10.1021/acs.analchem.7b04601
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Phage borne peptides isolated from phage libraries have proven to be valuable reagents for the development of small-molecule immunoassays. However, the large size, low diffusion rate, and biological nature of the phage particles create some limitations to their use and require secondary reagents for its detection. In this work, we explore the use of the Nano luciferase (NanoLuc) as a fusion partner to generate recombinant tracers for immunoassay development. The imidaclothiz peptidomimetic C2-15 that specifically binds to the anti-imidaclothiz monoclonal antibody (mAb) 1E(7) was fused to NanoLuc, both at the N terminus (C2-15-NanoLuc) and C terminus (NanoLuc-C2-15). NanoLuc-C2-15 showed better performance than C2-15-NanoLuc and was adopted to develop a bioluminescent enzyme immunoassay (BLEIA) and a bioluminescence lateral flow immunoassay (BLLFIA) for imidaclothiz. The luminescence signal of NanoLuc-C2-15 rapidly reaches high intensity with slow attenuation, which enabled one to capture the BLLFIA readout by using a smartphone without an external light source. The IC50 of the BLEIA and BLLFIA were 3.3 +/- 0.2 and 6.4 +/- 0.4 ng mL(-1), respectively. Both immunoassays exhibited good accuracy for the detection of imidaclothiz in environmental and agricultural samples.
引用
收藏
页码:2230 / 2237
页数:8
相关论文
共 26 条
  • [1] Specific Noncompetitive Immunoassay for HT-2 Mycotoxin Detection
    Arola, Henri O.
    Tullila, Antti
    Kiljunen, Harri
    Campbell, Katrina
    Siitari, Harri
    Nevanen, Tarja K.
    [J]. ANALYTICAL CHEMISTRY, 2016, 88 (04) : 2446 - 2452
  • [2] Analyte peptidomimetics selected from phage display peptide libraries:: a systematic strategy for the development of environmental Immunoassays
    Cardozo, S
    González-Techera, A
    Last, JA
    Hammock, BD
    Kramer, K
    González-Sapienza, GG
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (11) : 4234 - 4241
  • [3] Recombinant Streptavidin Nanopeptamer Anti-Immunocomplex Assay for Noncompetitive Detection of Small Analytes
    Carlomagno, Mariana
    Lassabe, Gabriel
    Rossotti, Martin
    Gonzalez-Techera, Andres
    Vanrell, Lucia
    Gonzalez-Sapienza, Gualberto
    [J]. ANALYTICAL CHEMISTRY, 2014, 86 (20) : 10467 - 10473
  • [4] Development of a phage chemiluminescent enzyme immunoassay with high sensitivity for the determination of imidaclothiz in agricultural and environmental samples
    Ding, Yuan
    Hua, Xiude
    Sun, Nana
    Yang, Jiachuan
    Deng, Jiaqi
    Shi, Haiyan
    Wang, Minghua
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2017, 609 : 854 - 860
  • [5] Development of a Sensitive Indirect Competitive Enzyme-Linked Immunosorbent Assay (ic-ELISA) Based on the Monoclonal Antibody for the Detection of the Imidaclothiz Residue
    Fang, Song
    Zhang, Bin
    Ren, Ke-wei
    Cao, Meng-meng
    Shi, Hai-yan
    Wang, Ming-hua
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2011, 59 (05) : 1594 - 1597
  • [6] High-throughput method for ranking the affinity of peptide ligands selected from phage display libraries
    Gonzalez-Techera, A.
    Umpierrez-Failache, M.
    Cardozo, S.
    Obal, G.
    Pritsch, O.
    Last, J. A.
    Gee, S. J.
    Hammock, B. D.
    Gonzalez-Sapienza, G.
    [J]. BIOCONJUGATE CHEMISTRY, 2008, 19 (05) : 993 - 1000
  • [7] Polyclonal antibody-based noncompetitive immunoassay for small analytes developed with short peptide loops isolated from phage libraries
    Gonzalez-Techera, A.
    Kim, H. J.
    Gee, S. J.
    Last, J. A.
    Hammock, B. D.
    Gonzalez-Sapienza, G.
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (23) : 9191 - 9196
  • [8] Peptide-Enhanced Selective Surface Deposition of Polymer-Based Fragrance Delivery Systems
    Guenay, Kemal Arda
    Benczedi, Daniel
    Herrmann, Andreas
    Klok, Harm-Anton
    [J]. ADVANCED FUNCTIONAL MATERIALS, 2017, 27 (02)
  • [9] Engineered Luciferase Reporter from a Deep Sea Shrimp Utilizing a Novel Imidazopyrazinone Substrate
    Hall, Mary P.
    Unch, James
    Binkowski, Brock F.
    Valley, Michael P.
    Butler, Braeden L.
    Wood, Monika G.
    Otto, Paul
    Zimmerman, Kristopher
    Vidugiris, Gediminas
    Machleidt, Thomas
    Robers, Matthew B.
    Benink, Helene A.
    Eggers, Christopher T.
    Slater, Michael R.
    Meisenheimer, Poncho L.
    Klaubert, Dieter H.
    Fan, Frank
    Encell, Lance P.
    Wood, Keith V.
    [J]. ACS CHEMICAL BIOLOGY, 2012, 7 (11) : 1848 - 1857
  • [10] Competitive and noncompetitive phage immunoassays for the determination of benzothiostrobin
    Hua, Xiude
    Zhou, Liangliang
    Feng, Lu
    Ding, Yuan
    Shi, Haiyan
    Wang, Limin
    Gee, Shirley J.
    Hammock, Bruce D.
    Wang, Minghua
    [J]. ANALYTICA CHIMICA ACTA, 2015, 890 : 150 - 156