The crosswind effects on the start-up process of natural draft dry cooling towers in dispatchable power plants

被引:37
作者
Dong, Peixin [1 ]
Li, Xiaoxiao [2 ]
Hooman, Kamel [1 ]
Sun, Yubiao [1 ]
Li, Jishun [3 ]
Guan, Zhiqiang [1 ]
Gurgenci, Hal [1 ]
机构
[1] Univ Queensland, Sch Mech & Min Engn, Brisbane, Qld 4067, Australia
[2] Chongqing Univ, Coll Power Engn, Minist Educ, Key Lab Low Grade Energy Utilizat Technol & Syst, Chongqing 400030, Peoples R China
[3] Henan Univ Sci & Technol, Sch Mechatron Engn, Luoyang 471003, Henan, Peoples R China
关键词
Natural draft dry cooling towers (NDDCTs); Theoretical predictions; Numerical analysis; Crosswind; Dispatchable power plants; WINDBREAK WALL; PERFORMANCE; WIND; EFFICIENCY; SYSTEMS;
D O I
10.1016/j.ijheatmasstransfer.2019.02.039
中图分类号
O414.1 [热力学];
学科分类号
摘要
To investigate the suitability of natural draft dry cooling towers (NDDCTs) for PV/CST hybrid power plants in practice, the crosswind effects on transient start-up of NDDCTs are analyzed first using a simplified theoretical approximation and then numerical computations. The study covers crosswind speeds from 1 to 15 m/s. Simplified model identifies two distinct flow patterns that correspond to two ends of the wind speed range. The intersection of asymptotes technique is adopted to find when the flow switches from one pattern to the other. The switching wind speed also corresponds to the longest start-up time. Results of numerical analysis agree with these observations and provide more detailed insights. It is found that natural draft dominates the air flow at wind speeds below the cross-over and crosswind is dominant at higher wind speeds. The cold air incursion at the top plays an increasingly important role as the wind speed is increased and finally shuts off the tower top completely preventing any outflow from the to,p. The uniformity index is introduced as a single parameter to describe the flow distribution characteristics. The flow field is uniform if only a single mechanism becomes dominant: either natural draft or forced convection caused by crosswind. The start-up time is shorter when the flow is uniform and the longest when the flow field is least uniform. All results have been validated against experimental data collected on the University of Queensland natural draft dry cooling tower Gatton test rig. This research provides a practical perception for the crosswind effects on the transient start-up of NDDCT for dispatchable thermal power plants, guaranteeing a better cooperation between PV and CST part in PV/CST hybrid power generation system. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:950 / 961
页数:12
相关论文
共 32 条
  • [1] [Anonymous], 2011, GUID AFU REL 14 0
  • [2] Grid flexibility and storage required to achieve very high penetration of variable renewable electricity
    Denholm, Paul
    Hand, Maureen
    [J]. ENERGY POLICY, 2011, 39 (03) : 1817 - 1830
  • [3] Numerical investigation of the influence of local effects on the transient start-up process of natural draft dry cooling towers in dispatchable power plants
    Dong, Peixin
    Li, Xiaoxiao
    Sun, Yubiao
    Hooman, Kamel
    Guan, Zhiqiang
    Dai, Yuchen
    Gurgenci, Hal
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 133 : 166 - 178
  • [4] The transient start-up process of natural draft dry cooling towers in dispatchable thermal power plants
    Dong, Peixin
    Li, Xiaoxiao
    Guan, Zhiqiang
    Gurgenci, Hal
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 123 : 201 - 212
  • [5] DUPREEZ AF, 1995, HEAT TRANSFER ENG, V16, P42, DOI 10.1080/01457639508939852
  • [6] EFFECT OF WIND ON PERFORMANCE OF A DRY-COOLING TOWER
    DUPREEZ, AF
    KROGER, DG
    [J]. HEAT RECOVERY SYSTEMS & CHP, 1993, 13 (02): : 139 - 146
  • [7] Understanding Bernoulli's principle through simulations
    Faulkner, Brian E.
    Ytreberg, F. Marty
    [J]. AMERICAN JOURNAL OF PHYSICS, 2011, 79 (02) : 214 - 216
  • [8] Experimental study regarding the evolution of temperature profiles inside wet cooling tower under crosswind conditions
    Gao, Ming
    Sun, Feng-zhong
    Turan, A.
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2014, 86 : 284 - 291
  • [9] Artificial neural network model research on effects of cross-wind to performance parameters of wet cooling tower based on level Froude number
    Gao, Ming
    Shi, Yue-tao
    Wang, Ni-ni
    Zhao, Yuan-bin
    Sun, Feng-zhong
    [J]. APPLIED THERMAL ENGINEERING, 2013, 51 (1-2) : 1226 - 1234
  • [10] Implicit computation of three-dimensional compressible Navier-Stokes equations using kappa-epsilon closure
    Gerolymos, GA
    Vallet, I