Electrocatalytic determination of captopril using a modified carbon nanotube paste electrode: Application to determination of captopril in pharmaceutical and biological samples

被引:87
作者
Beitollahi, Hadi [1 ]
Taher, Mohammad Ali [2 ]
Ahmadipour, Malihe [2 ,3 ]
Hosseinzadeh, Rahman [4 ]
机构
[1] Grad Univ Adv Technol, Dept Environm, Inst Sci & High Technol & Environm Sci, Kerman, Iran
[2] Shahid Bahonar Univ Kerman, Dept Chem, Kerman, Iran
[3] Shahid Bahonar Univ Kerman, Young Researchers Soc, Kerman, Iran
[4] Univ Mazandaran, Dept Organ Chem, Fac Chem, Babol Sar, Iran
关键词
Captopril; Electrochemical sensor; Voltammetry; Carbon nanotube paste electrodes; SENSITIVE VOLTAMMETRIC SENSOR; URIC-ACID; ELECTROCHEMICAL SENSOR; ASCORBIC-ACID; SELECTIVE DETERMINATION; HUMAN PLASMA; 2,7-BIS(FERROCENYL ETHYL)FLUOREN-9-ONE; POTENTIOMETRIC SENSOR; LIQUID-CHROMATOGRAPHY; MASS-SPECTROMETRY;
D O I
10.1016/j.measurement.2013.10.001
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A carbon paste electrode modified with carbon nanotube and benzoylferrocene (BF) was fabricated. The electrochemical study of the modified electrode, as well as its efficiency for electrocatalytic oxidation of captopril (CAP), was described. The electrode was employed to study the electrocatalytic oxidation of CAP, using cyclic voltammetry (CV), chronoamperometry (CHA) and square wave voltammetry (SWV) as diagnostic techniques. It has been found that the oxidation of CAP at the surface of modified electrode occurs at a potential of about 85 mV less positive than that of an unmodified CPE. SWV exhibits a linear dynamic range from 1.0 x 10(-7) to 3.5 x 10(-4) M and a detection limit of 3.0 x 10(-8) M for CAP. Finally the modified electrode was used for determination of CAP in CAP tablet and urine sample. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:770 / 776
页数:7
相关论文
共 82 条
[61]   Square-wave voltammetric (SWV) determination of Captopril in reconstituted serum and pharmaceutical formulations [J].
Parham, H ;
Zargar, B .
TALANTA, 2005, 65 (03) :776-780
[62]   Development and validation of a capillary electrophoresis method with laser-induced fluorescence detection for the determination of captopril in human urine and pharmaceutical preparations [J].
Perez-Ruiz, Tomas ;
Martinez-Lozano, Carmen ;
Galera, Raquel .
ELECTROPHORESIS, 2006, 27 (12) :2310-2316
[63]   Sequential injection analysis of captopril based on colorimetric and potentiometric detection [J].
Pimenta, AM ;
Araújo, AN ;
Montenegro, MCBSM .
ANALYTICA CHIMICA ACTA, 2001, 438 (1-2) :31-38
[64]   Sensitive determination of captopril by time-resolved chemiluminescence using the stopped-flow analysis based on potassium permanganate oxidation [J].
Pulgarín, JAM ;
Bermejo, LFG ;
López, PF .
ANALYTICA CHIMICA ACTA, 2005, 546 (01) :60-67
[65]   Electrocatalytic determination of ascorbic acid at the surface of 2,7-bis(ferrocenyl ethyl)fluoren-9-one modified carbon paste electrode [J].
Raoof, J. B. ;
Ojani, R. ;
Beitollahi, Hadi ;
Hossienzadeh, R. .
ELECTROANALYSIS, 2006, 18 (12) :1193-1201
[66]   Voltammetric behavior of multi-walled carbon nanotubes modified electrode-hexacyanoferrate(II) electrocatalyst system as a sensor for determination of captopril [J].
Rezaei, B. ;
Damiri, S. .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 134 (01) :324-331
[67]   Determination of captopril in human plasma, using solid phase extraction and high-performance liquid chromatography, coupled to mass spectrometry:: Application to bioequivalence study [J].
Rezende, Kennia R. ;
Mundim, Iram M. ;
Teixeira, Leonardo S. ;
Souza, Weidson C. ;
Ramos, Douglas R. ;
Cardoso, Claudio R. F. ;
Souza, Inacia C. ;
Gratao, Mario Z. ;
Bellorio, Karini B. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 850 (1-2) :59-67
[68]   Nile Blue-hexacyanoferrate carbon paste modified electrode as an amperometric sensor for determination of hydrazine [J].
Sabzi, Reza Emamali ;
Minaie, Elnaz ;
Farhadi, Khalil ;
Golzan, Mir Maqsoud .
TURKISH JOURNAL OF CHEMISTRY, 2010, 34 (06) :901-910
[69]   A selective and rapid method for the quantification of captopril in human plasma using liquid chromatography/selected reaction monitoring mass spectrometry [J].
Salem, II ;
Abu Saif, W ;
Jmeian, Y ;
Al Tamimi, JI .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 37 (05) :1073-1080
[70]   High sensitivity amperometric and voltammetric determination of persulfate with neutral red/nickel oxide nanowires modified carbon paste electrodes [J].
Savari, Z. ;
Soltanian, S. ;
Noorbakhsh, A. ;
Salimi, A. ;
Najafi, M. ;
Servati, P. .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 176 :335-343