Technique for bone volume measurement from human femur head samples by classification of micro-CT image histograms

被引:20
作者
Marinozzi, Franco [1 ]
Bini, Fabiano [1 ]
Marinozzi, Andrea [2 ]
Zuppante, Francesca [1 ]
De Paolis, Annalisa [1 ]
Pecci, Raffaella [3 ]
Bedini, Rossella [3 ]
机构
[1] Sapienza Univ Roma, Dipartimento Ingn Meccan & Aerospaziale, I-00184 Rome, Italy
[2] Policlinico Univ Campus Biomed, Rome, Italy
[3] Ist Super Sanita, Dipartimento Tecnol & Salute, I-00161 Rome, Italy
来源
ANNALI DELL ISTITUTO SUPERIORE DI SANITA | 2013年 / 49卷 / 03期
关键词
microtomography; osteoarthritis; osteoporosis; bone morphometry; image processing; TRABECULAR BONE; CANCELLOUS BONE; RESOLUTION; OSTEOPOROSIS;
D O I
10.4415/ANN_13_03_11
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Introduction. Micro-CT analysis is a powerful technique for a non-invasive evaluation of the morphometric parameters of trabecular bone samples. This elaboration requires a previous binarization of the images. A problem which arises from the binarization process is the partial volume artifact. Voxels at the external surface of the sample can contain both bone and air so thresholding operates an incorrect estimation of volume occupied by the two materials. Aim. The aim of this study is the extraction of bone volumetric information directly from the image histograms, by fitting them with a suitable set of functions. Methods. Nineteen trabecular bone samples were extracted from femoral heads of eight patients subject to a hip arthroplasty surgery. Trabecular bone samples were acquired using micro-CT Scanner. Hystograms of the acquired images were computed and fitted by Gaussian-like functions accounting for: a) gray levels produced by the bone x-ray absorption, b) the portions of the image occupied by air and c) voxels that contain a mixture of bone and air. This latter contribution can be considered such as an estimation of the partial volume effect. Results. The comparison of the proposed technique to the bone volumes measured by a reference instrument such as by a helium pycnometer show the method as a good way for an accurate bone volume calculation of trabecular bone samples.
引用
收藏
页码:300 / 305
页数:6
相关论文
共 26 条
  • [1] Bedini R, 2010, 1015 ISTISAN
  • [2] Accuracy of cancellous bone volume fraction measured by micro-CT scanning
    Ding, M
    Odgaard, A
    Hvid, I
    [J]. JOURNAL OF BIOMECHANICS, 1999, 32 (03) : 323 - 326
  • [3] Changes in the three-dimensional microstructure of human tibial cancellous bone in early osteoarthritis
    Ding, M
    Odgaard, A
    Hvid, I
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (06): : 906 - 912
  • [4] Quantitative CT in the measurement of bone quantity and bone quality for assessing osteoporosis
    Dougherty, G
    [J]. MEDICAL ENGINEERING & PHYSICS, 1996, 18 (07) : 557 - 568
  • [5] Femoral trabecular bone of osteoarthritic and normal subjects in an age and sex matched group
    Fazzalari, NL
    Parkinson, IH
    [J]. OSTEOARTHRITIS AND CARTILAGE, 1998, 6 (06) : 377 - 382
  • [6] PRACTICAL CONE-BEAM ALGORITHM
    FELDKAMP, LA
    DAVIS, LC
    KRESS, JW
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06): : 612 - 619
  • [7] Direct three-dimensional morphometric analysis of human cancellous bone:: Microstructural data from spine, femur, iliac crest, and calcaneus
    Hildebrand, T
    Laib, A
    Müller, R
    Dequeker, J
    Rüegsegger, P
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 1999, 14 (07) : 1167 - 1174
  • [8] Assessment of bone ingrowth into porous biomaterials using MICRO-CT
    Jones, Anthony C.
    Arns, Christoph H.
    Sheppard, Adrian P.
    Hutmacher, Dietmar W.
    Milthorpe, Bruce K.
    Knackstedt, Mark A.
    [J]. BIOMATERIALS, 2007, 28 (15) : 2491 - 2504
  • [9] Effects of thresholding techniques on μCT-Based finite element models of trabecular bone
    Kim, Chi Hyun
    Zhang, Henry
    Mikhail, George
    Von Stechow, Dietrich
    Mueller, Ralph
    Kim, Han Sung
    Guo, X. Edward
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2007, 129 (04): : 481 - 486
  • [10] Impact of spatial resolution on the prediction of trabecular architecture parameters
    Kothari, M
    Keaveny, TM
    Lin, JC
    Newitt, DC
    Genant, HK
    Majumdar, S
    [J]. BONE, 1998, 22 (05) : 437 - 443