Cardiac Index Assessment by the Pressure Recording Analytic Method in Critically Ill Unstable Patients After Cardiac Surgery

被引:20
作者
Barille, Luigi [1 ]
Landoni, Giovanni [1 ]
Pieri, Marina [1 ]
Ruggeri, Laura [1 ]
Maj, Giulia [1 ]
Nigro Neto, Caetano [2 ,3 ]
Pasin, Laura [2 ,3 ]
Cabrini, Luca [2 ,3 ]
Zangrillo, Alberto [1 ]
机构
[1] Ist Sci San Raffaele, Anesthesia & Intens Care Dept, I-20132 Milan, Italy
[2] Dante Pazzanese Inst Cardiol, Anaesthesia & Intens Care Dept, Sao Paulo, Brazil
[3] Fed Univ Sao Paulo UNIFESP, Sao Paulo, Brazil
关键词
pressure recording analytic method; PRAM; pulmonary artery catheter; cardiac index; cardiac surgery; high-risk patients; unstable patients; atrial fibrillation; anesthesia; intensive care; thermodilution; RISK SURGICAL-PATIENTS; PULSE CONTOUR METHOD; ATRIAL-FIBRILLATION; ARTERIAL-PRESSURE; BLOOD-FLOW; WAVE-FORM; OUTPUT; METAANALYSIS; AGREEMENT; PRECISION;
D O I
10.1053/j.jvca.2013.02.016
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: The authors measured cardiac index in unstable patients after cardiac surgery with the Pressure Recording Analytic Method (PRAM) and compared it with the reference method of thermodilution (ThD) with the pulmonary artery catheter; using the hypothesis that there were no significant differences between the 2 methods. Design: A prospective study. Setting: Cardiac surgery intensive care unit in a teaching hospital. Participants: Ninety-four measurements from 59 patients with ongoing high doses of inotropic drugs and/or an intra-aortic balloon pump for low-cardiac-output syndrome after cardiac surgery were studied. Interventions: The pulmonary artery catheter and the radial or femoral arterial catheter for measuring blood pressure were already in place for standard hemodynamic monitoring. Measurements and Main Results: The mean of the total Cl measurements was 2.94 +/- 0.67 L/min/m(2) with PRAM and 2.95 +/- 0.63 L/min/m(2) with ThD, with no significant difference according to the linear mixed models analysis. The PRAM and ThD techniques were similar in unstable patients without atrial fibrillation (mean bias 0.047 +/- 0.395 L/min/m(2) and a percentage error of 29%), while no agreement between PRAM and ThD was found in unstable patients with atrial fibrillation (mean bias 0.195 +/- 0.885 L/min/m(2) and a percentage error of 69%). Conclusion: Cardiac index measurements after cardiac surgery performed with PRAM and with ThD showed a good agreement in hemodynamically unstable patients given high doses of inotropes and/or an IABP in patients in sinus rhythm, but not in those with atrial fibrillation. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:1108 / 1113
页数:6
相关论文
共 25 条
[1]   Continuous hemodynamic monitoring during laparoscopic gastric bypass in superobese patients by pressure recording analytical method [J].
Balderi, Tania ;
Forfori, Francesco ;
Marra, Valeria ;
Di Salvo, Claudio ;
Dorigo, Massimo ;
Anselmino, Marco ;
Romano, Salvatore Mario ;
Giunta, Francesco .
OBESITY SURGERY, 2008, 18 (08) :1007-1014
[2]   Pressure pulse contour-derived stroke volume and cardiac output in the morbidly obese patient [J].
Bernstein, Donald P. .
OBESITY SURGERY, 2008, 18 (08) :1015-1021
[3]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[4]   Perioperative management and monitoring in anaesthesia [J].
Buhre, W ;
Rossaint, R .
LANCET, 2003, 362 (9398) :1839-1846
[5]   Assessment of cardiac output in children: A comparison between the pressure recording analytical method and Doppler echocardiogyaphy [J].
Calamandrei, Marco ;
Mirabile, Lorenzo ;
Muschetta, Stefania ;
Gensini, Gian Franco ;
De Simone, Luciano ;
Romano, Salvatore M. .
PEDIATRIC CRITICAL CARE MEDICINE, 2008, 9 (03) :310-312
[6]   A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques [J].
Critchley, LAH ;
Critchley, JAJH .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) :85-91
[7]   Cardiac output monitoring [J].
de Waal, Eric. E. C. ;
Wappler, Frank ;
Buhre, Wolfgang F. .
CURRENT OPINION IN ANESTHESIOLOGY, 2009, 22 (01) :71-77
[8]   Cardiac Efficiency Improvement after Slow Continuous Ultrafiltration Is Assessed by Beat-to-Beat Minimally Invasive Monitoring in Congestive Heart Failure Patients: A Preliminary Report [J].
Giglioli, Cristina ;
Landi, Daniele ;
Gensini, Gian Franco ;
Valente, Serafina ;
Cecchi, Emanuele ;
Scolletta, Sabino ;
Chiostri, Marco ;
Romano, Salvatore M. .
BLOOD PURIFICATION, 2010, 29 (01) :44-51
[9]   Cardiac output monitoring by pressure recording analytical method in cardiac surgery [J].
Giomarelli, P ;
Biagioli, B ;
Scolletta, S .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 26 (03) :515-520
[10]   A Systematic Review and Meta-Analysis on the Use of Preemptive Hemodynamic Intervention to Improve Postoperative Outcomes in Moderate and High-Risk Surgical Patients [J].
Hamilton, Mark A. ;
Cecconi, Maurizio ;
Rhodes, Andrew .
ANESTHESIA AND ANALGESIA, 2011, 112 (06) :1392-1402