Optimisation of window settings for traditional and noise-optimised virtual monoenergetic imaging in dual-energy computed tomography pulmonary angiography

被引:34
作者
D'Angelo, Tommaso [1 ,2 ]
Bucher, Andreas M. [1 ]
Lenga, Lukas [1 ]
Arendt, Christophe T. [1 ]
Peterke, Julia L. [1 ]
Caruso, Damiano [3 ]
Mazziotti, Silvio [2 ]
Blandino, Alfredo [2 ]
Ascenti, Giorgio [2 ]
Othman, Ahmed E. [4 ]
Martin, Simon S. [1 ]
Leithner, Doris [1 ]
Vogl, Thomas J. [1 ]
Wichmann, Julian L. [1 ]
机构
[1] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, Theodor Stern Kai 7, D-60590 Frankfurt, Germany
[2] G Martino Univ Hosp Messina, Dept Biomed Sci & Morphol & Funct Imaging, Via Consolare Valeria 1, I-98100 Messina, Italy
[3] La Sapienza Univ Hosp, Dept Radiol Sci Oncol & Pathol Sci, Latina, Italy
[4] Eberhard Karls Univ Tuebingen, Univ Tubingen Hosp, Dept Diagnost & Intervent Radiol, Tubingen, Germany
关键词
Dual-energy CT; Pulmonary embolism; Computed tomography pulmonary angiography; Windowwidth; Window level; CT ANGIOGRAPHY; DIAGNOSTIC-ACCURACY; INITIAL-EXPERIENCE; CONTRAST; EMBOLISM; ENHANCEMENT; QUALITY; VISUALIZATION; STANDARD; ARTERIES;
D O I
10.1007/s00330-017-5059-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To define optimal window settings for displaying virtual monoenergetic images (VMI) of dual-energy CT pulmonary angiography (DE-CTPA). Forty-five patients who underwent clinically-indicated third-generation dual-source DE-CTPA were retrospectively evaluated. Standard linearly-blended (M_0.6), 70-keV traditional VMI (M70), and 40-keV noise-optimised VMI (M40+) reconstructions were analysed. For M70 and M40+ datasets, the subjectively best window setting (width and level, B-W/L) was independently determined by two observers and subsequently related with pulmonary artery attenuation to calculate separate optimised values (O-W/L) using linear regression. Subjective evaluation of image quality (IQ) between W/L settings were assessed by two additional readers. Repeated measures of variance were performed to compare W/L settings and IQ indices between M_0.6, M70, and M40+. B-W/L and O-W/L for M70 were 460/140 and 450/140, and were 1100/380 and 1070/380 for M40+, respectively, differing from standard DE-CTPA W/L settings (450/100). Highest subjective scores were observed for M40+ regarding vascular contrast, embolism demarcation, and overall IQ (all p < 0.001). Application of O-W/L settings is beneficial to optimise subjective IQ of VMI reconstructions of DE-CTPA. A width slightly less than two times the pulmonary trunk attenuation and a level approximately of overall pulmonary vessel attenuation are recommended. aEuro cent Application of standard window settings for VMI results in inferior image perception. aEuro cent No significant differences between B-W/L and O-W/L for M70/M40+ were observed. aEuro cent O-W/L for M70 were 450/140 and were 1070/380 for M40+. aEuro cent Improved subjective IQ characteristics were observed for VMI displayed with O-W/L.
引用
收藏
页码:1393 / 1401
页数:9
相关论文
共 27 条
[1]   Comprehensive Comparison of Virtual Monoenergetic and Linearly Blended Reconstruction Techniques in Third-Generation Dual-Source Dual-Energy Computed Tomography Angiography of the Thorax and Abdomen [J].
Albrecht, Moritz H. ;
Trommer, Jesko ;
Wichmann, Julian L. ;
Scholtz, Jan-Erik ;
Martin, Simon S. ;
Lehnert, Thomas ;
Vogl, Thomas J. ;
Bodelle, Boris .
INVESTIGATIVE RADIOLOGY, 2016, 51 (09) :582-590
[2]   Advanced image-based virtual monoenergetic dual-energy CT angiography of the abdomen: optimization of kiloelectron volt settings to improve image contrast [J].
Albrecht, Moritz H. ;
Scholtz, Jan-Erik ;
Huesers, Kristina ;
Beeres, Martin ;
Bucher, Andreas M. ;
Kaup, Moritz ;
Martin, Simon S. ;
Fischer, Sebastian ;
Bodelle, Boris ;
Bauer, Ralf W. ;
Lehnert, Thomas ;
Vogl, Thomas J. ;
Wichmann, Julian L. .
EUROPEAN RADIOLOGY, 2016, 26 (06) :1863-1870
[3]   Value of monoenergetic low-kV dual energy CT datasets for improved image quality of CT pulmonary angiography [J].
Apfaltrer, Paul ;
Sudarski, Sonja ;
Schneider, David ;
Nance, John W., Jr. ;
Haubenreisser, Holger ;
Fink, Christian ;
Schoenberg, Stefan O. ;
Henzler, Thomas .
EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (02) :322-328
[4]   CT depiction of pulmonary emboli: Display window settings [J].
Bae, KT ;
Mody, GN ;
Balfe, DM ;
Bhalla, S ;
Gierada, DS ;
Gutierrez, FR ;
Menias, CO ;
Woodard, PK ;
Goo, IM ;
Hildebolt, CF .
RADIOLOGY, 2005, 236 (02) :677-684
[5]   Evaluation of different keV-settings in dual-energy CT angiography of the aorta using advanced image-based virtual monoenergetic imaging [J].
Beeres, Martin ;
Trommer, Jesko ;
Frellesen, Claudia ;
Nour-Eldin, Nour-Eldin A. ;
Scholtz, Jan E. ;
Herrmann, Eva ;
Vogl, Thomas J. ;
Wichmann, Julian L. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2016, 32 (01) :137-144
[6]  
Belohlávek J, 2013, EXP CLIN CARDIOL, V18, P129
[7]   Optimization of window settings for standard and advanced virtual monoenergetic imaging in abdominal dual-energy CT angiography [J].
Caruso, Damiano ;
Parinella, Ashley H. ;
Schoepf, U. Joseph ;
Stroebel, Maxwell H. ;
Mangold, Stefanie ;
Wichmann, Julian L. ;
Varga-Szemes, Akos ;
Ball, B. Devon, Jr. ;
De Santis, Domenico ;
Laghi, Andrea ;
De Cecco, Carlo N. .
ABDOMINAL RADIOLOGY, 2017, 42 (03) :772-780
[8]   Optimization of window settings for virtual monoenergetic imaging in dual-energy CT of the liver: A multi-reader evaluation of standard monoenergetic and advanced imaged-based monoenergetic datasets [J].
De Cecco, Carlo N. ;
Caruso, Damiano ;
Schoepf, U. Joseph ;
Wichmann, Julian L. ;
Ter Louw, Janet R. ;
Perry, Jonathan D. ;
Picard, Melissa M. ;
Schaefer, Amanda R. ;
Parker, Leland W. ;
Hardie, Andrew D. .
EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (04) :695-699
[9]   Assessment of an Advanced Image-Based Technique to Calculate Virtual Monoenergetic Computed Tomographic Images From a Dual-Energy Examination to Improve Contrast-To-Noise Ratio in Examinations Using Iodinated Contrast Media [J].
Grant, Katharine L. ;
Flohr, Thomas G. ;
Krauss, Bernhard ;
Sedlmair, Martin ;
Thomas, Christoph ;
Schmidt, Bernhard .
INVESTIGATIVE RADIOLOGY, 2014, 49 (09) :586-592
[10]   Suspected pulmonary embolism: Enhancement of pulmonary arteries at deep-inspiration CT angiography - Influence of patent foramen ovale and atrial-septal defect [J].
Henk, CB ;
Grampp, S ;
Linnau, KF ;
Thurnher, MM ;
Czerny, C ;
Herold, CJ ;
Mostbeck, GH .
RADIOLOGY, 2003, 226 (03) :749-755