The influence of different referencing methods on the accuracy of 13C value measurement of ethanol fuel by gas chromatography/combustion/isotope ratio mass spectrometry

被引:7
作者
Neves, Laura A. [1 ,2 ]
Rodrigues, Janaina M. [1 ]
Daroda, Romeu J. [1 ]
Silva, Paulo R. M. [1 ]
Ferreira, Alexandre A. [3 ]
Aranda, Donato A. G. [2 ]
Eberlin, Marcos N. [1 ,4 ]
Fasciotti, Maira [1 ,4 ]
机构
[1] Natl Inst Metrol Qual & Technol INMETRO, Div Chem Metrol, BR-25250020 Duque De Caxias, RJ, Brazil
[2] Univ Fed Rio de Janeiro, Sch Chem, Lab Green Technol GREENTEC, BR-21941909 Rio De Janeiro, RJ, Brazil
[3] PETROBRAS Res & Dev Ctr CENPES, Div Geochem, BR-21941915 Rio De Janeiro, RJ, Brazil
[4] Univ Estadual Campinas, Inst Chem, ThoMSon Mass Spectrometry Lab, BR-13083970 Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
STABLE-ISOTOPE-RATIO; ACETIC-ACID; CHROMATOGRAPHY; C-13/C-12; LIQUID; AUTHENTICITY; CHALLENGES; GUIDELINES; METHANOL; IRMS;
D O I
10.1002/rcm.7298
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RationaleBrazil is the largest producer of sugar cane bioethanol in the world. Isotope ratio mass spectrometry (IRMS) is the technique of choice to certify the origin/raw materials for ethanol production, but the lack of certified reference materials (CRMs) for accurate measurements of C-13 values traceable to Vienna Pee Dee Belemnite (VPDB), the international zero point for C-13/C-12 measurements, certified and compatible with gas chromatography (GC)/IRMS instruments may compromise the accuracy of C-13 determinations. MethodsWe evaluated the influence of methods for the calibration and normalization of raw C-13 values of ethanol samples. Samples were analyzed by GC/C/IRMS using two different GC columns. Different substances were used as isotopic standards for the working gas calibration. The C-13 values obtained with the three methods of normalization were statistically compared with those obtained with elemental analyzer (EA)/IRMS, since the C-13 results obtained using EA are traceable to VPDB via the NBS 22 reference material. ResultsIt was observed that both the isotopic reference material for CO2 calibration and the GC column have a major effect on the C-13 measurements, leading to a bias of almost 2-3 in the C-13 values. All three methods of normalization were equivalent in performance, enabling an improvement in the GC/C/IRMS accuracy, compared with the EA/IRMS reference values for the samples. ConclusionsAll the methods of CO2 calibration, chromatography and normalization presented in this work demonstrated several sources of traceability and accuracy loss for the determination of C-13 values in ethanol fuel samples by GC/C/IRMS. This work has also shown the importance of using proper CRMs traceable to VPBD that should be compatible and certified using GC/C/IRMS, ideally in a wide range of C-13 values. This is important not only for bioethanol fuel samples, but also for many analytes commonly analyzed by IRMS. Copyright (c) 2015 John Wiley & Sons, Ltd.
引用
收藏
页码:1938 / 1946
页数:9
相关论文
共 42 条
[1]   Tequila authenticity assessment by headspace SPME-HRGC-IRMS analysis of 13C/12C and 18O/16O ratios of ethanol [J].
Aguilar-Cisneros, BO ;
López, MG ;
Richling, E ;
Heckel, F ;
Schreier, P .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2002, 50 (26) :7520-7523
[2]   Gas chromatography/isotope ratio mass spectrometry: Analysis of methanol, ethanol and acetic acid by direct injection of aqueous alcoholic and acetic acid samples [J].
Ai, Guomin ;
Sun, Tong ;
Dong, Xiuzhu .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2014, 28 (15) :1674-1682
[3]  
[Anonymous], RENEWABLE SUSTAINABL
[4]  
[Anonymous], 2004, NIST SPECIAL PUBLICA
[5]  
[Anonymous], 2003, PREP CAL CURV GUID B
[6]   Use of isotope ratio mass spectrometry to detect doping with oral testosterone undecanoate:: Inter-individual variability of 13C/12C ratio [J].
Baume, N ;
Saudan, C ;
Desmarchelier, A ;
Strahm, E ;
Sottas, PE ;
Bagutti, C ;
Cauderay, M ;
Schumacher, YO ;
Manyin, P ;
Saugy, M .
STEROIDS, 2006, 71 (05) :364-370
[7]  
BIPM LEC, 2008, JCGM, V100, DOI DOI 10.1373/CLINCHEM.2003.030528
[8]   Assessment of international reference materials for isotope-ratio analysis (IUPAC Technical Report) [J].
Brand, Willi A. ;
Coplen, Tyler B. ;
Vogl, Jochen ;
Rosner, Martin ;
Prohaska, Thomas .
PURE AND APPLIED CHEMISTRY, 2014, 86 (03) :425-467
[9]  
Brogio J. R., 2009, THESIS UFRJ EQ
[10]   Isotope ratio mass spectrometry coupled to liquid and gas chromatography for wine ethanol characterization [J].
Cabanero, Ana I. ;
Recio, Jose L. ;
Ruperez, Mercedes .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (20) :3111-3118