From mono- to multicomponent methods in UV-VIS spectrophotometric and fluorimetric quantitative analysis e A review

被引:14
作者
Cerda, Victor [1 ]
Phansi, Piyawan [2 ]
Ferreira, Sergio [3 ,4 ]
机构
[1] Sciware Syst SL, Bunyola 07193, Spain
[2] Thepsatri Rajabhat Univ, Fac Sci & Technol, Dept Chem, Lopburi 15000, Thailand
[3] Univ Fed Bahia, Inst Quim, Campus Ondina, BR-40170270 Salvador, BA, Brazil
[4] Univ Fed Bahia, Inst Nacl Ciencia & Tecnol, Energia & Ambiente, INCT, BR-40170115 Salvador, BA, Brazil
关键词
Multicomponent analysis; Spectrometry; Fluorimetry; FLOW-INJECTION ANALYSIS; SIMULTANEOUS RESOLUTION; CHROMATOGRAPHIC PEAKS; LIQUID-CHROMATOGRAPHY; CURVE RESOLUTION; PHENOL COMPOUNDS; MIXTURES; METALS; WATERS;
D O I
10.1016/j.trac.2022.116772
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a review of different methods used for the simultaneous determination of several com-ponents through spectrophotometric and fluorimetric measurements is carried out including derivative methods. Several methods are described, like multilinear regression analysis and partial least squares, as well as some other for non-linear systems, like the Gauss-Newton, simplex and neural network methods. The effect of the contribution of unknown species has been considered. A novel approach related with the simultaneous determination of a catalyst and an activator or inhibitor has been included. Several manual and automated methods using flow techniques are described, including the resolution of over-lapped HPLC peaks. (c) 2022 Elsevier B.V. All rights reserved.
引用
收藏
页数:14
相关论文
共 41 条
[1]  
Ahmad Iqbal., 2019, EXCIPIENTS RELAT MET, V44, P379
[2]   DETERMINATION OF PRIORITY POLLUTANT PHENOLS BY ISOCRATIC HPLC [J].
ALARCON, P ;
BUSTOS, A ;
CANAS, B ;
ANDRES, MD ;
POLO, LM .
CHROMATOGRAPHIA, 1987, 24 :613-616
[3]   WinMLR, a software program for the simultaneous determination of several components in mixtures using multilinear regression analysis [J].
Becerra, Eduardo ;
Danchana, Kaewta ;
Cerda, Victor .
TALANTA, 2020, 213
[4]   DIODE-ARRAY DETECTORS IN FLOW-INJECTION ANALYSIS - MIXTURE RESOLUTION BY MULTI-WAVELENGTH ANALYSIS [J].
BLANCO, M ;
GENE, J ;
ITURRIAGA, H ;
MASPOCH, S ;
RIBA, J .
TALANTA, 1987, 34 (12) :987-993
[5]   Optimization using the gradient and simplex methods [J].
Cerda, Victor ;
Cerda, Juan Luis ;
Idris, Abubakr M. .
TALANTA, 2016, 148 :641-648
[6]   APPLICATION OF MULTICOMPONENT ANALYSIS TO THE SIMULTANEOUS RESOLUTION OF PHENOL COMPOUNDS IN MIXTURES .2. DEVELOPMENT OF A CLOSED-CIRCUIT EXTRACTION, ENRICHMENT AND BACK-EXTRACTION SYSTEM [J].
CLADERA, A ;
GOMEZ, E ;
ESTELA, JM ;
CERDA, V .
ANALYTICA CHIMICA ACTA, 1992, 267 (01) :103-109
[7]   APPLICATION OF MULTICOMPONENT ANALYSIS TO THE SIMULTANEOUS RESOLUTION OF PHENOL COMPOUNDS IN MIXTURES .1. DEVELOPMENT OF THE CALCULATION METHODS AND EXPERIMENTAL METHODOLOGY [J].
CLADERA, A ;
GOMEZ, E ;
ESTELA, JM ;
CERDA, V .
ANALYTICA CHIMICA ACTA, 1992, 267 (01) :95-102
[8]   Resolution of highly overlapping differential pulse anodic stripping voltammetric signals using multicomponent analysis and neural networks [J].
Cladera, A ;
Alpizar, J ;
Estela, JM ;
Cerda, V ;
Catasus, M ;
Lastres, E ;
Garcia, L .
ANALYTICA CHIMICA ACTA, 1997, 350 (1-2) :163-169
[9]   MULTICOMPONENT ANALYSIS OF HIGHLY OVERLAPPED HPLC PEAKS USING MULTIWAVELENGTH DIODE-ARRAY DETECTION [J].
CLADERA, A ;
GOMEZ, E ;
ESTELA, JM ;
CERDA, V .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1992, 30 (11) :453-458
[10]   COMPUTER METHOD FOR THE SIMULTANEOUS KINETIC DETERMINATION OF COMPOUNDS IN MIXTURES BASED ON THE USE OF DIODE-ARRAY SPECTROPHOTOMETRY [J].
CLADERA, A ;
GOMEZ, E ;
ESTELA, JM ;
CERDA, V ;
CERDA, JL .
ANALYTICA CHIMICA ACTA, 1993, 272 (02) :339-344