Dynamic analysis of impact in swing-through crutch gait using impulsive and continuous contact models

被引:17
作者
Font-Llagunes, Josep M. [1 ,2 ]
Barjau, Ana [1 ,2 ]
Pamies-Vila, Rosa [1 ,2 ]
Koevecses, Jozsef [3 ,4 ]
机构
[1] Univ Politecn Cataluna, Dept Mech Engn, E-08028 Barcelona, Catalunya, Spain
[2] Univ Politecn Cataluna, Biomed Engn Res Ctr, E-08028 Barcelona, Catalunya, Spain
[3] McGill Univ, Dept Mech Engn, Montreal, PQ H3A 2K6, Canada
[4] McGill Univ, Ctr Intelligent Machines, Montreal, PQ H3A 2K6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Biomechanics; Human locomotion; Contact dynamics; Impact; MULTIBODY SYSTEMS; MECHANICAL WORK; ELBOW CRUTCHES; ASSISTED GAIT; HUMAN WALKING; ENERGY-COST; LOCOMOTION; JOINT; FOOT; INDIVIDUALS;
D O I
10.1007/s11044-011-9300-9
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
The dynamics associated with the impact of the crutch with the ground is an important topic of research, since this is known to be the main cause of mechanical energy loss during swing-through gait. In this work, a multibody system representing a subject walking with crutches is used to investigate the behavior of two different contact models, impulsive and continuous, used for impact analysis. In the impulsive (discrete) approach, the impact interval is considered to be negligible and, therefore, the system configuration is constant. The postimpact state is directly obtained from the preimpact one through algebraic equations. In the continuous approach, the stiffness and dissipation characteristics of the contact surfaces are modeled through nonlinear springs and dampers. The equations of motion are integrated during the impact time interval to obtain the postimpact state, which, in principle, can differ from that obtained by means of the impulsive approach. Although both approaches have been widely used in the field of biomechanics, we have not found any comparative study in the existing literature justifying the model chosen for impact analysis. In this work, we present detailed numerical results and discussions to investigate several dynamic and energetic features associated with crutch impact. Based on the results, we compare the implications of using one contact model or the other.
引用
收藏
页码:257 / 282
页数:26
相关论文
共 45 条
[1]   The advantages of a rolling foot in human walking [J].
Adamczyk, Peter G. ;
Collins, Steven H. ;
Kuo, Arthur D. .
JOURNAL OF EXPERIMENTAL BIOLOGY, 2006, 209 (20) :3953-3963
[2]  
Agullo Batlle J., 1991, MECH MACH THEORY, V26, P656
[3]  
[Anonymous], CONTACT MECH
[4]   Development of an asymptotic modeling methodology for tibio-femoral contact in multibody dynamic simulations of the human knee joint [J].
Argatov, Ivan .
MULTIBODY SYSTEM DYNAMICS, 2012, 28 (1-2) :3-20
[5]   Termination conditions for three-dimensional inelastic collisions in multibody systems [J].
Batlle, JA .
INTERNATIONAL JOURNAL OF IMPACT ENGINEERING, 2001, 25 (07) :615-629
[6]   The sliding velocity flow of rough collisions in multibody systems [J].
Batlle, JA .
JOURNAL OF APPLIED MECHANICS-TRANSACTIONS OF THE ASME, 1996, 63 (03) :804-809
[7]   Multibody dynamic simulation of knee contact mechanics [J].
Bei, YH ;
Fregly, BJ .
MEDICAL ENGINEERING & PHYSICS, 2004, 26 (09) :777-789
[8]   Dynamics and Energetics of Impacts in Crutch Walking [J].
Carpentier, Clement ;
Font-Llagunes, Josep M. ;
Koevecses, Jozsef .
JOURNAL OF APPLIED BIOMECHANICS, 2010, 26 (04) :473-483
[9]   A three-dimensional passive-dynamic walking robot with two legs and knees [J].
Collins, SH ;
Wisse, M ;
Ruina, A .
INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 2001, 20 (07) :607-615
[10]   A force-based approach for joint efforts estimation during the double support phase of gait [J].
Cuadrado, Javier ;
Pamies-Vila, Rosa ;
Lugris, Urbano ;
Javier Alonso, F. .
IUTAM SYMPOSIUM ON HUMAN BODY DYNAMICS, 2011, 2 :26-34