Thermal characteristics of a helium-free superconducting magnet system for a fast-ramping heavy-ion synchrotron

被引:11
作者
Yang, Ye [1 ]
Mizushima, Kota [1 ]
Matsuba, Shunya [1 ]
Fujimoto, Tetsuya [2 ]
Noda, Etsuo [1 ]
Urata, Masami [1 ]
Shirai, Toshiyuki [1 ]
Takayama, Shigeki [3 ]
Amano, Saki [3 ]
Orikasa, Tomofumi [3 ]
机构
[1] Natl Inst Quantum Sci & Technol QST, Dept Accelerator & Med Phys, 4-9-1 Anagawa,Inage Ku, Chiba, Chiba 2638555, Japan
[2] Accelerator Engn Corp, 4-9-1 Anagawa,Inage Ku, Chiba, Chiba 2630043, Japan
[3] Toshiba Energy Syst & Solut Corp, 2-4 Suehiro Cho,Tsurumi Ku, Yokohama, Kanagawa 2300045, Japan
关键词
Superconducting magnet; Heavy-ion therapy; Conduction-cooling; Cryocooler; AC loss; Magnetization; Eddy current; Iron loss; Dynamic simulation; ROTATING-GANTRY; HYSTERESIS; PARAMETERS; DESIGN;
D O I
10.1016/j.cryogenics.2022.103524
中图分类号
O414.1 [热力学];
学科分类号
摘要
A compact synchrotron has been proposed for the next generation heavy-ion therapy system at the National Institutes for Quantum Science and Technology (QST). In this synchrotron, four 90-degree superconducting bending magnets designed on the basis of the superconducting magnet for the rotating-gantry currently operated at QST are adopted to achieve a compact size. These NbTi superconducting bending magnets are conduction-cooled by several Gifford-McMahon (GM) cryocoolers and are designed to generate both the dipole field of 3.5 T and the quadrupole field of 1.5 T/m to operate at a ramp rate of 0.7 T/s. It is a challenge to remove the heat generated from AC losses at such a fast ramp rate, and keep the superconducting magnets from quenching during the continuous operation without using liquid helium. In this paper, we studied the feasibility for realizing a fastramping synchrotron by using a helium-free superconducting magnet system for heavy-ion therapy. Using the numerical models, we estimated the AC losses including eddy current loss in mechanical structures, iron loss and loss in superconductor to be about 212 J in a cycle duration of 20 s for each 90-degree superconducting bending magnet, and it was possible to eliminate that amount of AC losses by using GM cryocoolers. To validate the transient temperature rising during the continuous operation, a dynamic simulation was performed using the estimated AC losses as input, and the peak temperature at thermal equilibrium was evaluated to be lower than 5 K for a practical operation scenario of heavy-ion therapy irradiation.
引用
收藏
页数:11
相关论文
共 35 条
[21]   MAGNETIC-PERMEABILITY OF THE IRON YOKE IN HIGH-FIELD SUPERCONDUCTING MAGNETS [J].
KAWABATA, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 329 (1-2) :1-8
[22]   Cryogenic system for COMET experiment at J-PARC [J].
Ki, Taekyung ;
Yoshida, Makoto ;
Yang, Ye ;
Ogitsu, Toru ;
Iio, Masami ;
Makida, Yasuhiro ;
Okamura, Takahiro ;
Mihara, Satoshi ;
Nakamoto, Tatsushi ;
Sugano, Michinaka ;
Sasaki, Ken-ichi .
CRYOGENICS, 2016, 77 :25-35
[23]   EDDY CURRENTS - THEORY AND APPLICATIONS [J].
KRIEZIS, EE ;
TSIBOUKIS, TD ;
PANAS, SM ;
TEGOPOULOS, JA .
PROCEEDINGS OF THE IEEE, 1992, 80 (10) :1559-1589
[24]   On the parameter identification and application of the Jiles-Atherton hysteresis model for numerical modelling of measured characteristics [J].
Lederer, D ;
Igarashi, H ;
Kost, A ;
Honma, T .
IEEE TRANSACTIONS ON MAGNETICS, 1999, 35 (03) :1211-1214
[25]   Concept Design of a Superconducting Magnet for a Compact Heavy-Ion Synchrotron [J].
Mizushima, Kota ;
Yang, Ye ;
Fujimoto, Tetsuya ;
Iwata, Yoshiyuki ;
Matsuba, Shunya ;
Abe, Yasushi ;
Noda, Etsuo ;
Urata, Masami ;
Shirai, Toshiyuki ;
Orikasa, Tomofumi ;
Takayama, Shigeki ;
Amano, Saki ;
Nakanishi, Kosuke ;
Hirata, Yutaka .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2022, 32 (06)
[26]  
Ponomarev P, 2016, 2016 XXII INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), P1657, DOI 10.1109/ICELMACH.2016.7732746
[27]   Jiles-Atherton Magnetic Hysteresis Parameters Identification [J].
Pop, N. C. ;
Caltun, O. F. .
ACTA PHYSICA POLONICA A, 2011, 120 (03) :491-496
[28]  
Russenschuck S, 2010, FIELD COMPUTATION FOR ACCELERATOR MAGNETS: ANALYTICAL AND NUMERICAL METHODS FOR ELECTROMAGNETIC DESIGN AND OPTIMIZATION, P1, DOI 10.1002/9783527635467
[29]  
Schnizer P., 2017, Advanced Mutlipoles for Accelerator Magnets: Theoretical Analysis and Their Measurement
[30]  
Sumitomo Heavy Industries/Cryogenics Group, RDE 418D4 4K CRYOCOO