Optimal Integration of Phasor Measurement Units in Power Systems Considering Conventional Measurements

被引:61
作者
Azizi, S. [1 ]
Gharehpetian, G. B. [2 ]
Dobakhshari, A. Salehi [3 ]
机构
[1] Univ Tehran, Sch Elect & Comp Engn, Coll Engn, Tehran 14395515, Iran
[2] Amirkabir Univ Technol, Dept Elect Engn, Tehran 158754413, Iran
[3] Sharif Univ Technol, Dept Elect Engn, Tehran 1136511155, Iran
关键词
Contingency; integer linear programming (ILP); observability; optimal PMU placement (OPP); phasor measurement unit (PMU); OPTIMAL PMU PLACEMENT; STATE ESTIMATION; OBSERVABILITY; FORMULATION; ALGORITHM; SEARCH;
D O I
10.1109/TSG.2012.2213279
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents an integer linear programming (ILP) framework for the optimal placement of phasor measurement units (PMUs), in the presence of conventional measurements. Furthermore, by the proposed method, the power system remains completely observable during all possible single contingencies for lines and measurement devices. In doing so, the potential of circuit equations associated with both PMUs and conventional measurements as well as the network topology are fully utilized by a system of equations to reach the minimum possible numbers of required PMUs. The limitation of communication channels is also taken into account in the proposed ILP-based framework. The method is implemented on several IEEE test systems which have already been equipped with conventional measurements. The comparison between obtained results of the proposed method and those of other methods reveals its superiority in the modeling of robust PMU placement problem (OPP) in the presence of conventional measurements. As such, a smooth transition from the SCADA-based monitoring system to the PMU-dominated WAMS is ensured. Moreover, this method is successfully applied on three large-scale test systems, which demonstrates it can effectively be employed for robust OPP in realistic power systems.
引用
收藏
页码:1113 / 1121
页数:9
相关论文
共 27 条
  • [1] A Unified Approach for the Optimal PMU Location for Power System State Estimation
    Abbasy, Nabil H.
    Ismail, Hanafy Mahmoud
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2009, 24 (02) : 806 - 813
  • [2] Contingency-Constrained PMU Placement in Power Networks
    Aminifar, Farrokh
    Khodaei, Amin
    Fotuhi-Firuzabad, Mahmud
    Shahidehpour, Mohammad
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2010, 25 (01) : 516 - 523
  • [3] [Anonymous], 1997, ASS APPL BEN PHAS ME
  • [4] Optimal PMU Placement by an Equivalent Linear Formulation for Exhaustive Search
    Azizi, Sadegh
    Dobakhshari, Ahmad Salehi
    Sarmadi, S. Arash Nezam
    Ranjbar, Ali Mohammad
    [J]. IEEE TRANSACTIONS ON SMART GRID, 2012, 3 (01) : 174 - 182
  • [5] POWER-SYSTEM OBSERVABILITY WITH MINIMAL PHASOR MEASUREMENT PLACEMENT
    BALDWIN, TL
    MILI, L
    BOISEN, MB
    ADAPA, R
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 1993, 8 (02) : 707 - 715
  • [6] m-k robust observability in state estimation
    Castillo, Enrique
    Conejo, Antonio J.
    Pruneda, Rosa E.
    Solares, Cristina
    Menendez, Jose M.
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2008, 23 (02) : 296 - 305
  • [7] Optimal placement of phasor measurement units for power system observability
    Chakrabarti, Saikat
    Kyriakides, Elias
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2008, 23 (03) : 1433 - 1440
  • [8] Placement of Synchronized Measurements for Power System Observability
    Chakrabarti, Saikat
    Kyriakides, Elias
    Eliades, Demetrios G.
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (01) : 12 - 19
  • [9] Cho KS, 2001, 2001 IEEE POWER ENGINEERING SOCIETY WINTER MEETING, CONFERENCE PROCEEDINGS, VOLS 1-3, P258, DOI 10.1109/PESW.2001.917045
  • [10] OBSERVABILITY METHODS AND OPTIMAL METER PLACEMENT
    CLEMENTS, KA
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 1990, 12 (02) : 88 - 93