Mechanism Study of Capacitance Method for Steam-injecting Dryness Measuring

被引:0
作者
Han, Jian [1 ]
He, Xue Lan [1 ]
Mou, Hai Wei [1 ]
机构
[1] Northeast Petr Univ, Coll Elect Sci, Daqing 163318, Peoples R China
来源
PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON ELECTRONIC & MECHANICAL ENGINEERING AND INFORMATION TECHNOLOGY (EMEIT-2012) | 2012年 / 23卷
关键词
Steam quality; In-line measurement; Dielectric constant; Capacitor;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Regarding the importance of wet saturated steam dryness measurement, at the same temperature and pressure the dielectric constant of water is much greater than that of steam. When the wet steam flows by the capacitive sensor, the sensor capacitance changes with the steam wetness. A new method that barrel capacitor is presented to provide real-time and in-line measurement of steam quality. According to the calculation results and the theory data calibration, thus the present method solves the problems associated with industrial steam boilers and steam injection wells dryness in-line measurement.
引用
收藏
页数:4
相关论文
共 5 条
[1]  
[Anonymous], NING DE LIANG NEW CA
[2]  
[Anonymous], 19111997 ASME PTC
[3]  
[Anonymous], NIST ASME STEAM PROP
[4]  
Cengel Y. A., 2006, Thermodynamics: An Engineering Approach
[5]  
Kraszewski A.W., 1996, MICROWAVE AQUAMETRY