Direct Detection of Acidity, Alkalinity, and pH with Membrane Electrodes

被引:34
作者
Crespo, Gaston A. [1 ]
Afshar, Majid Ghahraman [1 ]
Bakker, Eric [1 ]
机构
[1] Univ Geneva, Dept Inorgan Analyt & Appl Chem, CH-1211 Geneva, Switzerland
基金
瑞士国家科学基金会;
关键词
ION-SELECTIVE ELECTRODES; EXCHANGE MEMBRANES; SUPPORTING ELECTROLYTE; POLYMERIC MEMBRANES; BASE TITRATIONS; WEAK ACIDS; CHRONOPOTENTIOMETRY; DIFFUSION; VOLTAMMETRY; WATER;
D O I
10.1021/ac302868u
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical sensing protocol based on supported liquid ion-selective membranes for the direct detection of total alkalinity of a sample that contains a weak base such as Tris (pK(a) = 8.2) is presented here for the first time. Alkalinity is determined by imposing a defined flux of hydrogen ions from the membrane to the sample with an applied current. The transition time at which the base species at the membrane-sample interface depletes owing to diffusion limitation is related to sample alkalinity in this chronopotentiometric detection mode. The same membrane is shown to detect pH (by zero current potentiometry) and acidity and alkalinity (by chronopotentiometry at different current polarity). This principle may become a welcome tool for the in situ determination of these characteristics in complex samples such as natural waters.
引用
收藏
页码:10165 / 10169
页数:5
相关论文
共 38 条
[1]   CHRONOPOTENTIOMETRIC STUDIES AT SOLID ELECTRODES [J].
ADAMS, RN ;
MCCLURE, JH ;
MORRIS, JB .
ANALYTICAL CHEMISTRY, 1958, 30 (04) :471-475
[2]   Direct Ion Speciation Analysis with Ion-Selective Membranes Operated in a Sequential Potentiometric/Time Resolved Chronopotentiometric Sensing Mode [J].
Afshar, Majid Ghahraman ;
Crespo, Gaston A. ;
Bakker, Eric .
ANALYTICAL CHEMISTRY, 2012, 84 (20) :8813-8821
[3]  
[Anonymous], 2001, ELECTROCHEMICAL METH
[4]   Comprehensive Formulation of Titration Curves for Complex Acid-Base Systems and Its Analytical Implications [J].
Asuero, Agustin G. ;
Michalowski, Tadeusz .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2011, 41 (02) :151-187
[5]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[6]  
Bard A. J., 1964, ANAL CHEM, V36, P70
[8]   Operational limits of controlled current coulometry with ion-selective polymeric membranes [J].
Bhakthavatsalam, Vishnupriya ;
Bakker, Eric .
ELECTROANALYSIS, 2008, 20 (03) :225-232
[9]   Selective coulometric release of ions from ion selective polymeric membranes for calibration-free titrations [J].
Bhakthavatsalam, Vishnupriya ;
Shvarev, Alexey ;
Bakker, Eric .
ANALYST, 2006, 131 (08) :895-900
[10]   STEADY-STATE VOLTAMMETRY OF STRONG AND WEAK ACIDS WITH AND WITHOUT SUPPORTING ELECTROLYTE [J].
CISZKOWSKA, M ;
STOJEK, Z ;
MORRIS, SE ;
OSTERYOUNG, JG .
ANALYTICAL CHEMISTRY, 1992, 64 (20) :2372-2377