Analysis of priority pollutants in environmental samples by on-line supercritical fluid chromatography cleanup-cryo-trap-gas chromatography-mass spectrometry

被引:15
作者
Fuoco, R [1 ]
Ceccarini, A [1 ]
Onor, M [1 ]
Marrara, L [1 ]
机构
[1] Univ Pisa, Dipartimento Chim & Chim Ind, I-56126 Pisa, Italy
关键词
environmental analysis; sample handling; sediments; water analysis; polynuclear aromatic hydrocarbons; polychlorinated biphenyls; organochlorine compounds; pesticides;
D O I
10.1016/S0021-9673(99)00346-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
On-line coupling of a supercritical fluid chromatography cleanup system with gas chromatography-mass spectrometry (GC-MS) was performed using a custom-made cryo-trap cell. The cleanup system was based on a high-performance liquid chromatography (HPLC) column packed with about 100 mg of Florisil. This coupling considerably reduces the effect of high boiling compounds on the chromatographic efficiency in the determination of organic pollutants in environmental samples. Moreover, it enables multistep elution from the cleanup column by the addition of a suitable supercritical CO(2) modifier, which was performed automatically. The system was proved for the determination of polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls in sediment reference material samples, and in spiked sea-water samples. In particular, a three-step elution of selected PAHs, which were the most retained, from the Florisil column was performed at 40 degrees C and 25 MPa, at a supercritical CO(2) flow of 0.4 ml/min for a total elution time of 10 min. The recovery of all contaminants considered was always better than 75%, with a relative standard deviation of about 15%. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:387 / 393
页数:7
相关论文
共 13 条
  • [1] SOLID-PHASE MICROEXTRACTION COUPLED TO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    CHEN, J
    PAWLISZYN, JB
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (15) : 2530 - 2533
  • [2] DETERMINATION OF POLYCHLOROBIPHENYLS IN ENVIRONMENTAL-SAMPLES FROM ANTARCTICA
    FUOCO, R
    COLOMBINI, MP
    ABETE, C
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1994, 55 (1-4) : 15 - 25
  • [3] Supercritical fluid extraction combined on-line with cold-trap gas chromatography mass spectrometry
    Fuoco, R
    Ceccarini, A
    Onor, M
    Lottici, S
    [J]. ANALYTICA CHIMICA ACTA, 1997, 346 (01) : 81 - 86
  • [4] FUOCO R, 1991, ANN CHIM-ROME, V81, P383
  • [5] Detectability enhancement by the use of large-volume injections in gas chromatography cryotrapping Fourier transform infrared spectrometry
    Hankemeier, T
    vanderLaan, HTC
    Vreuls, JJ
    Vredenbregt, MJ
    Visser, T
    Brinkman, UAT
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1996, 732 (01) : 75 - 84
  • [6] QUANTITATIVE-ANALYSIS USING DIRECTLY COUPLED SUPERCRITICAL FLUID EXTRACTION CAPILLARY GAS-CHROMATOGRAPHY (SFE-GC) WITH A CONVENTIONAL SPLIT SPLITLESS INJECTION PORT
    HAWTHORNE, SB
    MILLER, DJ
    LANGENFELD, JJ
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1990, 28 (01) : 2 - 8
  • [7] INTEGRATED ANALYSIS OF SOLID SAMPLES BY ONLINE SUPERCRITICAL FLUID EXTRACTION GAS-CHROMATOGRAPHY
    LOHLEIT, M
    BACHMANN, K
    [J]. JOURNAL OF CHROMATOGRAPHY, 1990, 505 (01): : 227 - 235
  • [8] MCCABE T, 1989, HRC-J HIGH RES CHROM, V12, P517
  • [9] TRACE-LEVEL ANALYSIS OF MICROPOLLUTANTS IN AQUEOUS SAMPLES USING GAS-CHROMATOGRAPHY WITH ONLINE SAMPLE ENRICHMENT AND LARGE-VOLUME INJECTION
    MOL, HGJ
    JANSSEN, HGM
    CRAMERS, CA
    VREULS, JJ
    BRINKMAN, UAT
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1995, 703 (1-2) : 277 - 307
  • [10] MOL HGJ, 1996, J HIGH RES CHROMATOG, V19, P69