Radiotherapy fiber dosimeter probes based on silver-only coated hollow glass waveguides

被引:13
作者
Darafsheh, Arash [1 ]
Melzer, Jeffrey E. [2 ]
Harrington, James A. [2 ]
Kassaee, Alireza [3 ]
Finlay, Jarod C. [3 ]
机构
[1] Washington Univ, Sch Med, Dept Radiat Oncol, St Louis, MO 63130 USA
[2] Rutgers State Univ, Dept Mat Sci & Engn, Piscataway, NJ USA
[3] Univ Penn, Dept Radiat Oncol, Philadelphia, PA 19104 USA
关键词
radiation therapy; dosimetry; hollow waveguide; optical fiber; Cerenkov radiation; spectroscopy; PLASTIC SCINTILLATION DETECTORS; CERENKOV RADIATION; OPTICAL-FIBERS; LIGHT-EMISSION; ELECTRON; PHOTON; SENSOR; BEAMS; ARRAY;
D O I
10.1117/1.JBO.23.1.015006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Manifestation of Cerenkov radiation as a contaminating signal is a significant issue in radiation therapy dose measurement by fiber-coupled scintillator dosimeters. To enhance the scintillation signal transmission while minimizing Cerenkov radiation contamination, we designed a fiber probe using a silver-only coated hollow waveguide (HWG). The HWG with scintillator inserted in its tip, embedded in tissue-mimicking phantoms, was irradiated with clinical electron and photon beams generated by a medical linear accelerator. Optical spectra of the irradiated tip were taken using a fiber spectrometer, and the signal was deconvolved with a linear fitting algorithm. The resultant decomposed spectra of the scintillator with and without Cerenkov correction were in agreement with measurements performed by a standard electron diode and ion chamber for electron and photon beam dosimetry, respectively, indicating the minimal effect of Cerenkov contamination in the HWG-based dosimeter. Furthermore, compared with a silver/dielectric-coated HWG fiber dosimeter design, we observed higher signal transmission in the design based on the use of silver-only HWG. (C) 2018 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:7
相关论文
共 59 条
[1]   Monte Carlo simulations support non-Cerenkov radioluminescence production in tissue [J].
Ackerman, Nicole L. ;
Boschi, Federico ;
Spinelli, Antonello E. .
JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (08)
[2]  
[Anonymous], MED PHYS
[3]  
[Anonymous], 1958, CERENKOV RAD ITS APP
[4]  
[Anonymous], MED PHYS
[5]  
[Anonymous], 2015, P SPIE
[6]  
[Anonymous], 2004, SPIE
[7]  
[Anonymous], 2013, THESIS U N CAROLINA
[8]  
[Anonymous], P SPIE
[9]  
[Anonymous], P SPIE
[10]   Cerenkov emission induced by external beam radiation stimulates molecular fluorescence [J].
Axelsson, Johan ;
Davis, Scott C. ;
Gladstone, David J. ;
Pogue, Brian W. .
MEDICAL PHYSICS, 2011, 38 (07) :4127-4132